Assawapong Sappat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Assawapong Sappat has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Adisorn Tuantranont
National Electronics and Computer Technology Center (NECTEC)
1 shared publication - Adisorn Tuantranont
Nanoelectronics and MEMS Laboratory, National Electronics and Computer Technology Centre, Pathum Thani, 12120, Thailand
1 shared publication Anurat Wisitsoraat
1 shared publication- Chanpen Karuwan
Center of Advanced Materials of Printed Electronics and Sensors, Materials Science Research Center, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand
1 shared publication Kata Jaruwongrungsee
1 shared publication- Tanom Lomas
Nanoelectronics and MEMS laboratory, National Electronics and Computer Technology Center (NECTEC), 112 Paholyothin Rd., Klong 1, Klong Luang, Pathumthani, Thailand
1 shared publication
Latest Publications
- 1 August 2010
- Published by American Scientific Publishers in Sensor Letters
- Vol. 8 (4) , 645-650
Vertically Aligned Carbon Nanotube Based Electrochemcial Sensor for Salbutamol Detection
- 1 August 2010
- Published by American Scientific Publishers in Sensor Letters
- Vol. 8 (4) , 645-650
Vertically Aligned Carbon Nanotube Based Electrochemcial Sensor for Salbutamol Detection
- Open Access
On-Chip Immunoassay for Determination of Urinary Albumin
An immunoassay performed on a portable microfluidic device was evaluated for the determination of urinary albumin. An increase in absorbance at 500 nm resulting from immunoagglutination was monitored directly on the poly(dimethylsiloxane) (PDMS) microchip using a portable miniature fibre-optic spectrometer. A calibration curve was linear up to 10 mg L–1 (r2 = 0.993), with a detection limit of 0.81 mg L–1 (S/N = 3). The proposed system showed good precision, with relative standard deviations (RSDs) of 5.1%, when evaluated with 10 mg L–1 albumin (n = 10). Determination of urinary albumin with the proposed system gave results highly similar to those determined by the conventional spectrophotometric method using immunoturbidimetric detection (r2 = 0.995; n = 15).
Open AccessOn-Chip Immunoassay for Determination of Urinary Albumin
An immunoassay performed on a portable microfluidic device was evaluated for the determination of urinary albumin. An increase in absorbance at 500 nm resulting from immunoagglutination was monitored directly on the poly(dimethylsiloxane) (PDMS) microchip using a portable miniature fibre-optic spectrometer. A calibration curve was linear up to 10 mg L–1 (r2 = 0.993), with a detection limit of 0.81 mg L–1 (S/N = 3). The proposed system showed good precision, with relative standard deviations (RSDs) of 5.1%, when evaluated with 10 mg L–1 albumin (n = 10). Determination of urinary albumin with the proposed system gave results highly similar to those determined by the conventional spectrophotometric method using immunoturbidimetric detection (r2 = 0.995; n = 15).