FGFang-Qiu Guo

Fang-Qiu Guo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fang-Qiu Guo has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Essential Oil Composition of Osmanthus fragrans Varieties by GC-MS and Heuristic Evolving Latent Projections

    by Chun-Di Hu, Yi-Zeng Liang, Xiao-Ru Li, Fang-Qiu Guo, Mao-Mao Zeng, Liang-Xiao Zhang, Hong-Dong Li


    • 29 October 2004
      • Vol. 1054, 73-9

    Comparison of the volatile constituents of Artemisia capillaris from different locations by gas chromatography-mass spectrometry and projection method.

    by Fang-Qiu Guo, Yi-Zeng Liang, Cheng-Jian Xu, Lan-Fang Huang, Xiao-Ning Li

    The volatile chemical constituents of Artemisia capillaries (an important traditional Chinese medicine) were determined by gas chromatography-mass spectrometry (GC-MS) and sub-window factor analysis (SFA). Seventy-five components were separated and 43 of them were qualitatively and quantitatively determined, which represented about 89.03% of the total content. This profile was then used to identify and assess the consistency of the herb by using an orthogonal projection method. Four different sources of A. capillaries were analyzed and compared with each other. Among the components determined, there were 51 components coexisting in all samples although the relative peak areas of a few showed variations. It is the first time to apply orthogonal projection method to the comparison of different samples, and it reduces the burden of qualitative analysis as well as the subjectivity. The results showed a fair consistency in their GC-MS fingerprint. A. capillaris was distinguished from Artemisia sacrorum L., a possible substitute in traditional Chinese medicine by comparing the fingerprints with each other.


  • Identification of Structures of Nitrogen‐Containing Compounds in Crude Oils in Conjunction with Chemometric Resolution

    by Taiming Zhang, Yizeng Liang, Boyan Li, Hui Cui, Lanfang Huang, Fangqiu Guo, Chenxi Zhao

    A universal method was established for the systematically structural identification of nitrogen‐containing compounds in crude oils. Pre‐fractionation of the non‐hydrocarbons in a crude oil sample into 7 fractions was performed by di‐adsorption column chromatography using neutral aluminum oxide and silica gel; subsequent high‐resolution separation of individual components was achieved by using capillary column gas chromatography, and compound types were detected by mass spectrometer. The two‐dimensional data from the compounds in the fractions were further resolved by a chemometric method to obtained the deconvoluted chromatogram and mass spectrum of every compound, and then, the nitrogen‐containing compounds were identified in combination with the retention indices. This method could relieve the difficulty of classical analysis in identifying those species with very low contents or incompletely separation, particularly in the cases where the authentic standards were not available for addition into the unknown samples in order to reveal what indeed existed in them. The structures of 168 nitrogen‐containing compounds in a crude oil sample were determined by this method with satisfactory results.


    • 1 August 2004
      • Vol. 29  (8) , 762-4

    [Determination of adenosine and cordycepin in Cordyceps sinensis and C. militarris with HPLC-ESI-MS].

    by Lan-Fang Huang, Fang-Qiu Guo, Yi-Zeng Liang, Ben-Mei Chen

    HPLC-ESI-MS to establish a method for simultaneous determination of adenosine and cordycepin in Cordyceps sinensis and C. militarris. HPLC-ESI-MS method. An electrospray ionization (ESI) interface and selective ion monitoring (SIM) mode were used. The analytical column was a 2.0 mm x 150 mm Shimadzu VP - ODS column and the mobile phase was water (94%), methanol (5%) and formic acid (1%). 2-Chloroadenosine was used as internal standard for this assay. The regression equations and coefficient were Y = 0.134 6X + 0.001 29 (r = 0.998 4) for adenosine, Y = 0.216 4X + 0.021 5 (r = 0.999 1) for cordycepin. The liner range was 0.5 approximately 124.5 microg x mL(-1) and 0.5 approximately 136.5 microg x mL(-1) for adenosine and cordycepin, respectively. The average recoveries of adenosine and cordycepin were 95.8% and 98.1%, respectively. This method is highly sensitive, fast and selective, which can be used for the determination of nucleosides in C. sinensis and its substitutes. This method can also be applied for the quality control of above herbs.


  • Rapid, simple, specific liquid chromatographic-electrospray mass spectrometry method for the determination of glibenclamide in human plasma

    by Ben-Mei Chen, Yi-Zeng Liang, Fang-Qiu Guo, Lan-Fang Huang, Fu-Liang Deng, Xin Chen, Ya-Li Wang