Nils Paust
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nils Paust has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Lisa Drechsel
HSG-IMIT - Institut für Mikro- und Informationstechnik, Georges-Koehler-Allee 103, 79110 Freiburg, Germany.
2 shared publications - A. Kloke
HSG-IMIT - Institut für Mikro- und Informationstechnik, Georges-Köhler-Allee 103, 79110 Freiburg, Germany.
1 shared publication - A. R. Fiebach
HSG-IMIT - Institut für Mikro- und Informationstechnik
1 shared publication - Andreas Ernst
Department of Microsystems Engineering, University of Freiburg, IMTEK, Georges-Köhler Allee 103, 79110 Freiburg, Germany
1 shared publication - Arne Fallisch
Fraunhofer Institute for Solar Energy Systems ISE, Division Energy Technologies, Heidenhofstr. 2, 79110 Freiburg, Germany
1 shared publication Carmen Moldovan
National Institute for R&D in Microtechnologies, Bucharest, Romania
1 shared publication
Latest Publications
- 11 November 2014
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (3) , 704-710
Electrochemical pesticide detection with AutoDip – a portable platform for automation of crude sample analyses
Lab-on-a-chip devices hold promise for automation of complex workflows from sample to answer with minimal consumption of reagents in portable devices. However, complex, inhomogeneous samples as they occur in environmental or food analysis may block microchannels and thus often cause malfunction of the system. Here we present the novel AutoDip platform which is based on the movement of a solid phase through the reagents and sample instead of transporting a sequence of reagents through a fixed solid phase. A ball-pen mechanism operated by an external actuator automates unit operations such as incubation and washing by consecutively dipping the solid phase into the corresponding liquids. The platform is applied to electrochemical detection of organophosphorus pesticides in real food samples using an acetylcholinesterase (AChE) biosensor. Minimal sample preparation and an integrated reagent pre-storage module hold promise for easy handling of the assay. Detection of the pesticide chlorpyrifos-oxon (CPO) spiked into apple samples at concentrations of 10−7 M has been demonstrated. This concentration is below the maximum residue level for chlorpyrifos in apples defined by the European Commission.
- 11 November 2014
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (3) , 704-710
Electrochemical pesticide detection with AutoDip – a portable platform for automation of crude sample analyses
Lab-on-a-chip devices hold promise for automation of complex workflows from sample to answer with minimal consumption of reagents in portable devices. However, complex, inhomogeneous samples as they occur in environmental or food analysis may block microchannels and thus often cause malfunction of the system. Here we present the novel AutoDip platform which is based on the movement of a solid phase through the reagents and sample instead of transporting a sequence of reagents through a fixed solid phase. A ball-pen mechanism operated by an external actuator automates unit operations such as incubation and washing by consecutively dipping the solid phase into the corresponding liquids. The platform is applied to electrochemical detection of organophosphorus pesticides in real food samples using an acetylcholinesterase (AChE) biosensor. Minimal sample preparation and an integrated reagent pre-storage module hold promise for easy handling of the assay. Detection of the pesticide chlorpyrifos-oxon (CPO) spiked into apple samples at concentrations of 10−7 M has been demonstrated. This concentration is below the maximum residue level for chlorpyrifos in apples defined by the European Commission.
- Open Access
- 31 October 2014
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 4 (102) , 58888-58894
Tomography based screening of flow field / current collector combinations for PEM water electrolysis
Current collectors in PEM water electrolysis perform several functions that influence overall performance. These include conducting heat and electrons, as well as transporting water and gas. X-ray tomography, standardized reconstruction, and calculation methods are used to compare the morphological and transport parameters of eight different current collectors functioning as flow fields for PEM water electrolysis. We find simple exponential relations between through-plane thermal conductivity λ and porosity p (λ20°C(p) = 1749p−1.306 − 4.420), as well as between through-plane electrical conductivity σ and water permeability K (σ(K) = 10−6 × K−0.6376). In addition, we use both local and global concepts to investigate the pore space of current collectors. We hereby investigate homogeneity and characteristic sizes, like mean pore diameter or mean distance between solid parts at the catalytic interface. Moreover, we find that the local concept of mean chord lengths can be used to explain electrical and thermal conductivity anisotropies. These chords can be used to predict the direction of the largest conductivity for fibrous current collectors.
- 31 October 2014
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 4 (102) , 58888-58894
Open AccessTomography based screening of flow field / current collector combinations for PEM water electrolysis
Current collectors in PEM water electrolysis perform several functions that influence overall performance. These include conducting heat and electrons, as well as transporting water and gas. X-ray tomography, standardized reconstruction, and calculation methods are used to compare the morphological and transport parameters of eight different current collectors functioning as flow fields for PEM water electrolysis. We find simple exponential relations between through-plane thermal conductivity λ and porosity p (λ20°C(p) = 1749p−1.306 − 4.420), as well as between through-plane electrical conductivity σ and water permeability K (σ(K) = 10−6 × K−0.6376). In addition, we use both local and global concepts to investigate the pore space of current collectors. We hereby investigate homogeneity and characteristic sizes, like mean pore diameter or mean distance between solid parts at the catalytic interface. Moreover, we find that the local concept of mean chord lengths can be used to explain electrical and thermal conductivity anisotropies. These chords can be used to predict the direction of the largest conductivity for fibrous current collectors.
- 3 February 2014
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 14 (9) , 1527-1537
The LabTube – a novel microfluidic platform for assay automation in laboratory centrifuges
Based on a centrifugally-controlled ballpen-mechanism, the LabTube enables cost-efficient assay automation at even low sample throughput using standard centrifuges.
- 3 February 2014
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 14 (9) , 1527-1537
The LabTube – a novel microfluidic platform for assay automation in laboratory centrifuges
Based on a centrifugally-controlled ballpen-mechanism, the LabTube enables cost-efficient assay automation at even low sample throughput using standard centrifuges.
- Open Access
Numerical Investigations on Electric Field Characteristics with Respect to Capacitive Detection of Free-Flying Droplets
In this paper a multi-disciplinary simulation of a capacitive droplet sensor based on an open plate capacitor as transducing element is presented. The numerical simulations are based on the finite volume method (FVM), including calculations of an electric field which changes according to the presence of a liquid droplet. The volume of fluid (VOF) method is applied for the simulation of the ejection process of a liquid droplet out of a dispenser nozzle. The simulations were realised using the computational fluid dynamic (CFD) software CFD ACE+. The investigated capacitive sensing principle enables to determine the volume of a micro droplet passing the sensor capacitor due to the induced change in capacity. It could be found that single droplets in the considered volume range of 5 nL < Vdrop < 100 nL lead to a linear change of the capacity up to ΔQ < 30 fC. The sensitivity of the focused capacitor geometry was evaluated to be Si = 0.3 fC/nL. The simulation results are validated by experiments which exhibit good agreement.
Open AccessNumerical Investigations on Electric Field Characteristics with Respect to Capacitive Detection of Free-Flying Droplets
In this paper a multi-disciplinary simulation of a capacitive droplet sensor based on an open plate capacitor as transducing element is presented. The numerical simulations are based on the finite volume method (FVM), including calculations of an electric field which changes according to the presence of a liquid droplet. The volume of fluid (VOF) method is applied for the simulation of the ejection process of a liquid droplet out of a dispenser nozzle. The simulations were realised using the computational fluid dynamic (CFD) software CFD ACE+. The investigated capacitive sensing principle enables to determine the volume of a micro droplet passing the sensor capacitor due to the induced change in capacity. It could be found that single droplets in the considered volume range of 5 nL < Vdrop < 100 nL lead to a linear change of the capacity up to ΔQ < 30 fC. The sensitivity of the focused capacitor geometry was evaluated to be Si = 0.3 fC/nL. The simulation results are validated by experiments which exhibit good agreement.