Yong Woo Hong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yong Woo Hong has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
- Young Lan Kwak
Department of Anesthesiology and Pain Medicine, Yonsei University College of Medicine, Seoul 03722, Republic of Korea
31 shared publications Eun Sook Yoo
Department of Anesthesiology, Yonsei University College of Medicine, Seoul, Korea
13 shared publicationsSou Ouk Bang
Department of Anesthesiology and Pain Medicine, Yonsei University College of Medicine, Seoul, Korea
12 shared publications- Young Jun Oh
Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
12 shared publications Sung Yong Park
Department of Anesthesiology and Pain Medicine, Ajou University School of Medicine, Suwon, Korea
9 shared publications- Sang Beom Nam
Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea
8 shared publications
Latest Publications
- Open Access
- 1 January 2012
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 62 (5) , 423-428
Accuracy of cardiac output measurements during off-pump coronary artery bypass grafting: according to the vessel anastomosis sites
During beating heart surgery, the accuracy of cardiac output (CO) measurement techniques may be influenced by several factors. This study was conducted to analyze the clinical agreement among stat CO mode (SCO), continuous CO mode (CCO), arterial pressure waveform-based CO estimation (APCO), and transesophageal Doppler ultrasound technique (UCCO) according to the vessel anastomosis sites. This study was prospectively performed in 25 patients who would be undergoing elective OPCAB. Hemodynamic variables were recorded at the following time points: during left anterior descending (LAD) anastomosis at 1 min and 5 min; during obtuse marginal (OM) anastomosis at 1 min and 5 min: and during right coronary artery (RCA) anastomosis at 1 min and 5 min. The variables measured including the SCO, CCO, APCO, and UCCO. CO measurement techniques showed different correlations according to vessel anastomosis site. However, the percent error observed was higher than the value of 30% postulated by the criteria of Critchley and Critchley during all study periods for all CO measurement techniques. In the beating heart procedure, SCO, CCO and APCO showed different correlations according to the vessel anastomosis sites and did not agree with UCCO. CO values from the various measurement techniques should be interpreted with caution during OPCAB.
- 1 January 2012
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 62 (5) , 423-428
Open AccessAccuracy of cardiac output measurements during off-pump coronary artery bypass grafting: according to the vessel anastomosis sites
During beating heart surgery, the accuracy of cardiac output (CO) measurement techniques may be influenced by several factors. This study was conducted to analyze the clinical agreement among stat CO mode (SCO), continuous CO mode (CCO), arterial pressure waveform-based CO estimation (APCO), and transesophageal Doppler ultrasound technique (UCCO) according to the vessel anastomosis sites. This study was prospectively performed in 25 patients who would be undergoing elective OPCAB. Hemodynamic variables were recorded at the following time points: during left anterior descending (LAD) anastomosis at 1 min and 5 min; during obtuse marginal (OM) anastomosis at 1 min and 5 min: and during right coronary artery (RCA) anastomosis at 1 min and 5 min. The variables measured including the SCO, CCO, APCO, and UCCO. CO measurement techniques showed different correlations according to vessel anastomosis site. However, the percent error observed was higher than the value of 30% postulated by the criteria of Critchley and Critchley during all study periods for all CO measurement techniques. In the beating heart procedure, SCO, CCO and APCO showed different correlations according to the vessel anastomosis sites and did not agree with UCCO. CO values from the various measurement techniques should be interpreted with caution during OPCAB.
- 30 June 2010
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 139 (6) , 1436-1440
Effects of head-up tilt on intrapulmonary shunt fraction and oxygenation during 1-lung ventilation in the lateral decubitus position
- 30 June 2010
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 139 (6) , 1436-1440
Effects of head-up tilt on intrapulmonary shunt fraction and oxygenation during 1-lung ventilation in the lateral decubitus position
- 3 May 2010
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 141 (1) , 151-154
Comparative effects of norepinephrine and vasopressin on internal thoracic arterial graft flow after off-pump coronary artery bypass grafting
- 3 May 2010
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 141 (1) , 151-154
Comparative effects of norepinephrine and vasopressin on internal thoracic arterial graft flow after off-pump coronary artery bypass grafting
- Open Access
- 1 January 2010
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 59 (4) , 283-285
Occlusion of the right subclavian artery after insertion of a transesophageal echocardiography probe in an adult with a vascular ring -A case report-
Park SY, et al. Korean J Anesthesiol. 2010 Oct;59(4):283-285. http://dx.doi.org/10.4097/kjae.2010.59.4.283
- 1 January 2010
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 59 (4) , 283-285
Open AccessOcclusion of the right subclavian artery after insertion of a transesophageal echocardiography probe in an adult with a vascular ring -A case report-
Park SY, et al. Korean J Anesthesiol. 2010 Oct;59(4):283-285. http://dx.doi.org/10.4097/kjae.2010.59.4.283
- Open Access
- 1 January 2010
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 59 (2) , 127-129
Resolution of peripheral artery catheter-induced ischemic injury in infants -Two case reports-
The occurrence of catheter-induced vasospasm of small caliber arteries is a well known complication of arterial catheterization in neonates. However, there is rare publication about these complications in infants. We report infants with peripheral ischemia caused by arterial catheterization of the femoral artery.
- 1 January 2010
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 59 (2) , 127-129
Open AccessResolution of peripheral artery catheter-induced ischemic injury in infants -Two case reports-
The occurrence of catheter-induced vasospasm of small caliber arteries is a well known complication of arterial catheterization in neonates. However, there is rare publication about these complications in infants. We report infants with peripheral ischemia caused by arterial catheterization of the femoral artery.
- 30 January 2009
- Published by Springer Nature in Surgical Endoscopy
- Vol. 23 (10) , 2286-2291
Pressure-controlled versus volume-controlled ventilation during one-lung ventilation in the prone position for robot-assisted esophagectomy
The prone position during robotic esophageal mobilization for minimally invasive esophagectomy (MIE) provides several advantages with regards to operative times, surgeon ergonomics, and surgical view; however, this technique requires one-lung ventilation (OLV). There are no guidelines about ventilatory modes during OLV in the prone position. We investigated the effects of volume-controlled (VCV) and pressure-controlled ventilation (PCV) on oxygenation and intrapulmonary shunt during OLV in the prone position in patients who underwent robot-assisted esophagectomy. Eighteen patients, no major obstructive or restrictive pulmonary disease, were allocated randomly to one of two groups. In the first group (n = 9), OLV was started by VCV and the ventilator was switched to PCV after 30 minutes. In the second group (n = 9), the modes of ventilation were performed in the opposite order in the prone position. Hemodynamic and respiratory variables were obtained during OLV at the end of each ventilatory mode. There were no significant differences in arterial oxygen tension (PaO2), airway pressures, dynamic lung compliance, or physiologic dead space (Vd/Vt) during OLV between PCV and VCV in the prone position. Intrapulmonary shunt (Qs/Qt) was significantly lower with VCV than with PCV during OLV in the prone position (p = 0.044). PCV provides no advantages compared with VCV with regard to respiratory and hemodynamic variables during OLV in the prone position. Either ventilatory mode can be safely used for patients who undergo robot-assisted esophagectomy and who have normal body mass index and preserved pulmonary function.
- 30 January 2009
- Published by Springer Nature in Surgical Endoscopy
- Vol. 23 (10) , 2286-2291
Pressure-controlled versus volume-controlled ventilation during one-lung ventilation in the prone position for robot-assisted esophagectomy
The prone position during robotic esophageal mobilization for minimally invasive esophagectomy (MIE) provides several advantages with regards to operative times, surgeon ergonomics, and surgical view; however, this technique requires one-lung ventilation (OLV). There are no guidelines about ventilatory modes during OLV in the prone position. We investigated the effects of volume-controlled (VCV) and pressure-controlled ventilation (PCV) on oxygenation and intrapulmonary shunt during OLV in the prone position in patients who underwent robot-assisted esophagectomy. Eighteen patients, no major obstructive or restrictive pulmonary disease, were allocated randomly to one of two groups. In the first group (n = 9), OLV was started by VCV and the ventilator was switched to PCV after 30 minutes. In the second group (n = 9), the modes of ventilation were performed in the opposite order in the prone position. Hemodynamic and respiratory variables were obtained during OLV at the end of each ventilatory mode. There were no significant differences in arterial oxygen tension (PaO2), airway pressures, dynamic lung compliance, or physiologic dead space (Vd/Vt) during OLV between PCV and VCV in the prone position. Intrapulmonary shunt (Qs/Qt) was significantly lower with VCV than with PCV during OLV in the prone position (p = 0.044). PCV provides no advantages compared with VCV with regard to respiratory and hemodynamic variables during OLV in the prone position. Either ventilatory mode can be safely used for patients who undergo robot-assisted esophagectomy and who have normal body mass index and preserved pulmonary function.
- Open Access
- 1 January 2009
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 56 (6) , 709-712
Intravalvular regurgitation of the mitral bioprosthetic valve detected by intraoperative transesophageal echocardiography - A case report -
Intraoperative transesophageal echocardiography (IOTEE) is an invaluable diagnostic method for management of cardiac surgical patients, including patients undergoing valve replacement surgery. We report a patient who underwent reoperation for mitral valve replacement due to intravalvular regurgitation following mitral valve replacement with a bioprosthetic valve. The condition was detected by IOTEE and caused by suture entrapment.
- 1 January 2009
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 56 (6) , 709-712
Open AccessIntravalvular regurgitation of the mitral bioprosthetic valve detected by intraoperative transesophageal echocardiography - A case report -
Intraoperative transesophageal echocardiography (IOTEE) is an invaluable diagnostic method for management of cardiac surgical patients, including patients undergoing valve replacement surgery. We report a patient who underwent reoperation for mitral valve replacement due to intravalvular regurgitation following mitral valve replacement with a bioprosthetic valve. The condition was detected by IOTEE and caused by suture entrapment.
- Open Access
- 1 January 2009
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 56 (3) , 345-348
The anesthetic management of a venous bullet embolism to the right ventricle - A case report -
Park SY, et al. Korean J Anesthesiol. 2009 Mar;56(3):345-348. http://dx.doi.org/10.4097/kjae.2009.56.3.345
- 1 January 2009
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 56 (3) , 345-348
Open AccessThe anesthetic management of a venous bullet embolism to the right ventricle - A case report -
Park SY, et al. Korean J Anesthesiol. 2009 Mar;56(3):345-348. http://dx.doi.org/10.4097/kjae.2009.56.3.345
- Open Access
- 1 January 2008
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 54 (6) , 682-684
Compromised Ventilation Caused by Transesophageal Echocardiography Probe in Pediatric Patients Undergoing Congenital Heart Surgery - A case report -
- 1 January 2008
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 54 (6) , 682-684
Open AccessCompromised Ventilation Caused by Transesophageal Echocardiography Probe in Pediatric Patients Undergoing Congenital Heart Surgery - A case report -
- Open Access
- 1 January 2008
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 55 (4) , 479-484
Changes in hemodynamic parameters and regional myocardial perfusion measured by thermal diffusion probe from the infusion of norepinephrine during displacement of porcine beating heart
Lee JW, et al. Korean J Anesthesiol. 2008 Oct;55(4):479-484. http://dx.doi.org/10.4097/kjae.2008.55.4.479
- 1 January 2008
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 55 (4) , 479-484
Open AccessChanges in hemodynamic parameters and regional myocardial perfusion measured by thermal diffusion probe from the infusion of norepinephrine during displacement of porcine beating heart
Lee JW, et al. Korean J Anesthesiol. 2008 Oct;55(4):479-484. http://dx.doi.org/10.4097/kjae.2008.55.4.479