Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Miroslav Rievaj has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Eva Culková

    Electroanalytical Chemistry Laboratory, Department of Chemistry and Physics, Faculty of Education, Catholic University in Ružomberok, Hrabovská cesta 1, SK-034 01 Ružomberok, Slovakia

    3 shared publications
  • Peter Tomčík

    Electroanalytical Chemistry Laboratory, Department of Chemistry and Physics, Faculty of Education, Catholic University in Ružomberok, Hrabovská cesta 1, SK-034 01 Ružomberok, Slovakia

    3 shared publications
  • Renata Bellová

    Electroanalytical Chemistry Laboratory, Department of Chemistry and Physics, Faculty of Education, Catholic University in Ružomberok, Hrabovská cesta 1, SK-034 01 Ružomberok, Slovakia

    3 shared publications
  • Jaroslav Durdiak

    Electroanalytical Chemistry Laboratory, Department of Chemistry and Physics, Faculty of Education, Catholic University in Ružomberok, Hrabovská cesta 1, SK-034 01 Ružomberok, Slovakia

    2 shared publications
  • Damiána Šandorová

    Electroanalytical Chemistry Laboratory, Department of Chemistry and Physics, Faculty of Education, Catholic University in Ružomberok, Hrabovská cesta 1, SK-034 01 Ružomberok, Slovakia

    1 shared publication
  • Damiána Šandorová

    Electroanalytical Chemistry Laboratory, Department of Chemistry and Physics, Faculty of Education, Catholic University in Ružomberok, Hrabovská cesta 1, SK-034 01 Ružomberok, Slovakia

    1 shared publication

Latest Publications

  • Open Access

    An Interference-Free Voltammetric Method for the Detection of Sulfur Dioxide in Wine Based on a Boron-Doped Diamond Electrode and Reaction Electrochemistry

    by Eva Culková, Zuzana Lukáčová-Chomisteková, Renata Bellová, Miroslav Rievaj, Jarmila Švancarová-Laštincová, Peter Tomčík

    This paper describes a new, simple, and highly selective analytical technique for the detection of sulfur dioxide in wine, as a real sample with a relatively complicated matrix. The detection of the above analyte was based on the electrogeneration of iodine from iodide on a boron-doped diamond electrode, without modifications, in the presence of 0.1 mol dm−3 HClO4 as a supporting electrolyte. The electrogenerated iodine reacted with sulfur dioxide, forming iodide ions and sulfuric acid (i.e., a Bunsen reaction). The product of this reaction, the iodide ion, diffused back to the surface of the boron-doped diamond electrode and oxidized itself again. This chemical redox cycling enhanced the voltammetric response of the boron-doped diamond electrode. The selectivity of the determination was assured using NaOH and formaldehyde during sample preparation, and a blank was also measured and taken into account. The detection limit was estimated to be 10−6–10−7 mol dm−3. However, the content of sulfur dioxide in wine is significantly higher, which can lead to more accurate and reliable results.


  • Open Access

    A Review of Analytical Techniques for the Determination and Separation of Silver Ions and Its Nanoparticles

    by Miroslav Rievaj, Eva Culková, Damiána Šandorová, Jaroslav Durdiak, Renáta Bellová, Peter Tomčík

    Many articles have already been published dealing with silver ions and its nanoparticles, but mostly from the environmental and toxicological point of view. This article is a review focused on the various analytical techniques and detection platforms used in the separation and determination of mentioned above species, especially on the trace concentration level. Commonly used are optical methods because of their high sensitivity and easy automation. The separation methods are mainly used for the separation and preconcentration of silver particles. Their combination with other analytical techniques, mainly inductively coupled plasma mass spectrometry (ICP-MS) leads to very low detection limits of analysis. The electrochemical methods are also powerful and perspective mainly because of the fabrication of new sensors designed for silver determination. All methods may be combined with each other to achieve a synergistic improvement of analytical parameters with an impact on sensitivity, selectivity and reliability. The paper comprises a review of all three types of analytical methods on the determination of trace quantities of silver ions and its nanoparticles.


  • Open Access

    Electroanalytical Techniques for the Detection of Selenium as a Biologically and Environmentally Significant Analyte—A Short Review

    by Miroslav Rievaj, Eva Culková, Damiána Šandorová, Zuzana Lukáčová-Chomisteková, Renata Bellová, Jaroslav Durdiak, Peter Tomčík

    This short review deals with the properties and significance of the determination of selenium, which is in trace amounts an essential element for animals and humans, but toxic at high concentrations. It may cause oxidative stress in cells, which leads to the chronic disease called selenosis. Several analytical techniques have been developed for its detection, but electroanalytical methods are advantageous due to simple sample preparation, speed of analysis and high sensitivity of measurements, especially in the case of stripping voltammetry very low detection limits even in picomoles per liter can be reached. A variety of working electrodes based on mercury, carbon, silver, platinum and gold materials were applied to the analysis of selenium in various samples. Only selenium in oxidation state + IV is electroactive therefore the most of voltammetric determinations are devoted to it. However, it is possible to detect also other forms of selenium by indirect electrochemistry approach.