Shafaat Ahmed Bazaz
Research Subjects
Shafaat Ahmed Bazaz has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Muhammad Masood Ul Hassan
Department of Chemical and Materials Engineering, Pakistan Institute of Engineering & Applied Sciences, P.O. Nilore, Islamabad, Pakistan
3 shared publications - Rana Iqtidar Shakoor
Department of Chemical and Materials Engineering, Pakistan Institute of Engineering & Applied Sciences, P.O. Nilore, Islamabad, Pakistan
3 shared publications - Yongjun Lai
Department of Mechanical and Materials Engineering, Queen’s University, Kingston, ON K7L 3N6, Canada
3 shared publications - Fahimullah Khan
Ghulam Ishaq Khan Institute of Engineering Sciences and Technology
1 shared publication - M. Burnie
Department of Mechanical Engineering, Queens University, Kingston, ON, Canada K7L3N6
1 shared publication - Michael Kraft
KU Leuven
1 shared publication
Latest Publications
- 17 June 2011
- Published by Springer Nature in Microsystem Technologies
- Vol. 17 (8) , 1381-1391
Design and robustness analysis of structurally decoupled 3-DoF MEMS gyroscope in the presence of worst-case process tolerances
- 17 June 2011
- Published by Springer Nature in Microsystem Technologies
- Vol. 17 (8) , 1381-1391
Design and robustness analysis of structurally decoupled 3-DoF MEMS gyroscope in the presence of worst-case process tolerances
- 1 April 2011
- Published by Elsevier in Microelectronics Journal
- Vol. 42 (4) , 585-593
Electrothermally actuated resonant rate gyroscope fabricated using the MetalMUMPs
- 1 April 2011
- Published by Elsevier in Microelectronics Journal
- Vol. 42 (4) , 585-593
Electrothermally actuated resonant rate gyroscope fabricated using the MetalMUMPs
- 28 August 2010
- Published by Springer Nature in Microsystem Technologies
- Vol. 16 (11) , 1957-1965
Design, implementation and testing of electrostatic SOI MUMPs based microgripper
- 28 August 2010
- Published by Springer Nature in Microsystem Technologies
- Vol. 16 (11) , 1957-1965
Design, implementation and testing of electrostatic SOI MUMPs based microgripper
- Open Access
Thermal Actuation Based 3-DoF Non-Resonant Microgyroscope Using MetalMUMPs
High force, large displacement and low voltage consumption are a primary concern for microgyroscopes. The chevron-shaped thermal actuators are unique in terms of high force generation combined with the large displacements at a low operating voltage in comparison with traditional electrostatic actuators. A Nickel based 3-DoF micromachined gyroscope comprising 2-DoF drive mode and 1-DoF sense mode oscillator utilizing the chevron-shaped thermal actuators is presented here. Analytical derivations and finite element simulations are carried out to predict the performance of the proposed device using the thermo-physical properties of electroplated nickel. The device sensitivity is improved by utilizing the dynamical amplification of the oscillation in 2-DoF drive mode using an active-passive mass configuration. A comprehensive theoretical description, dynamics and mechanical design considerations of the proposed gyroscopes model are discussed in detail. Parametric optimization of gyroscope, its prototype modeling and fabrication using MetalMUMPs has also been investigated. Dynamic transient simulation results predicted that the sense mass of the proposed device achieved a drive displacement of 4.1µm when a sinusoidal voltage of 0.5V is applied at 1.77 kHz exhibiting a mechanical sensitivity of 1.7μm /o/s in vacuum. The wide bandwidth frequency response of the 2-DoF drive mode oscillator consists of two resonant peaks and a flat region of 2.11 kHz between the peaks defining the operational frequency region. The sense mode resonant frequency can lie anywhere within this region and therefore the amplitude of the response is insensitive to structural parameter variations, enhancing device robustness against such variations. The proposed device has a size of 2.2 x 2.6 mm2, almost one third in comparison with existing M-DoF vibratory gyroscope with an estimated power consumption of 0.26 Watts. These predicted results illustrate that the chevron-shaped thermal actuator has a large voltage-stroke ratio shifting the paradigm in MEMS gyroscope design from the traditional interdigitated comb drive electrostatic actuator. These actuators have low damping compared to electrostatic comb drive actuators which may result in high quality factor microgyroscopes operating at atmospheric pressure.
Open AccessThermal Actuation Based 3-DoF Non-Resonant Microgyroscope Using MetalMUMPs
High force, large displacement and low voltage consumption are a primary concern for microgyroscopes. The chevron-shaped thermal actuators are unique in terms of high force generation combined with the large displacements at a low operating voltage in comparison with traditional electrostatic actuators. A Nickel based 3-DoF micromachined gyroscope comprising 2-DoF drive mode and 1-DoF sense mode oscillator utilizing the chevron-shaped thermal actuators is presented here. Analytical derivations and finite element simulations are carried out to predict the performance of the proposed device using the thermo-physical properties of electroplated nickel. The device sensitivity is improved by utilizing the dynamical amplification of the oscillation in 2-DoF drive mode using an active-passive mass configuration. A comprehensive theoretical description, dynamics and mechanical design considerations of the proposed gyroscopes model are discussed in detail. Parametric optimization of gyroscope, its prototype modeling and fabrication using MetalMUMPs has also been investigated. Dynamic transient simulation results predicted that the sense mass of the proposed device achieved a drive displacement of 4.1µm when a sinusoidal voltage of 0.5V is applied at 1.77 kHz exhibiting a mechanical sensitivity of 1.7μm /o/s in vacuum. The wide bandwidth frequency response of the 2-DoF drive mode oscillator consists of two resonant peaks and a flat region of 2.11 kHz between the peaks defining the operational frequency region. The sense mode resonant frequency can lie anywhere within this region and therefore the amplitude of the response is insensitive to structural parameter variations, enhancing device robustness against such variations. The proposed device has a size of 2.2 x 2.6 mm2, almost one third in comparison with existing M-DoF vibratory gyroscope with an estimated power consumption of 0.26 Watts. These predicted results illustrate that the chevron-shaped thermal actuator has a large voltage-stroke ratio shifting the paradigm in MEMS gyroscope design from the traditional interdigitated comb drive electrostatic actuator. These actuators have low damping compared to electrostatic comb drive actuators which may result in high quality factor microgyroscopes operating at atmospheric pressure.
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 66-71
Comparative Study on Finite Element Analysis & System Model Extraction for Non-Resonant 3-DoF Microgyroscope
This paper reports a comparative study of full transient start up analysis of a Non-Resonant Micromachined Gyroscope using Finite Element Analysis (FEA) and System Model Extraction (SME) techniques. FEA is a popular numerical technique based on Finite Element Method (FEM) for carrying out different engineering analyses. But one of the major disadvantages of this FEA is its computational time. While running multiple optimization analyses with a FE Solver, it may take days, weeks and possibly months depending on extent of optimization. In this study we initially analyzed the MEMS based microgyro on a device level using FEM. We determined the natural frequencies of the gyro along with the both static and dynamic responses of the gyro. After these device level simulations in FEA we switched to the system level simulation. Using SME we generated system model of the gyro with system level components and run a full transient startup response analysis of the device by incorporating that extracted model in INTELLISUITE circuit simulator SYNPLE. When we compared the computational time required by both techniques, we found that SME with SYNPLE is orders of magnitude faster than FEA.
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 66-71
Comparative Study on Finite Element Analysis & System Model Extraction for Non-Resonant 3-DoF Microgyroscope
This paper reports a comparative study of full transient start up analysis of a Non-Resonant Micromachined Gyroscope using Finite Element Analysis (FEA) and System Model Extraction (SME) techniques. FEA is a popular numerical technique based on Finite Element Method (FEM) for carrying out different engineering analyses. But one of the major disadvantages of this FEA is its computational time. While running multiple optimization analyses with a FE Solver, it may take days, weeks and possibly months depending on extent of optimization. In this study we initially analyzed the MEMS based microgyro on a device level using FEM. We determined the natural frequencies of the gyro along with the both static and dynamic responses of the gyro. After these device level simulations in FEA we switched to the system level simulation. Using SME we generated system model of the gyro with system level components and run a full transient startup response analysis of the device by incorporating that extracted model in INTELLISUITE circuit simulator SYNPLE. When we compared the computational time required by both techniques, we found that SME with SYNPLE is orders of magnitude faster than FEA.