Lan-Fang Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lan-Fang Huang has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Fang-Qiu Guo
6 shared publicationsMing-Jian Wu
5 shared publicationsYi-Zeng Liang
5 shared publicationsXian-Jun Sun
4 shared publications- Fang-Qiu Guo
Central South University
3 shared publications Ke-Long Huang
3 shared publications
Latest Publications
- Open Access
Study of the Volatile Constituents in Radix Flemingiae Macrophyllae and a Substitute by Gas Chromatography-Mass Spectrometry and Chemometric Methods
A combined approach of subwindow factor analysis and spectral correlative chromatography was used to analyze the volatile components in Radix Flemingiae Macrophyllae and Flemingiae Latifolia Benth, one of its substitutes. After extraction by a water distillation method, the volatile components in Radix Flemingiae Macrophyllae and Flemingiae Latifolia Benth were detected by GC-MS. Then the qualitative and quantitative analysis of the volatile components in Radix Flemingiae Macrophyllae was completed with the help of subwindow factor analysis resolving two-dimensional original data into mass spectra and chromatograms. Sixty five of 82 separated constituents in the total ion chromatogram of the volatile components in Radix Flemingiae Macrophyllae were identified and quantified, accounting for about 88.79% of the total content. Then, spectral correlative chromatography was used to extract correlative constituents in Flemingiae Latifolia Benth. Fifty one correlative components were recognized in essential oil of Flemingiae Latifolia Benth. The result proves the combined approach is powerful in the analysis of complex herbal samples. The developed method can be used to compare the sameness and differences of Radix Flemingiae Macrophyllae and its substitutes and it can also be used for quality control of Radix Flemingiae Macrophyllae.
Open AccessStudy of the Volatile Constituents in Radix Flemingiae Macrophyllae and a Substitute by Gas Chromatography-Mass Spectrometry and Chemometric Methods
A combined approach of subwindow factor analysis and spectral correlative chromatography was used to analyze the volatile components in Radix Flemingiae Macrophyllae and Flemingiae Latifolia Benth, one of its substitutes. After extraction by a water distillation method, the volatile components in Radix Flemingiae Macrophyllae and Flemingiae Latifolia Benth were detected by GC-MS. Then the qualitative and quantitative analysis of the volatile components in Radix Flemingiae Macrophyllae was completed with the help of subwindow factor analysis resolving two-dimensional original data into mass spectra and chromatograms. Sixty five of 82 separated constituents in the total ion chromatogram of the volatile components in Radix Flemingiae Macrophyllae were identified and quantified, accounting for about 88.79% of the total content. Then, spectral correlative chromatography was used to extract correlative constituents in Flemingiae Latifolia Benth. Fifty one correlative components were recognized in essential oil of Flemingiae Latifolia Benth. The result proves the combined approach is powerful in the analysis of complex herbal samples. The developed method can be used to compare the sameness and differences of Radix Flemingiae Macrophyllae and its substitutes and it can also be used for quality control of Radix Flemingiae Macrophyllae.
- Open Access
Identification and Determination of Flavonoids in Astragali Radix by High Performance Liquid Chromatography Coupled with DAD and ESI-MS Detection
A method for the analysis of flavonoids in Astragali Radix by high-performance liquid chromatography (HPLC) combined with photodiode-array detection (DAD) and an electrospray ionization (ESI) - mass spectrometry (MS) was developed. After the samples were extracted with ethanol, the optimum separation conditions for these analytes were achieved using a gradient elution system and a 2.0 × 150 mm Shimadzu VP-ODS column. Eight flavonoids were identified to exist in Astragali Radix based on their characteristic UV data and mass spectra. The concentrations of three major components in this herb—ononin, calycosin and formononetin—were determined by LC/ESI-MS in positive selective ion monitoring (SIM) mode. The calibration curves were linear in the range of 0.9~180.0 μg·mL−1 for ononin, 1.8~360.0 μg·mL−1 for calycosin and 1.4~280 μg·mL−1 for formononetin, respectively. The limits of quantification (LOQ) and detection (LOD) were 0.9 μg· mL−1 and 0.2 μg mL−1 for ononin, 1.8 μg mL−1 and 0.5 μg·mL−1 for calycosin, 1.4 μg mL−1 and 0.5 μg·mL−1 for formononetin, respectively. The standard recoveries were between 95.4~104.7%. The developed method was proven to be useful for the quantitative and qualitative analysis of flavonoid constituents in various resources of Astragali Radix.
Open AccessIdentification and Determination of Flavonoids in Astragali Radix by High Performance Liquid Chromatography Coupled with DAD and ESI-MS Detection
A method for the analysis of flavonoids in Astragali Radix by high-performance liquid chromatography (HPLC) combined with photodiode-array detection (DAD) and an electrospray ionization (ESI) - mass spectrometry (MS) was developed. After the samples were extracted with ethanol, the optimum separation conditions for these analytes were achieved using a gradient elution system and a 2.0 × 150 mm Shimadzu VP-ODS column. Eight flavonoids were identified to exist in Astragali Radix based on their characteristic UV data and mass spectra. The concentrations of three major components in this herb—ononin, calycosin and formononetin—were determined by LC/ESI-MS in positive selective ion monitoring (SIM) mode. The calibration curves were linear in the range of 0.9~180.0 μg·mL−1 for ononin, 1.8~360.0 μg·mL−1 for calycosin and 1.4~280 μg·mL−1 for formononetin, respectively. The limits of quantification (LOQ) and detection (LOD) were 0.9 μg· mL−1 and 0.2 μg mL−1 for ononin, 1.8 μg mL−1 and 0.5 μg·mL−1 for calycosin, 1.4 μg mL−1 and 0.5 μg·mL−1 for formononetin, respectively. The standard recoveries were between 95.4~104.7%. The developed method was proven to be useful for the quantitative and qualitative analysis of flavonoid constituents in various resources of Astragali Radix.
- Open Access
Determination of the Volatile Constituents in Radix Flemingiae Philippinensis by GC-MS and a Heuristic Evolving Latent Projection Method
With the help of chemometric resolution methods, a technique for qualitative and quantitative determination of the volatile chemical constituents in Radix Flemingiae Philippinensis by chromatography-mass spectrometry was developed. After the overlapping chromatographic peaks were resolved into pure chromatograms and spectra using a heuristic evolving latent projections (HELP) method, qualitative analysis was performed by similarity search of the obtained pure mass spectrum of each component in the NIST library and the quantitative results were obtained by calculating the total two-way response volume. A total of 63 components were separated and 55 components were identified, accounting for 90.62% of the total content. The main components were farnesol isomer and β-caryophyllene, accounting for 31.33% and 12.60% of the total content, respectively. The obtained results can provide useful information for further study and development of Radix Flemingiae Philippinensis.
Open AccessDetermination of the Volatile Constituents in Radix Flemingiae Philippinensis by GC-MS and a Heuristic Evolving Latent Projection Method
With the help of chemometric resolution methods, a technique for qualitative and quantitative determination of the volatile chemical constituents in Radix Flemingiae Philippinensis by chromatography-mass spectrometry was developed. After the overlapping chromatographic peaks were resolved into pure chromatograms and spectra using a heuristic evolving latent projections (HELP) method, qualitative analysis was performed by similarity search of the obtained pure mass spectrum of each component in the NIST library and the quantitative results were obtained by calculating the total two-way response volume. A total of 63 components were separated and 55 components were identified, accounting for 90.62% of the total content. The main components were farnesol isomer and β-caryophyllene, accounting for 31.33% and 12.60% of the total content, respectively. The obtained results can provide useful information for further study and development of Radix Flemingiae Philippinensis.
- Open Access
Analysis of the Main Nucleosides in Cordyceps Sinensis by LC/ESI-MS
A sensitive, selective and reliable liquid chromatography-mass spectrometry coupled with electrospray ionization interface method for simultaneous separation and determination of thymine, adenine, adenosine and cordycepin in Cordyceps sinensis has been established. The optimum separation for these analytes was achieved using a gradient elution system and a 2.0 × 150 mm Shimadzu VP-ODS column. 2-Chloroadenosine was used as internal standard for this assay. [M+H]+ions at m/z 127, 136, 268, 252 and 302 were chosen and selective ion monitoring (SIM) mode was used for quantitative analysis of the four main nucleosides. The regression equations were linear in the range of 1.0–117.5 μg·mL-1 for thymine, 1.8-127.0 μg·mL-1 for adenine, 0.6-114.0 μg·mL-1 for adenosine and 0.5-107.5 μg·mL-1 for cordycepin. The limits of quantitation (LOQ) and detection (LOD) were 1.0 and 0.2 μg·mL-1 for thymine, 1.8 and 0.6 μg·mL-1 for adenine, 0.6 and 0.1 μg·mL-1 for adenosine and 0.5 and 0.1 μg·mL-1 for cordycepin, respectively. The recoveries of the four nucleosides ranged from 98.47 to 99.32%. The developed method was successfully used to determine nucleosides in Cordyceps sinensis from different sources.
Open AccessAnalysis of the Main Nucleosides in Cordyceps Sinensis by LC/ESI-MS
A sensitive, selective and reliable liquid chromatography-mass spectrometry coupled with electrospray ionization interface method for simultaneous separation and determination of thymine, adenine, adenosine and cordycepin in Cordyceps sinensis has been established. The optimum separation for these analytes was achieved using a gradient elution system and a 2.0 × 150 mm Shimadzu VP-ODS column. 2-Chloroadenosine was used as internal standard for this assay. [M+H]+ions at m/z 127, 136, 268, 252 and 302 were chosen and selective ion monitoring (SIM) mode was used for quantitative analysis of the four main nucleosides. The regression equations were linear in the range of 1.0–117.5 μg·mL-1 for thymine, 1.8-127.0 μg·mL-1 for adenine, 0.6-114.0 μg·mL-1 for adenosine and 0.5-107.5 μg·mL-1 for cordycepin. The limits of quantitation (LOQ) and detection (LOD) were 1.0 and 0.2 μg·mL-1 for thymine, 1.8 and 0.6 μg·mL-1 for adenine, 0.6 and 0.1 μg·mL-1 for adenosine and 0.5 and 0.1 μg·mL-1 for cordycepin, respectively. The recoveries of the four nucleosides ranged from 98.47 to 99.32%. The developed method was successfully used to determine nucleosides in Cordyceps sinensis from different sources.
- 1 April 2007
- Published by Elsevier in Analytica Chimica Acta
- Vol. 588 (2) , 216-223
Fingerprint developing of coffee flavor by gas chromatography–mass spectrometry and combined chemometrics methods
- 1 April 2007
- Published by Elsevier in Analytica Chimica Acta
- Vol. 588 (2) , 216-223
Fingerprint developing of coffee flavor by gas chromatography–mass spectrometry and combined chemometrics methods
- 1 August 2006
- Published by Elsevier in Analytica Chimica Acta
- Vol. 575 (2) , 236-245
Comparative analysis of the volatile components in cut tobacco from different locations with gas chromatography–mass spectrometry (GC–MS) and combined chemometric methods
- 1 August 2006
- Published by Elsevier in Analytica Chimica Acta
- Vol. 575 (2) , 236-245
Comparative analysis of the volatile components in cut tobacco from different locations with gas chromatography–mass spectrometry (GC–MS) and combined chemometric methods
- 1 August 2005
- Published by Springer Nature in Journal of Central South University of Technology
- Vol. 12 (4) , 430-436
Determination of constituents of essential oil from Angelica sinensis by gas chromatography — mass spectrometry
- 1 August 2005
- Published by Springer Nature in Journal of Central South University of Technology
- Vol. 12 (4) , 430-436
Determination of constituents of essential oil from Angelica sinensis by gas chromatography — mass spectrometry
- 29 October 2004
- Vol. 1054, 73-9
Comparison of the volatile constituents of Artemisia capillaris from different locations by gas chromatography-mass spectrometry and projection method.
The volatile chemical constituents of Artemisia capillaries (an important traditional Chinese medicine) were determined by gas chromatography-mass spectrometry (GC-MS) and sub-window factor analysis (SFA). Seventy-five components were separated and 43 of them were qualitatively and quantitatively determined, which represented about 89.03% of the total content. This profile was then used to identify and assess the consistency of the herb by using an orthogonal projection method. Four different sources of A. capillaries were analyzed and compared with each other. Among the components determined, there were 51 components coexisting in all samples although the relative peak areas of a few showed variations. It is the first time to apply orthogonal projection method to the comparison of different samples, and it reduces the burden of qualitative analysis as well as the subjectivity. The results showed a fair consistency in their GC-MS fingerprint. A. capillaris was distinguished from Artemisia sacrorum L., a possible substitute in traditional Chinese medicine by comparing the fingerprints with each other.
- 29 October 2004
- Vol. 1054, 73-9
Comparison of the volatile constituents of Artemisia capillaris from different locations by gas chromatography-mass spectrometry and projection method.
The volatile chemical constituents of Artemisia capillaries (an important traditional Chinese medicine) were determined by gas chromatography-mass spectrometry (GC-MS) and sub-window factor analysis (SFA). Seventy-five components were separated and 43 of them were qualitatively and quantitatively determined, which represented about 89.03% of the total content. This profile was then used to identify and assess the consistency of the herb by using an orthogonal projection method. Four different sources of A. capillaries were analyzed and compared with each other. Among the components determined, there were 51 components coexisting in all samples although the relative peak areas of a few showed variations. It is the first time to apply orthogonal projection method to the comparison of different samples, and it reduces the burden of qualitative analysis as well as the subjectivity. The results showed a fair consistency in their GC-MS fingerprint. A. capillaris was distinguished from Artemisia sacrorum L., a possible substitute in traditional Chinese medicine by comparing the fingerprints with each other.
- 24 September 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 380 (4) , 643-649
Simultaneous determination of L-arginine and its mono- and dimethylated metabolites in human plasma by high-performance liquid chromatography?mass spectrometry
A simple, fast, sensitive, and reproducible isocratic liquid chromatography–mass spectrometry (LC-MS) method coupled with an atmospheric pressure chemical ionization (APCI) interface for simultaneous separation and determination of L-arginine (ARG) and its methylated metabolites, N-monomethyl-L-arginine (MMA), N G ,N G -dimethylarginine (asymmetric dimethyl arginine, ADMA), and N G ,N′ G -dimethylarginine (symmetric dimethyl arginine, SDMA), in human plasma is presented. Sample pretreatment is not required other than deproteinization with 5-sulfosalicylic acid (5-SSA). Satisfactory chromatographic separation was achieved on a 2.0×150-mm Shimadzu VP-ODS column by using a mobile phase consisting of water/acetonitrile (90/10, v/v) containing 0.5% trifluoroacetic acid (TFA). Positive selective ion monitoring (SIM) mode was chosen for quantification of each analyte. The positively protonated molecular ions [M+H]+ of ARG, MMA, ADMA, and SDMA were monitored at m/z 175, 189, 203, and 203, respectively. L-Homoarginine was used as the internal standard (IS) for the assay. The limits of quantification (LOQs) were found to be 1.0 μmol L−1 for ARG, and 0.2 μmol L−1 for MMA, ADMA, and SDMA. The inter-assay precision and accuracy were in the range of 1.8–4.9% and −3.0–5.0%, respectively. The intra-assay precision and accuracy were in the order of 1.7–4.6 and −2.6–4.0%, respectively. The recoveries were between 90.0 and 106.6%. The levels of ARG, MMA, ADMA, and SDMA in human plasma were also determined using the developed method.
- 24 September 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 380 (4) , 643-649
Simultaneous determination of L-arginine and its mono- and dimethylated metabolites in human plasma by high-performance liquid chromatography?mass spectrometry
A simple, fast, sensitive, and reproducible isocratic liquid chromatography–mass spectrometry (LC-MS) method coupled with an atmospheric pressure chemical ionization (APCI) interface for simultaneous separation and determination of L-arginine (ARG) and its methylated metabolites, N-monomethyl-L-arginine (MMA), N G ,N G -dimethylarginine (asymmetric dimethyl arginine, ADMA), and N G ,N′ G -dimethylarginine (symmetric dimethyl arginine, SDMA), in human plasma is presented. Sample pretreatment is not required other than deproteinization with 5-sulfosalicylic acid (5-SSA). Satisfactory chromatographic separation was achieved on a 2.0×150-mm Shimadzu VP-ODS column by using a mobile phase consisting of water/acetonitrile (90/10, v/v) containing 0.5% trifluoroacetic acid (TFA). Positive selective ion monitoring (SIM) mode was chosen for quantification of each analyte. The positively protonated molecular ions [M+H]+ of ARG, MMA, ADMA, and SDMA were monitored at m/z 175, 189, 203, and 203, respectively. L-Homoarginine was used as the internal standard (IS) for the assay. The limits of quantification (LOQs) were found to be 1.0 μmol L−1 for ARG, and 0.2 μmol L−1 for MMA, ADMA, and SDMA. The inter-assay precision and accuracy were in the range of 1.8–4.9% and −3.0–5.0%, respectively. The intra-assay precision and accuracy were in the order of 1.7–4.6 and −2.6–4.0%, respectively. The recoveries were between 90.0 and 106.6%. The levels of ARG, MMA, ADMA, and SDMA in human plasma were also determined using the developed method.