Seunghyun Cho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Seunghyun Cho has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Sang Hun Shin
Konkuk University
6 shared publications - Wook Jae Yoo
Konkuk University
5 shared publications Bongsoo Lee
4 shared publications- Bongsoo Lee
School of Biomedical Engineering, College of Biomedical & Health Science, BK21 Plus Research Institute of Biomedical Engineering, Konkuk University, 268 Chungwon-daero, Chungju-si, Chungcheongbuk-do 380-701, Korea
3 shared publications Kyoung Won Jang
3 shared publications- Kyoung Won Jang
Research Center, Dongnam Institute of Radiological and Medical Sciences, Busan, Korea
3 shared publications
Latest Publications
- Open Access
Plastic Scintillating Fiber Mesh Array Detector for Two-Dimensional Gamma-Ray Source Localization Using an Artificial Neural Network
In this study, a two-dimensional gamma-ray source localization system using a mesh array of plastic scintillating fibers and an artificial neural network is presented. The system covers a 200 cm by 100 cm area using SCSF-78 multi-cladded fibers. A novel U-shaped fiber topology connects both fiber ends to one side, requiring only two data-acquisition systems. Silicon photomultiplier arrays measure fast time-of-flight under optimized operating conditions to maximize signal yield. An independent artificial neural network model map measured time-of-flight values to spatial coordinates, compensating for systematic non idealities. Performance was validated using a Cesium-137 source at 20 random test positions. The artificial neural network method achieved a mean full-scale error of 4.6%. This demonstrated a 79.34% accuracy improvement over direct theoretical calculation, which had a mean full-scale error of 22.5%. The system showed consistent performance, achieving a two-dimensional standard deviation of 0.492 cm during repeatability assessment. This methodology provides a practical, efficient approach to two-dimensional radiation source localization suitable for real time monitoring and contamination mapping.
Open AccessPlastic Scintillating Fiber Mesh Array Detector for Two-Dimensional Gamma-Ray Source Localization Using an Artificial Neural Network
In this study, a two-dimensional gamma-ray source localization system using a mesh array of plastic scintillating fibers and an artificial neural network is presented. The system covers a 200 cm by 100 cm area using SCSF-78 multi-cladded fibers. A novel U-shaped fiber topology connects both fiber ends to one side, requiring only two data-acquisition systems. Silicon photomultiplier arrays measure fast time-of-flight under optimized operating conditions to maximize signal yield. An independent artificial neural network model map measured time-of-flight values to spatial coordinates, compensating for systematic non idealities. Performance was validated using a Cesium-137 source at 20 random test positions. The artificial neural network method achieved a mean full-scale error of 4.6%. This demonstrated a 79.34% accuracy improvement over direct theoretical calculation, which had a mean full-scale error of 22.5%. The system showed consistent performance, achieving a two-dimensional standard deviation of 0.492 cm during repeatability assessment. This methodology provides a practical, efficient approach to two-dimensional radiation source localization suitable for real time monitoring and contamination mapping.
- 1 November 2015
- Published by The Korean Institute of Electrical Engineers in The Transactions of The Korean Institute of Electrical Engineers
- Vol. 64 (11) , 1592-1597
Fiber-optic Temperature Sensor Using a Silicone Oil and an OTDR
- 1 November 2015
- Published by The Korean Institute of Electrical Engineers in The Transactions of The Korean Institute of Electrical Engineers
- Vol. 64 (11) , 1592-1597
Fiber-optic Temperature Sensor Using a Silicone Oil and an OTDR
- Open Access
Development of a Small-Sized, Flexible, and Insertable Fiber-Optic Radiation Sensor for Gamma-Ray Spectroscopy
We fabricated a small-sized, flexible, and insertable fiber-optic radiation sensor (FORS) that is composed of a sensing probe, a plastic optical fiber (POF), a photomultiplier tube (PMT)-amplifier system, and a multichannel analyzer (MCA) to obtain the energy spectra of radioactive isotopes. As an inorganic scintillator for gamma-ray spectroscopy, a cerium-doped lutetium yttrium orthosilicate (LYSO:Ce) crystal was used and two solid-disc type radioactive isotopes with the same dimensions, cesium-137 (Cs-137) and cobalt-60 (Co-60), were used as gamma-ray emitters. We first determined the length of the LYSO:Ce crystal considering the absorption of charged particle energy and measured the gamma-ray energy spectra using the FORS. The experimental results demonstrated that the proposed FORS can be used to discriminate species of radioactive isotopes by measuring their inherent energy spectra, even when gamma-ray emitters are mixed. The relationship between the measured photon counts of the FORS and the radioactivity of Cs-137 was subsequently obtained. The amount of scintillating light generated from the FORS increased by increasing the radioactivity of Cs-137. Finally, the performance of the fabricated FORS according to the length and diameter of the POF was also evaluated. Based on the results of this study, it is anticipated that a novel FORS can be developed to accurately measure the gamma-ray energy spectrum in inaccessible locations such as narrow areas and holes.
Open AccessDevelopment of a Small-Sized, Flexible, and Insertable Fiber-Optic Radiation Sensor for Gamma-Ray Spectroscopy
We fabricated a small-sized, flexible, and insertable fiber-optic radiation sensor (FORS) that is composed of a sensing probe, a plastic optical fiber (POF), a photomultiplier tube (PMT)-amplifier system, and a multichannel analyzer (MCA) to obtain the energy spectra of radioactive isotopes. As an inorganic scintillator for gamma-ray spectroscopy, a cerium-doped lutetium yttrium orthosilicate (LYSO:Ce) crystal was used and two solid-disc type radioactive isotopes with the same dimensions, cesium-137 (Cs-137) and cobalt-60 (Co-60), were used as gamma-ray emitters. We first determined the length of the LYSO:Ce crystal considering the absorption of charged particle energy and measured the gamma-ray energy spectra using the FORS. The experimental results demonstrated that the proposed FORS can be used to discriminate species of radioactive isotopes by measuring their inherent energy spectra, even when gamma-ray emitters are mixed. The relationship between the measured photon counts of the FORS and the radioactivity of Cs-137 was subsequently obtained. The amount of scintillating light generated from the FORS increased by increasing the radioactivity of Cs-137. Finally, the performance of the fabricated FORS according to the length and diameter of the POF was also evaluated. Based on the results of this study, it is anticipated that a novel FORS can be developed to accurately measure the gamma-ray energy spectrum in inaccessible locations such as narrow areas and holes.
- Open Access
- 31 May 2015
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 24 (3) , 202-207
Fabrication and Performance Evaluation of a Scintillating Film-based Gamma Imaging Detector to Measure Gamma-ray Distribution
- 31 May 2015
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 24 (3) , 202-207
Open AccessFabrication and Performance Evaluation of a Scintillating Film-based Gamma Imaging Detector to Measure Gamma-ray Distribution
- Open Access
A Fiber-Optic Sensor Using an Aqueous Solution of Sodium Chloride to Measure Temperature and Water Level Simultaneously
A fiber-optic sensor system using a multiplexed array of sensing probes based on an aqueous solution of sodium chloride (NaCl solution) and an optical time-domain reflectometer (OTDR) for simultaneous measurement of temperature and water level is proposed. By changing the temperature, the refractive index of the NaCl solution is varied and Fresnel reflection arising at the interface between the distal end of optical fiber and the NaCl solution is then also changed. We measured the modified optical power of the light reflected from the sensing probe using a portable OTDR device and also obtained the relationship between the temperature of water and the optical power. In this study, the water level was simply determined by measuring the signal difference of the optical power due to the temperature difference of individual sensing probes placed inside and outside of the water. In conclusion, we demonstrate that the temperature and water level can be obtained simultaneously by measuring optical powers of light reflected from sensing probes based on the NaCl solution. It is anticipated that the proposed fiber-optic sensor system makes it possible to remotely monitor the real-time change of temperature and water level of the spent fuel pool during a loss of power accident.
Open AccessA Fiber-Optic Sensor Using an Aqueous Solution of Sodium Chloride to Measure Temperature and Water Level Simultaneously
A fiber-optic sensor system using a multiplexed array of sensing probes based on an aqueous solution of sodium chloride (NaCl solution) and an optical time-domain reflectometer (OTDR) for simultaneous measurement of temperature and water level is proposed. By changing the temperature, the refractive index of the NaCl solution is varied and Fresnel reflection arising at the interface between the distal end of optical fiber and the NaCl solution is then also changed. We measured the modified optical power of the light reflected from the sensing probe using a portable OTDR device and also obtained the relationship between the temperature of water and the optical power. In this study, the water level was simply determined by measuring the signal difference of the optical power due to the temperature difference of individual sensing probes placed inside and outside of the water. In conclusion, we demonstrate that the temperature and water level can be obtained simultaneously by measuring optical powers of light reflected from sensing probes based on the NaCl solution. It is anticipated that the proposed fiber-optic sensor system makes it possible to remotely monitor the real-time change of temperature and water level of the spent fuel pool during a loss of power accident.
- 1 September 2014
- Published by The Korean Institute of Electrical Engineers in The Transactions of The Korean Institute of Electrical Engineers
- Vol. 63 (9) , 1239-1244
Real-time Measurements of Water Level and Temperature using Fiber-optic Sensors Based on an OTDR
- 1 September 2014
- Published by The Korean Institute of Electrical Engineers in The Transactions of The Korean Institute of Electrical Engineers
- Vol. 63 (9) , 1239-1244
Real-time Measurements of Water Level and Temperature using Fiber-optic Sensors Based on an OTDR
- Open Access
Measurement of Entrance Surface Dose on an Anthropomorphic Thorax Phantom Using a Miniature Fiber-Optic Dosimeter
A miniature fiber-optic dosimeter (FOD) system was fabricated using a plastic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure real-time entrance surface dose (ESD) during radiation diagnosis. Under varying exposure parameters of a digital radiography (DR) system, we measured the scintillating light related to the ESD using the sensing probe of the FOD, which was placed at the center of the beam field on an anthropomorphic thorax phantom. Also, we obtained DR images using a flat panel detector of the DR system to evaluate the effects of the dosimeter on image artifacts during posteroanterior (PA) chest radiography. From the experimental results, the scintillation output signals of the FOD were similar to the ESDs including backscatter simultaneously obtained using a semiconductor dosimeter. We demonstrated that the proposed miniature FOD can be used to measure real-time ESDs with minimization of DR image artifacts in the X-ray energy range of diagnostic radiology.
Open AccessMeasurement of Entrance Surface Dose on an Anthropomorphic Thorax Phantom Using a Miniature Fiber-Optic Dosimeter
A miniature fiber-optic dosimeter (FOD) system was fabricated using a plastic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure real-time entrance surface dose (ESD) during radiation diagnosis. Under varying exposure parameters of a digital radiography (DR) system, we measured the scintillating light related to the ESD using the sensing probe of the FOD, which was placed at the center of the beam field on an anthropomorphic thorax phantom. Also, we obtained DR images using a flat panel detector of the DR system to evaluate the effects of the dosimeter on image artifacts during posteroanterior (PA) chest radiography. From the experimental results, the scintillation output signals of the FOD were similar to the ESDs including backscatter simultaneously obtained using a semiconductor dosimeter. We demonstrated that the proposed miniature FOD can be used to measure real-time ESDs with minimization of DR image artifacts in the X-ray energy range of diagnostic radiology.
- 31 July 2011
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 20 (4) , 266-271
Development of Reflection-type Fiber-optic pH Sensor Using Sol-gel Film
- 31 July 2011
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 20 (4) , 266-271
Development of Reflection-type Fiber-optic pH Sensor Using Sol-gel Film