Peter Tomčík
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Peter Tomčík has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Eva Culková
Electroanalytical Chemistry Laboratory, Department of Chemistry and Physics, Faculty of Education, Catholic University in Ružomberok, Hrabovská cesta 1, SK-034 01 Ružomberok, Slovakia
3 shared publications - Miroslav Rievaj
Electroanalytical Chemistry Laboratory, Department of Chemistry and Physics, Faculty of Education, Catholic University in Ružomberok, Hrabovská cesta 1, SK-034 01 Ružomberok, Slovakia
3 shared publications - Renata Bellová
Electroanalytical Chemistry Laboratory, Department of Chemistry and Physics, Faculty of Education, Catholic University in Ružomberok, Hrabovská cesta 1, SK-034 01 Ružomberok, Slovakia
3 shared publications - Jaroslav Durdiak
Electroanalytical Chemistry Laboratory, Department of Chemistry and Physics, Faculty of Education, Catholic University in Ružomberok, Hrabovská cesta 1, SK-034 01 Ružomberok, Slovakia
2 shared publications - Damiána Šandorová
Electroanalytical Chemistry Laboratory, Department of Chemistry and Physics, Faculty of Education, Catholic University in Ružomberok, Hrabovská cesta 1, SK-034 01 Ružomberok, Slovakia
1 shared publication - Damiána Šandorová
Electroanalytical Chemistry Laboratory, Department of Chemistry and Physics, Faculty of Education, Catholic University in Ružomberok, Hrabovská cesta 1, SK-034 01 Ružomberok, Slovakia
1 shared publication
Latest Publications
- Open Access
- 17 August 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (16) , 12875
An Interference-Free Voltammetric Method for the Detection of Sulfur Dioxide in Wine Based on a Boron-Doped Diamond Electrode and Reaction Electrochemistry
This paper describes a new, simple, and highly selective analytical technique for the detection of sulfur dioxide in wine, as a real sample with a relatively complicated matrix. The detection of the above analyte was based on the electrogeneration of iodine from iodide on a boron-doped diamond electrode, without modifications, in the presence of 0.1 mol dm−3 HClO4 as a supporting electrolyte. The electrogenerated iodine reacted with sulfur dioxide, forming iodide ions and sulfuric acid (i.e., a Bunsen reaction). The product of this reaction, the iodide ion, diffused back to the surface of the boron-doped diamond electrode and oxidized itself again. This chemical redox cycling enhanced the voltammetric response of the boron-doped diamond electrode. The selectivity of the determination was assured using NaOH and formaldehyde during sample preparation, and a blank was also measured and taken into account. The detection limit was estimated to be 10−6–10−7 mol dm−3. However, the content of sulfur dioxide in wine is significantly higher, which can lead to more accurate and reliable results.
- 17 August 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (16) , 12875
Open AccessAn Interference-Free Voltammetric Method for the Detection of Sulfur Dioxide in Wine Based on a Boron-Doped Diamond Electrode and Reaction Electrochemistry
This paper describes a new, simple, and highly selective analytical technique for the detection of sulfur dioxide in wine, as a real sample with a relatively complicated matrix. The detection of the above analyte was based on the electrogeneration of iodine from iodide on a boron-doped diamond electrode, without modifications, in the presence of 0.1 mol dm−3 HClO4 as a supporting electrolyte. The electrogenerated iodine reacted with sulfur dioxide, forming iodide ions and sulfuric acid (i.e., a Bunsen reaction). The product of this reaction, the iodide ion, diffused back to the surface of the boron-doped diamond electrode and oxidized itself again. This chemical redox cycling enhanced the voltammetric response of the boron-doped diamond electrode. The selectivity of the determination was assured using NaOH and formaldehyde during sample preparation, and a blank was also measured and taken into account. The detection limit was estimated to be 10−6–10−7 mol dm−3. However, the content of sulfur dioxide in wine is significantly higher, which can lead to more accurate and reliable results.
- Open Access
- 3 April 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (7) , 1262
A Review of Analytical Techniques for the Determination and Separation of Silver Ions and Its Nanoparticles
Many articles have already been published dealing with silver ions and its nanoparticles, but mostly from the environmental and toxicological point of view. This article is a review focused on the various analytical techniques and detection platforms used in the separation and determination of mentioned above species, especially on the trace concentration level. Commonly used are optical methods because of their high sensitivity and easy automation. The separation methods are mainly used for the separation and preconcentration of silver particles. Their combination with other analytical techniques, mainly inductively coupled plasma mass spectrometry (ICP-MS) leads to very low detection limits of analysis. The electrochemical methods are also powerful and perspective mainly because of the fabrication of new sensors designed for silver determination. All methods may be combined with each other to achieve a synergistic improvement of analytical parameters with an impact on sensitivity, selectivity and reliability. The paper comprises a review of all three types of analytical methods on the determination of trace quantities of silver ions and its nanoparticles.
- 3 April 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (7) , 1262
Open AccessA Review of Analytical Techniques for the Determination and Separation of Silver Ions and Its Nanoparticles
Many articles have already been published dealing with silver ions and its nanoparticles, but mostly from the environmental and toxicological point of view. This article is a review focused on the various analytical techniques and detection platforms used in the separation and determination of mentioned above species, especially on the trace concentration level. Commonly used are optical methods because of their high sensitivity and easy automation. The separation methods are mainly used for the separation and preconcentration of silver particles. Their combination with other analytical techniques, mainly inductively coupled plasma mass spectrometry (ICP-MS) leads to very low detection limits of analysis. The electrochemical methods are also powerful and perspective mainly because of the fabrication of new sensors designed for silver determination. All methods may be combined with each other to achieve a synergistic improvement of analytical parameters with an impact on sensitivity, selectivity and reliability. The paper comprises a review of all three types of analytical methods on the determination of trace quantities of silver ions and its nanoparticles.
- Open Access
Electroanalytical Techniques for the Detection of Selenium as a Biologically and Environmentally Significant Analyte—A Short Review
This short review deals with the properties and significance of the determination of selenium, which is in trace amounts an essential element for animals and humans, but toxic at high concentrations. It may cause oxidative stress in cells, which leads to the chronic disease called selenosis. Several analytical techniques have been developed for its detection, but electroanalytical methods are advantageous due to simple sample preparation, speed of analysis and high sensitivity of measurements, especially in the case of stripping voltammetry very low detection limits even in picomoles per liter can be reached. A variety of working electrodes based on mercury, carbon, silver, platinum and gold materials were applied to the analysis of selenium in various samples. Only selenium in oxidation state + IV is electroactive therefore the most of voltammetric determinations are devoted to it. However, it is possible to detect also other forms of selenium by indirect electrochemistry approach.
Open AccessElectroanalytical Techniques for the Detection of Selenium as a Biologically and Environmentally Significant Analyte—A Short Review
This short review deals with the properties and significance of the determination of selenium, which is in trace amounts an essential element for animals and humans, but toxic at high concentrations. It may cause oxidative stress in cells, which leads to the chronic disease called selenosis. Several analytical techniques have been developed for its detection, but electroanalytical methods are advantageous due to simple sample preparation, speed of analysis and high sensitivity of measurements, especially in the case of stripping voltammetry very low detection limits even in picomoles per liter can be reached. A variety of working electrodes based on mercury, carbon, silver, platinum and gold materials were applied to the analysis of selenium in various samples. Only selenium in oxidation state + IV is electroactive therefore the most of voltammetric determinations are devoted to it. However, it is possible to detect also other forms of selenium by indirect electrochemistry approach.
- 7 January 2014
- Published by Wiley in International Journal of Chemical Kinetics
- Vol. 46 (3) , 189-196
A Method for Esterification Reaction Rate Prediction of Aliphatic Monocarboxylic Acids with Primary Alcohols in 1,4‐Dioxane Based on Two Parametrical Taft Equation
Esterification reaction rates of aliphatic monocarboxylic acids with primary alcohols in 1,4‐dioxane as inert solvent were investigated. Acids were esterified with 1‐propanol and alcohols with acetic acid as model reactants at a constant temperature of 60°C, at a fixed ionic strength and pH in a batch reactor with a constant volume. For evaluation of reaction rates, an exact kinetic equation for the equilibrium reaction was applied. Under these conditions and for low reactants, concentrations reaction rate depends only on the structure of reactants and, therefore, can be predicted by a correlation equation with two Taft coefficients (inductive and steric effects). From these equations, it is possible to estimate the esterification reaction rate constant for other acid‐alcohol pairs. This methodology may also be suitable for other kinetic systems measured under comparable experimental conditions.
- 7 January 2014
- Published by Wiley in International Journal of Chemical Kinetics
- Vol. 46 (3) , 189-196
A Method for Esterification Reaction Rate Prediction of Aliphatic Monocarboxylic Acids with Primary Alcohols in 1,4‐Dioxane Based on Two Parametrical Taft Equation
Esterification reaction rates of aliphatic monocarboxylic acids with primary alcohols in 1,4‐dioxane as inert solvent were investigated. Acids were esterified with 1‐propanol and alcohols with acetic acid as model reactants at a constant temperature of 60°C, at a fixed ionic strength and pH in a batch reactor with a constant volume. For evaluation of reaction rates, an exact kinetic equation for the equilibrium reaction was applied. Under these conditions and for low reactants, concentrations reaction rate depends only on the structure of reactants and, therefore, can be predicted by a correlation equation with two Taft coefficients (inductive and steric effects). From these equations, it is possible to estimate the esterification reaction rate constant for other acid‐alcohol pairs. This methodology may also be suitable for other kinetic systems measured under comparable experimental conditions.
- Open Access
Microelectrode Arrays with Overlapped Diffusion Layers as Electroanalytical Detectors: Theory and Basic Applications
This contribution contains a survey of basic literature dealing with arrays of microelectrodes with overlapping diffusion layers as prospective tools in contemporary electrochemistry. Photolithographic thin layer technology allows the fabrication of sensors of micrometric dimensions separated with a very small gap. This fact allows the diffusion layers of single microelectrodes to overlap as members of the array. Various basic types of microelectrode arrays with interacting diffusion layers are described and their analytical abilities are accented. Theoretical approaches to diffusion layer overlapping and the consequences of close constitution effects such as collection efficiency and redox cycling are discussed. Examples of basis applications in electroanalytical chemistry such as amperometric detectors in HPLC and substitutional stripping voltammetry are also given.
Open AccessMicroelectrode Arrays with Overlapped Diffusion Layers as Electroanalytical Detectors: Theory and Basic Applications
This contribution contains a survey of basic literature dealing with arrays of microelectrodes with overlapping diffusion layers as prospective tools in contemporary electrochemistry. Photolithographic thin layer technology allows the fabrication of sensors of micrometric dimensions separated with a very small gap. This fact allows the diffusion layers of single microelectrodes to overlap as members of the array. Various basic types of microelectrode arrays with interacting diffusion layers are described and their analytical abilities are accented. Theoretical approaches to diffusion layer overlapping and the consequences of close constitution effects such as collection efficiency and redox cycling are discussed. Examples of basis applications in electroanalytical chemistry such as amperometric detectors in HPLC and substitutional stripping voltammetry are also given.