Michele Gianella
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michele Gianella has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Dieter Hahnloser
Department of Visceral Surgery, Lausanne University Hospital (CHUV), University of Lausanne (UNIL), 1011 Lausanne, Switzerland
1 shared publication - Markus W. Sigrist
ETH Zurich
1 shared publication - Markus Werner Sigrist
ETH Zurich
1 shared publication - Martin Hübner
Department of Visceral Surgery, Lausanne University Hospital (CHUV), University of Lausanne (UNIL), 1011 Lausanne, Switzerland
1 shared publication - Nicolas Demartines
Department of Visceral Surgery, University Hospital Lausanne, Switzerland
1 shared publication - Pierre-Alain Clavien
University Hospital Zürich, Rämistrasse 100, 8091 Zürich, Switzerland
1 shared publication
Latest Publications
- Open Access
Infrared Spectroscopy on Smoke Produced by Cauterization of Animal Tissue
In view of in vivo surgical smoke studies a difference-frequency-generation (DFG) laser spectrometer (spectral range 2900–3144 cm-1) and a Fourier-transform infrared (FTIR) spectrometer were employed for infrared absorption spectroscopy. The chemical composition of smoke produced in vitro with an electroknife by cauterization of different animal tissues in different atmospheres was investigated. Average concentrations derived are: water vapor (0.87%), methane (20 ppm), ethane (4.8 ppm), ethene (17 ppm), carbon monoxide (190 ppm), nitric oxide (25 ppm), nitrous oxide (40 ppm), ethyne (50 ppm) and hydrogen cyanide (25 ppm). No correlation between smoke composition and the atmosphere or the kind of cauterized tissue was found.
Open AccessInfrared Spectroscopy on Smoke Produced by Cauterization of Animal Tissue
In view of in vivo surgical smoke studies a difference-frequency-generation (DFG) laser spectrometer (spectral range 2900–3144 cm-1) and a Fourier-transform infrared (FTIR) spectrometer were employed for infrared absorption spectroscopy. The chemical composition of smoke produced in vitro with an electroknife by cauterization of different animal tissues in different atmospheres was investigated. Average concentrations derived are: water vapor (0.87%), methane (20 ppm), ethane (4.8 ppm), ethene (17 ppm), carbon monoxide (190 ppm), nitric oxide (25 ppm), nitrous oxide (40 ppm), ethyne (50 ppm) and hydrogen cyanide (25 ppm). No correlation between smoke composition and the atmosphere or the kind of cauterized tissue was found.
- Open Access
- 19 September 2008
- Published by Springer Nature in Patient Safety in Surgery
- Vol. 2 (1) , 22
Gas emission during laparoscopic colorectal surgery using a bipolar vessel sealing device: A pilot study on four patients
Dissection during laparoscopic surgery produces smoke containing potentially toxic substances. The aim of the present study was to analyze smoke samples produced during laparoscopic colon surgery using a bipolar vessel sealing device (LigaSure™). Four consecutive patients undergoing left-sided colectomy were enrolled in this pilot study. Smoke was produced by the use of LigaSure™. Samples (5,5l) were evacuated from the pneumoperitoneum in a closed system into a reservoir. Analysis was performed with CO2-laser-based photoacoustic spectroscopy and confirmed by a Fourier-transform infrared spectrum. The detected spectra were compared to the available spectra of known toxins. Samples from four laparoscopic sigmoid resections were analyzed. No relevant differences were noted regarding patient and operation characteristics. The gas samples were stable over time proven by congruent control measurements as late as 24 h after sampling. The absorption spectra differed considerably between the patients. One broad absorption line at 100 ppm indicating H2O and several unknown molecules were detected. With a sensitivity of alpha min ca 10-5 cm-1 no known toxic substances like phenol or indole were identified. The use of a vessel sealing device during laparoscopic surgery does not produce known toxic substances in relevant quantity. Further studies are needed to identify unknown molecules and to analyze gas emission under various conditions.
- 19 September 2008
- Published by Springer Nature in Patient Safety in Surgery
- Vol. 2 (1) , 22
Open AccessGas emission during laparoscopic colorectal surgery using a bipolar vessel sealing device: A pilot study on four patients
Dissection during laparoscopic surgery produces smoke containing potentially toxic substances. The aim of the present study was to analyze smoke samples produced during laparoscopic colon surgery using a bipolar vessel sealing device (LigaSure™). Four consecutive patients undergoing left-sided colectomy were enrolled in this pilot study. Smoke was produced by the use of LigaSure™. Samples (5,5l) were evacuated from the pneumoperitoneum in a closed system into a reservoir. Analysis was performed with CO2-laser-based photoacoustic spectroscopy and confirmed by a Fourier-transform infrared spectrum. The detected spectra were compared to the available spectra of known toxins. Samples from four laparoscopic sigmoid resections were analyzed. No relevant differences were noted regarding patient and operation characteristics. The gas samples were stable over time proven by congruent control measurements as late as 24 h after sampling. The absorption spectra differed considerably between the patients. One broad absorption line at 100 ppm indicating H2O and several unknown molecules were detected. With a sensitivity of alpha min ca 10-5 cm-1 no known toxic substances like phenol or indole were identified. The use of a vessel sealing device during laparoscopic surgery does not produce known toxic substances in relevant quantity. Further studies are needed to identify unknown molecules and to analyze gas emission under various conditions.