Marianne Gauthier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marianne Gauthier has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Ingrid Leguerney
Laboratoire Imagerie par Résonance Magnétique Médicale et Multi-Modalités, Unité Mixte de Recherche 8081, Centre National de la Recherche Scientifique, Paris-Sud 11 University, Gustave Roussy Institute, Villejuif, France
2 shared publicationsNathalie Lassau
Imaging Department, Ultrasonography Unit, Gustave Roussy Institute, Villejuif, France
2 shared publicationsPierre Peronneau
Laboratoire Imagerie par Résonance Magnétique Médicale et Multi-Modalités, Unité Mixte de Recherche 8081, Centre National de la Recherche Scientifique, Paris-Sud 11 University, Gustave Roussy Institute, Villejuif, France
2 shared publicationsAlain Roche
1 shared publicationFarid Tabarout
Laboratoire Imagerie par Résonance Magnétique Médicale et Multi-Modalités, Unité Mixte de Recherche 8081, Centre National de la Recherche Scientifique, Paris-Sud 11 University, Gustave Roussy Institute, Villejuif, France
1 shared publicationJessie Thalmensi
1 shared publication
Latest Publications
- 1 April 2012
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 31 (4) , 595-608
Assessment of Quantitative Perfusion Parameters by Dynamic Contrast-Enhanced Sonography Using a Deconvolution Method
Objectives The purpose of this study was to investigate the impact of the arterial input on perfusion parameters measured using dynamic contrast-enhanced sonography combined with a deconvolution met...
- 1 April 2012
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 31 (4) , 595-608
Assessment of Quantitative Perfusion Parameters by Dynamic Contrast-Enhanced Sonography Using a Deconvolution Method
Objectives The purpose of this study was to investigate the impact of the arterial input on perfusion parameters measured using dynamic contrast-enhanced sonography combined with a deconvolution met...
- Open Access
- 1 January 2011
- Published by Baishideng Publishing Group Inc. in World Journal of Radiology
- Vol. 3 (3) , 70-81
Estimation of intra-operator variability in perfusion parameter measurements using DCE-US
To investigate intra-operator variability of semi-quantitative perfusion parameters using dynamic contrast-enhanced ultrasonography (DCE-US), following bolus injections of SonoVue(®). The in vitro experiments were conducted using three in-house sets up based on pumping a fluid through a phantom placed in a water tank. In the in vivo experiments, B16F10 melanoma cells were xenografted to five nude mice. Both in vitro and in vivo, images were acquired following bolus injections of the ultrasound contrast agent SonoVue(®) (Bracco, Milan, Italy) and using a Toshiba Aplio(®) ultrasound scanner connected to a 2.9-5.8 MHz linear transducer (PZT, PLT 604AT probe) (Toshiba, Japan) allowing harmonic imaging ("Vascular Recognition Imaging") involving linear raw data. A mathematical model based on the dye-dilution theory was developed by the Gustave Roussy Institute, Villejuif, France and used to evaluate seven perfusion parameters from time-intensity curves. Intra-operator variability analyses were based on determining perfusion parameter coefficients of variation (CV). In vitro, different volumes of SonoVue(®) were tested with the three phantoms: intra-operator variability was found to range from 2.33% to 23.72%. In vivo, experiments were performed on tumor tissues and perfusion parameters exhibited values ranging from 1.48% to 29.97%. In addition, the area under the curve (AUC) and the area under the wash-out (AUWO) were two of the parameters of great interest since throughout in vitro and in vivo experiments their variability was lower than 15.79%. AUC and AUWO appear to be the most reliable parameters for assessing tumor perfusion using DCE-US as they exhibited the lowest CV values.
- 1 January 2011
- Published by Baishideng Publishing Group Inc. in World Journal of Radiology
- Vol. 3 (3) , 70-81
Open AccessEstimation of intra-operator variability in perfusion parameter measurements using DCE-US
To investigate intra-operator variability of semi-quantitative perfusion parameters using dynamic contrast-enhanced ultrasonography (DCE-US), following bolus injections of SonoVue(®). The in vitro experiments were conducted using three in-house sets up based on pumping a fluid through a phantom placed in a water tank. In the in vivo experiments, B16F10 melanoma cells were xenografted to five nude mice. Both in vitro and in vivo, images were acquired following bolus injections of the ultrasound contrast agent SonoVue(®) (Bracco, Milan, Italy) and using a Toshiba Aplio(®) ultrasound scanner connected to a 2.9-5.8 MHz linear transducer (PZT, PLT 604AT probe) (Toshiba, Japan) allowing harmonic imaging ("Vascular Recognition Imaging") involving linear raw data. A mathematical model based on the dye-dilution theory was developed by the Gustave Roussy Institute, Villejuif, France and used to evaluate seven perfusion parameters from time-intensity curves. Intra-operator variability analyses were based on determining perfusion parameter coefficients of variation (CV). In vitro, different volumes of SonoVue(®) were tested with the three phantoms: intra-operator variability was found to range from 2.33% to 23.72%. In vivo, experiments were performed on tumor tissues and perfusion parameters exhibited values ranging from 1.48% to 29.97%. In addition, the area under the curve (AUC) and the area under the wash-out (AUWO) were two of the parameters of great interest since throughout in vitro and in vivo experiments their variability was lower than 15.79%. AUC and AUWO appear to be the most reliable parameters for assessing tumor perfusion using DCE-US as they exhibited the lowest CV values.