Sang Hun Shin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sang Hun Shin has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Wook Jae Yoo
Konkuk University
12 shared publications - Bongsoo Lee
School of Biomedical Engineering, College of Biomedical & Health Science, BK21 Plus Research Institute of Biomedical Engineering, Konkuk University, 268 Chungwon-daero, Chungju-si, Chungcheongbuk-do 380-701, Korea
8 shared publications - Kyoung Won Jang
Research Center, Dongnam Institute of Radiological and Medical Sciences, Busan, Korea
8 shared publications Bongsoo Lee
Chung-Ang University
6 shared publicationsKyoung Won Jang
Konkuk University
6 shared publications- Seunghyun Cho
Department of Organic Materials & Fiber Engineering, College of Engineering, Soongsil University, 369 Sangdo-ro, Dongjak-gu, Seoul-si 156-743, Korea
6 shared publications
Latest Publications
- 19 November 2017
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 71 (11) , 842-847
Characterization of light transmissions in various optical fibers with proton beam
As a feasibility study on the development of a fiber-optic radiation sensor for proton therapy dosimetry, we characterized light transmissions of various commercial optical fibers such as silica and plastic based optical fibers by the irradiation of proton beams. In this study, we measured light transmission spectra of optical fibers as a function of absorbed doses of proton beams using a deuterium & tungsten halogen lamps and a spectrometer. To be used as a fiber-optic radiation sensor, the optical fibers should have the radiation resistant characteristics and provide stable output signals during the proton beam irradiation. In this study, we could select suitable optical fibers to be used in the fiber-optic radiation sensor without quenching effects for proton therapy dosimetry. As a result, the light transmittance of the optical fibers had decreasing trends with increasing absorbed dose as expected.
- 19 November 2017
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 71 (11) , 842-847
Characterization of light transmissions in various optical fibers with proton beam
As a feasibility study on the development of a fiber-optic radiation sensor for proton therapy dosimetry, we characterized light transmissions of various commercial optical fibers such as silica and plastic based optical fibers by the irradiation of proton beams. In this study, we measured light transmission spectra of optical fibers as a function of absorbed doses of proton beams using a deuterium & tungsten halogen lamps and a spectrometer. To be used as a fiber-optic radiation sensor, the optical fibers should have the radiation resistant characteristics and provide stable output signals during the proton beam irradiation. In this study, we could select suitable optical fibers to be used in the fiber-optic radiation sensor without quenching effects for proton therapy dosimetry. As a result, the light transmittance of the optical fibers had decreasing trends with increasing absorbed dose as expected.
- 25 July 2017
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 71 (12) , 923-927
Simultaneous measurement of alpha and beta particles using dual-type fiber-optic radiation sensor
In this study, we fabricated a dual-type fiber-optic radiation sensor (DFORS) system using a spectroscopic technique, for simultaneous and separate measurement of alpha and beta particles. The DFORS is composed of a sensing probe, plastic optical fiber (POF), photomultiplier tube (PMT)- amplifier system, and multichannel analyzer (MCA). A dual scintillator consisting of a ZnS(Ag) film and a CaF2(Eu) crystal was used for alpha and beta spectroscopy as a sensing probe. 210Po and 90Sr were used as alpha and beta emitters, respectively, and alpha and beta energy spectra were measured using the proposed DFORS system to discriminate species of the radioisotopes emitting alpha or beta particles. From the experimental results, we demonstrated that the small-sized, flexible, and insertable DFORS system could discriminate the alpha and beta events successfully using the spectral information of each radiation sources.
- 25 July 2017
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 71 (12) , 923-927
Simultaneous measurement of alpha and beta particles using dual-type fiber-optic radiation sensor
In this study, we fabricated a dual-type fiber-optic radiation sensor (DFORS) system using a spectroscopic technique, for simultaneous and separate measurement of alpha and beta particles. The DFORS is composed of a sensing probe, plastic optical fiber (POF), photomultiplier tube (PMT)- amplifier system, and multichannel analyzer (MCA). A dual scintillator consisting of a ZnS(Ag) film and a CaF2(Eu) crystal was used for alpha and beta spectroscopy as a sensing probe. 210Po and 90Sr were used as alpha and beta emitters, respectively, and alpha and beta energy spectra were measured using the proposed DFORS system to discriminate species of the radioisotopes emitting alpha or beta particles. From the experimental results, we demonstrated that the small-sized, flexible, and insertable DFORS system could discriminate the alpha and beta events successfully using the spectral information of each radiation sources.
- 18 April 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10251, 102511
Dual type fiber-optic radiation sensor for measuring alpha and beta particles
In this study, we fabricated a dual type fiber-optic radiation sensor (DFORS) system using a spectroscopic technique to measure alpha and beta particles simultaneously and separately. The DFORS is composed of a sensing probe, a plastic optical fiber (POF), a photomultiplier tube (PMT)-amplifier system, and a multichannel analyzer (MCA). As sensing probes, a ZnS(Ag) film and CaF2(Eu) crystal were used for alpha and beta spectroscopy. And, we measured the alpha and beta energy spectra using the proposed DFORS system to discriminate species of the radioisotopes emitting alpha or beta particle. From the experimental results, we demonstrated that the small-sized, flexible, and insertable DFORS system can measure and discriminate the alpha and beta successfully with the spectral information of each radioisotope. © (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 18 April 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10251, 102511
Dual type fiber-optic radiation sensor for measuring alpha and beta particles
In this study, we fabricated a dual type fiber-optic radiation sensor (DFORS) system using a spectroscopic technique to measure alpha and beta particles simultaneously and separately. The DFORS is composed of a sensing probe, a plastic optical fiber (POF), a photomultiplier tube (PMT)-amplifier system, and a multichannel analyzer (MCA). As sensing probes, a ZnS(Ag) film and CaF2(Eu) crystal were used for alpha and beta spectroscopy. And, we measured the alpha and beta energy spectra using the proposed DFORS system to discriminate species of the radioisotopes emitting alpha or beta particle. From the experimental results, we demonstrated that the small-sized, flexible, and insertable DFORS system can measure and discriminate the alpha and beta successfully with the spectral information of each radioisotope. © (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- Open Access
Feasibility of Ultra-Thin Fiber-Optic Dosimeters for Radiotherapy Dosimetry
In this study, prototype ultra-thin fiber-optic dosimeters were fabricated using organic scintillators, wavelength shifting fibers, and plastic optical fibers. The sensor probes of the ultra-thin fiber-optic dosimeters consisted of very thin organic scintillators with thicknesses of 100, 150 and 200 μm. These types of sensors cannot only be used to measure skin or surface doses but also provide depth dose measurements with high spatial resolution. With the ultra-thin fiber-optic dosimeters, surface doses for gamma rays generated from a Co-60 therapy machine were measured. Additionally, percentage depth doses in the build-up regions were obtained by using the ultra-thin fiber-optic dosimeters, and the results were compared with those of external beam therapy films and a conventional fiber-optic dosimeter.
Open AccessFeasibility of Ultra-Thin Fiber-Optic Dosimeters for Radiotherapy Dosimetry
In this study, prototype ultra-thin fiber-optic dosimeters were fabricated using organic scintillators, wavelength shifting fibers, and plastic optical fibers. The sensor probes of the ultra-thin fiber-optic dosimeters consisted of very thin organic scintillators with thicknesses of 100, 150 and 200 μm. These types of sensors cannot only be used to measure skin or surface doses but also provide depth dose measurements with high spatial resolution. With the ultra-thin fiber-optic dosimeters, surface doses for gamma rays generated from a Co-60 therapy machine were measured. Additionally, percentage depth doses in the build-up regions were obtained by using the ultra-thin fiber-optic dosimeters, and the results were compared with those of external beam therapy films and a conventional fiber-optic dosimeter.
- Open Access
Performance Evaluation of a Multichannel All-In-One Phantom Dosimeter for Dose Measurement of Diagnostic X-ray Beam
We developed a multichannel all-in-one phantom dosimeter system composed of nine sensing probes, a chest phantom, an image intensifier, and a complementary metal-oxide semiconductor (CMOS) image sensor to measure the dose distribution of an X-ray beam used in radiation diagnosis. Nine sensing probes of the phantom dosimeter were fabricated identically by connecting a plastic scintillating fiber (PSF) to a plastic optical fiber (POF). To measure the planar dose distribution on a chest phantom according to exposure parameters used in clinical practice, we divided the top of the chest phantom into nine equal parts virtually and then installed the nine sensing probes at each center of the nine equal parts on the top of the chest phantom as measuring points. Each scintillation signal generated in the nine sensing probes was transmitted through the POFs and then intensified by the image intensifier because the scintillation signal normally has a very low light intensity. Real-time scintillation images (RSIs) containing the intensified scintillation signals were taken by the CMOS image sensor with a single lens optical system and displayed through a software program. Under variation of the exposure parameters, we measured RSIs containing dose information using the multichannel all-in-one phantom dosimeter and compared the results with the absorbed doses obtained by using a semiconductor dosimeter (SCD). From the experimental results of this study, the light intensities of nine regions of interest (ROI) in the RSI measured by the phantom dosimeter were similar to the dose distribution obtained using the SCD. In conclusion, we demonstrated that the planar dose distribution including the entrance surface dose (ESD) can be easily measured by using the proposed phantom dosimeter system.
Open AccessPerformance Evaluation of a Multichannel All-In-One Phantom Dosimeter for Dose Measurement of Diagnostic X-ray Beam
We developed a multichannel all-in-one phantom dosimeter system composed of nine sensing probes, a chest phantom, an image intensifier, and a complementary metal-oxide semiconductor (CMOS) image sensor to measure the dose distribution of an X-ray beam used in radiation diagnosis. Nine sensing probes of the phantom dosimeter were fabricated identically by connecting a plastic scintillating fiber (PSF) to a plastic optical fiber (POF). To measure the planar dose distribution on a chest phantom according to exposure parameters used in clinical practice, we divided the top of the chest phantom into nine equal parts virtually and then installed the nine sensing probes at each center of the nine equal parts on the top of the chest phantom as measuring points. Each scintillation signal generated in the nine sensing probes was transmitted through the POFs and then intensified by the image intensifier because the scintillation signal normally has a very low light intensity. Real-time scintillation images (RSIs) containing the intensified scintillation signals were taken by the CMOS image sensor with a single lens optical system and displayed through a software program. Under variation of the exposure parameters, we measured RSIs containing dose information using the multichannel all-in-one phantom dosimeter and compared the results with the absorbed doses obtained by using a semiconductor dosimeter (SCD). From the experimental results of this study, the light intensities of nine regions of interest (ROI) in the RSI measured by the phantom dosimeter were similar to the dose distribution obtained using the SCD. In conclusion, we demonstrated that the planar dose distribution including the entrance surface dose (ESD) can be easily measured by using the proposed phantom dosimeter system.
- 1 November 2015
- Published by The Korean Institute of Electrical Engineers in The Transactions of The Korean Institute of Electrical Engineers
- Vol. 64 (11) , 1592-1597
Fiber-optic Temperature Sensor Using a Silicone Oil and an OTDR
- 1 November 2015
- Published by The Korean Institute of Electrical Engineers in The Transactions of The Korean Institute of Electrical Engineers
- Vol. 64 (11) , 1592-1597
Fiber-optic Temperature Sensor Using a Silicone Oil and an OTDR
- Open Access
Development of a Small-Sized, Flexible, and Insertable Fiber-Optic Radiation Sensor for Gamma-Ray Spectroscopy
We fabricated a small-sized, flexible, and insertable fiber-optic radiation sensor (FORS) that is composed of a sensing probe, a plastic optical fiber (POF), a photomultiplier tube (PMT)-amplifier system, and a multichannel analyzer (MCA) to obtain the energy spectra of radioactive isotopes. As an inorganic scintillator for gamma-ray spectroscopy, a cerium-doped lutetium yttrium orthosilicate (LYSO:Ce) crystal was used and two solid-disc type radioactive isotopes with the same dimensions, cesium-137 (Cs-137) and cobalt-60 (Co-60), were used as gamma-ray emitters. We first determined the length of the LYSO:Ce crystal considering the absorption of charged particle energy and measured the gamma-ray energy spectra using the FORS. The experimental results demonstrated that the proposed FORS can be used to discriminate species of radioactive isotopes by measuring their inherent energy spectra, even when gamma-ray emitters are mixed. The relationship between the measured photon counts of the FORS and the radioactivity of Cs-137 was subsequently obtained. The amount of scintillating light generated from the FORS increased by increasing the radioactivity of Cs-137. Finally, the performance of the fabricated FORS according to the length and diameter of the POF was also evaluated. Based on the results of this study, it is anticipated that a novel FORS can be developed to accurately measure the gamma-ray energy spectrum in inaccessible locations such as narrow areas and holes.
Open AccessDevelopment of a Small-Sized, Flexible, and Insertable Fiber-Optic Radiation Sensor for Gamma-Ray Spectroscopy
We fabricated a small-sized, flexible, and insertable fiber-optic radiation sensor (FORS) that is composed of a sensing probe, a plastic optical fiber (POF), a photomultiplier tube (PMT)-amplifier system, and a multichannel analyzer (MCA) to obtain the energy spectra of radioactive isotopes. As an inorganic scintillator for gamma-ray spectroscopy, a cerium-doped lutetium yttrium orthosilicate (LYSO:Ce) crystal was used and two solid-disc type radioactive isotopes with the same dimensions, cesium-137 (Cs-137) and cobalt-60 (Co-60), were used as gamma-ray emitters. We first determined the length of the LYSO:Ce crystal considering the absorption of charged particle energy and measured the gamma-ray energy spectra using the FORS. The experimental results demonstrated that the proposed FORS can be used to discriminate species of radioactive isotopes by measuring their inherent energy spectra, even when gamma-ray emitters are mixed. The relationship between the measured photon counts of the FORS and the radioactivity of Cs-137 was subsequently obtained. The amount of scintillating light generated from the FORS increased by increasing the radioactivity of Cs-137. Finally, the performance of the fabricated FORS according to the length and diameter of the POF was also evaluated. Based on the results of this study, it is anticipated that a novel FORS can be developed to accurately measure the gamma-ray energy spectrum in inaccessible locations such as narrow areas and holes.
- Open Access
- 31 May 2015
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 24 (3) , 202-207
Fabrication and Performance Evaluation of a Scintillating Film-based Gamma Imaging Detector to Measure Gamma-ray Distribution
- 31 May 2015
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 24 (3) , 202-207
Open AccessFabrication and Performance Evaluation of a Scintillating Film-based Gamma Imaging Detector to Measure Gamma-ray Distribution
- Open Access
Effects of Temperature and X-rays on Plastic Scintillating Fiber and Infrared Optical Fiber
In this study, we have studied the effects of temperature and X-ray energy variations on the light output signals from two different fiber-optic sensors, a fiber-optic dosimeter (FOD) based on a BCF-12 as a plastic scintillating fiber (PSF) and a fiber-optic thermometer (FOT) using a silver halide optical fiber as an infrared optical fiber (IR fiber). During X-ray beam irradiation, the scintillating light and IR signals were measured simultaneously using a dosimeter probe of the FOD and a thermometer probe of the FOT. The probes were placed in a beaker with water on the center of a hotplate, under variation of the tube potential of a digital radiography system or the temperature of the water in the beaker. From the experimental results, in the case of the PSF, the scintillator light output at the given tube potential decreased as the temperature increased in the temperature range from 25 to 60 °C. We demonstrated that commonly used BCF-12 has a significant temperature dependence of −0.263 ± 0.028%/°C in the clinical temperature range. Next, in the case of the IR fiber, the intensity of the IR signal was almost uniform at each temperature regardless of the tube potential range from 50 to 150 kVp. Therefore, we also demonstrated that the X-ray beam with an energy range used in diagnostic radiology does not affect the IR signals transmitted via a silver halide optical fiber.
Open AccessEffects of Temperature and X-rays on Plastic Scintillating Fiber and Infrared Optical Fiber
In this study, we have studied the effects of temperature and X-ray energy variations on the light output signals from two different fiber-optic sensors, a fiber-optic dosimeter (FOD) based on a BCF-12 as a plastic scintillating fiber (PSF) and a fiber-optic thermometer (FOT) using a silver halide optical fiber as an infrared optical fiber (IR fiber). During X-ray beam irradiation, the scintillating light and IR signals were measured simultaneously using a dosimeter probe of the FOD and a thermometer probe of the FOT. The probes were placed in a beaker with water on the center of a hotplate, under variation of the tube potential of a digital radiography system or the temperature of the water in the beaker. From the experimental results, in the case of the PSF, the scintillator light output at the given tube potential decreased as the temperature increased in the temperature range from 25 to 60 °C. We demonstrated that commonly used BCF-12 has a significant temperature dependence of −0.263 ± 0.028%/°C in the clinical temperature range. Next, in the case of the IR fiber, the intensity of the IR signal was almost uniform at each temperature regardless of the tube potential range from 50 to 150 kVp. Therefore, we also demonstrated that the X-ray beam with an energy range used in diagnostic radiology does not affect the IR signals transmitted via a silver halide optical fiber.
- 1 January 2015
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1083, 137-141
Comparison of Optical and Scintillation Images Obtained by Using a Fiber-Optic Beta/Gamma Imaging Detector
We developed a fiber-optic beta/gamma imaging detector that can obtain the scintillating images for beta-or gamma-ray emitted from the radioisotope. To evaluate spatial resolution of proposed imaging detector, we obtained the optical images using USAF 1951 resolution target. And then, a modulation transfer function curve of the optical image was calculated. Also, we measured the scintillating images of Tl-204 and Cs-137 with information respecting the beta-and gamma-rays distribution. Finally, the intensities of scintillating light as a function of radioactivity were analyzed from the region of interest in the scintillating image.
- 1 January 2015
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1083, 137-141
Comparison of Optical and Scintillation Images Obtained by Using a Fiber-Optic Beta/Gamma Imaging Detector
We developed a fiber-optic beta/gamma imaging detector that can obtain the scintillating images for beta-or gamma-ray emitted from the radioisotope. To evaluate spatial resolution of proposed imaging detector, we obtained the optical images using USAF 1951 resolution target. And then, a modulation transfer function curve of the optical image was calculated. Also, we measured the scintillating images of Tl-204 and Cs-137 with information respecting the beta-and gamma-rays distribution. Finally, the intensities of scintillating light as a function of radioactivity were analyzed from the region of interest in the scintillating image.