Tyler S. Ralston
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tyler S. Ralston has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Daniel L. Marks
Univ. of Illinois at Urbana-Champaign (United States)
3 shared publications - Stephen A. Boppart
University of Illinois Urbana-Champaign
3 shared publications - P. Scott Carney
Department Electrical and Computer Engineering and The Beckman Institute for Advanced Science and Technology, University of Illinois, Urbana, Illinois 61801, USA
2 shared publications - Brynmor J. Davis
The Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
1 shared publication Paul Scott. Carney
1 shared publication
Latest Publications
- Open Access
Interferometric Synthetic Aperture Microscopy: Computed Imaging for Scanned Coherent Microscopy
Three-dimensional image formation in microscopy is greatly enhanced by the use of computed imaging techniques. In particular, Interferometric Synthetic Aperture Microscopy (ISAM) allows the removal of out-of-focus blur in broadband, coherent microscopy. Earlier methods, such as optical coherence tomography (OCT), utilize interferometric ranging, but do not apply computed imaging methods and therefore must scan the focal depth to acquire extended volumetric images. ISAM removes the need to scan the focus by allowing volumetric image reconstruction from data collected at a single focal depth. ISAM signal processing techniques are similar to the Fourier migration methods of seismology and the Fourier reconstruction methods of Synthetic Aperture Radar (SAR). In this article ISAM is described and the close ties between ISAM and SAR are explored. ISAM and a simple strip-map SAR system are placed in a common mathematical framework and compared to OCT and radar respectively. This article is intended to serve as a review of ISAM, and will be especially useful to readers with a background in SAR.
Open AccessInterferometric Synthetic Aperture Microscopy: Computed Imaging for Scanned Coherent Microscopy
Three-dimensional image formation in microscopy is greatly enhanced by the use of computed imaging techniques. In particular, Interferometric Synthetic Aperture Microscopy (ISAM) allows the removal of out-of-focus blur in broadband, coherent microscopy. Earlier methods, such as optical coherence tomography (OCT), utilize interferometric ranging, but do not apply computed imaging methods and therefore must scan the focal depth to acquire extended volumetric images. ISAM removes the need to scan the focus by allowing volumetric image reconstruction from data collected at a single focal depth. ISAM signal processing techniques are similar to the Fourier migration methods of seismology and the Fourier reconstruction methods of Synthetic Aperture Radar (SAR). In this article ISAM is described and the close ties between ISAM and SAR are explored. ISAM and a simple strip-map SAR system are placed in a common mathematical framework and compared to OCT and radar respectively. This article is intended to serve as a review of ISAM, and will be especially useful to readers with a background in SAR.
- 1 December 2006
- Published by Optica Publishing Group in Optics and Photonics News
- Vol. 17 (12) , 25
Interferometric Synthetic Aperture Microscopy: Inverse Scattering for Optical Coherence Tomography
© 2006 Optical Society of America
- 1 December 2006
- Published by Optica Publishing Group in Optics and Photonics News
- Vol. 17 (12) , 25
Interferometric Synthetic Aperture Microscopy: Inverse Scattering for Optical Coherence Tomography
© 2006 Optical Society of America
- 1 January 2006
- Published by Optica Publishing Group
Non-Paraxial Solution to Inverse Scattering in Optical Coherence Tomography
The analytic solution for inverse scattering in optical coherence tomography is formulated for fields that are non-paraxial. Such a solution is important in high numerical-aperture experiments where the paraxial approximation may not be valid.
- 1 January 2006
- Published by Optica Publishing Group
Non-Paraxial Solution to Inverse Scattering in Optical Coherence Tomography
The analytic solution for inverse scattering in optical coherence tomography is formulated for fields that are non-paraxial. Such a solution is important in high numerical-aperture experiments where the paraxial approximation may not be valid.