Daniel Kacik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daniel Kacik has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Kay Schuster
Leibniz-Institut für Photonische Technologien e.V. (Germany)
4 shared publications - Dusan Pudis
Department of Physics, Faculty of Electrical Engineering and Information Technology, University of Zilina, Univerzitna 1, 01026 Zilina, Slovakia
2 shared publications - Ivan Martincek
Univ Zilina, Dept Phys, SK-01026 Zilina, Slovakia
2 shared publications Ivan Martinček
Univ. of Žilina (Slovakia)
2 shared publications- Norbert Tarjányi
Univ. of Žilina (Slovakia)
2 shared publications Ivan Martincek
Univ. of Žilina (Slovakia)
1 shared publication
Latest Publications
- 9 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10680, 106801X
Polydimethylsiloxane Fabry-Perot interferometer and its sensing application
A preparation of polydimethylsiloxane (PDMS) interferometer located at the end of a single-mode optical fiber is presented. For preparation of Fabry-Perot interferometer (FPI) we used the PDMS Sylgard 184 (Dow Corning). During fabrication process of FPI the length of micro-cavity in PDMS can be set to required size. After the setting the length of microcavity was fixed by encapsulating of another layer of PDMS. By measuring the transmission characteristic under the constant conditions of environments we observe a periodic change of signal depending on the wavelength – interference pattern. When the measurand is applied on FPI, PDMS changes its volume and also its refractive index resulting in a change in length of microcavity. The change of length of FPI modifies the interference pattern. For evaluation of influence of measurands change, we chose one maximum (wavelength of the maximum) as a reference wavelength at the reflected spectra. Then we changed the amount of measurand and we observed wavelength shift of the maximum and compared it with the wavelength of reference maximum of reflected spectra. We investigated the sensitivity of PDMS FPI on temperature and pressure. The dependencies to temperature and pressure have linear character. The temperature sensitivity of fabricated PDMS FPI is 5.76 nm/°C. In free spectral range of FPI it is possible to determine the difference of temperature 2.7 °C. After that 2π jump in reflected spectra occurs. The pressure sensitivity is -0.64 nm/kPa and free spectral range of FPI corresponds to 11 kPa.
- 9 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10680, 106801X
Polydimethylsiloxane Fabry-Perot interferometer and its sensing application
A preparation of polydimethylsiloxane (PDMS) interferometer located at the end of a single-mode optical fiber is presented. For preparation of Fabry-Perot interferometer (FPI) we used the PDMS Sylgard 184 (Dow Corning). During fabrication process of FPI the length of micro-cavity in PDMS can be set to required size. After the setting the length of microcavity was fixed by encapsulating of another layer of PDMS. By measuring the transmission characteristic under the constant conditions of environments we observe a periodic change of signal depending on the wavelength – interference pattern. When the measurand is applied on FPI, PDMS changes its volume and also its refractive index resulting in a change in length of microcavity. The change of length of FPI modifies the interference pattern. For evaluation of influence of measurands change, we chose one maximum (wavelength of the maximum) as a reference wavelength at the reflected spectra. Then we changed the amount of measurand and we observed wavelength shift of the maximum and compared it with the wavelength of reference maximum of reflected spectra. We investigated the sensitivity of PDMS FPI on temperature and pressure. The dependencies to temperature and pressure have linear character. The temperature sensitivity of fabricated PDMS FPI is 5.76 nm/°C. In free spectral range of FPI it is possible to determine the difference of temperature 2.7 °C. After that 2π jump in reflected spectra occurs. The pressure sensitivity is -0.64 nm/kPa and free spectral range of FPI corresponds to 11 kPa.
- 24 December 2016
- Published by SPIE-Intl Soc Optical Eng
- p. 101421K-101421K-6
Miniature fiber temperature sensor based on Fabry-Perot interferometer
- 24 December 2016
- Published by SPIE-Intl Soc Optical Eng
- p. 101421K-101421K-6
Miniature fiber temperature sensor based on Fabry-Perot interferometer
- 30 July 2014
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 61 (19) , 1621-1624
Refractometer based on resonance investigation of capillary cladding modes
A simple refractometer is demonstrated using a fused silica capillary spliced between two single-mode fibers. From a fundamental mode of a lead-in single-mode fiber, a number of cladding modes in the short piece of the capillary are excited. In the transmission spectrum, it could be as a formation of the resonance peaks observed. The experimental results of three different capillary diameter values are described. We presented the sensitivity comparison of all three cases for the liquid analyte refractive index (na) variations in the range from na = 1.33 to na = 1.43. The sensitivity improvement in the range from na = 1.3 to na = 1.35–195.4 nm/RIU is also presented. The proposed refractometer can be further developed as a simple and inexpensive solution for biosensor applications.
- 30 July 2014
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 61 (19) , 1621-1624
Refractometer based on resonance investigation of capillary cladding modes
A simple refractometer is demonstrated using a fused silica capillary spliced between two single-mode fibers. From a fundamental mode of a lead-in single-mode fiber, a number of cladding modes in the short piece of the capillary are excited. In the transmission spectrum, it could be as a formation of the resonance peaks observed. The experimental results of three different capillary diameter values are described. We presented the sensitivity comparison of all three cases for the liquid analyte refractive index (na) variations in the range from na = 1.33 to na = 1.43. The sensitivity improvement in the range from na = 1.3 to na = 1.35–195.4 nm/RIU is also presented. The proposed refractometer can be further developed as a simple and inexpensive solution for biosensor applications.
- Open Access
Volume Fraction Determination of Binary Liquid Mixtures by Measurement of the Equalization Wavelength
A method for determination of the volume fraction in binary liquid mixtures by measurement of the equalization wavelength of intermodal interference of modes LP01 and LP11 in a liquid core optical fiber is presented in this paper. This method was studied using a liquid core optical fiber with fused silica cladding and a core made up of a binary silicon oil/chloroform liquid mixture with different volume fractions of chloroform. The interference technique used allows us to determine the chloroform volume fraction in the binary mixture with accuracy better than 0.1%. One of the most attractive advantages of presented method is very small volume of investigated mixture needed, as only a few hundred picoliters are necessary for reliable results.
Open AccessVolume Fraction Determination of Binary Liquid Mixtures by Measurement of the Equalization Wavelength
A method for determination of the volume fraction in binary liquid mixtures by measurement of the equalization wavelength of intermodal interference of modes LP01 and LP11 in a liquid core optical fiber is presented in this paper. This method was studied using a liquid core optical fiber with fused silica cladding and a core made up of a binary silicon oil/chloroform liquid mixture with different volume fractions of chloroform. The interference technique used allows us to determine the chloroform volume fraction in the binary mixture with accuracy better than 0.1%. One of the most attractive advantages of presented method is very small volume of investigated mixture needed, as only a few hundred picoliters are necessary for reliable results.