SDSteffen J. Diehl

Steffen J. Diehl

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Steffen J. Diehl has a total of 65 co-authors. Here are the top co-authors by number of shared publications:

  • Nils Rathmann

    Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany

    7 shared publications
  • Stefan Oswald Schoenberg

    Department of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Medical Faculty Mannheim, Heidelberg University, D-68167 Mannheim, Baden-Württemberg, Germany

    4 shared publications
  • Maliha Sadick

    Institute for Clinical Radiology and Nuclear Medicine, University-Medical-Center Mannheim, University-Medical-Center Mannheim, Germany

    3 shared publications
  • Michael Kostrzewa

    Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany

    3 shared publications
  • Michael Kostrzewa

    Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany

    3 shared publications
  • Stefan O. Schoenberg

    Institute of Clinical Radiology and Nuclear Medicine, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim, Germany

    3 shared publications

Latest Publications

  • Open Access

    Selective Internal Radiation Therapy (SIRT) for SDH-Deficient GIST Demonstrates Encouraging Durable Response Rates: An International Multicenter Case Series

    by Zachary T. Berman, Peter Hohenberger, Ramesh Bulusu, Steven C. Rose, Paul T. Fanta, Jonathan Evans, Steffen Diehl, Franka Menge, Nasim Ali, Jason K. Sicklick

    Background/Objectives: Succinate dehydrogenase (SDH)-deficient gastrointestinal stromal tumors (GISTs) are a rare subgroup of GISTs and respond poorly to conventional systemic therapies. This study describes long-term outcomes after yttrium-90 (Y-90) selective internal radiation therapy (SIRT) for progression of unresectable SDH-deficient GIST hepatic metastases. Methods: We performed a retrospective review of consecutive patients treated with SIRT at three tertiary referral centers in Europe and the United States. Data collection included demographics, tumor profiling, prior therapies, Y-90 dosimetry approach, imaging response, adverse events, and long-term outcomes. Results: Twelve patients (66.7% female) with a median age of 27 years (range, 17–57 years) were included. One patient had a complete response (8.3%) and seven had partial responses (58.3%) by modified Response Evaluation Criteria in Solid Tumors. Four patients (33.3%) had tumor shrinkage that did not meet partial response criteria. The objective response rate was 66.7%, with a disease control rate of 100%. One grade 3 or higher adverse event was observed (cholecystitis requiring cholecystectomy). At a median follow-up of 32 months (range, 3–77 months), two patients experienced disease progression. Median overall survival was not reached, with one death during follow-up. Conclusions: SIRT appears safe and effective for patients with progressive, unresectable SDH-deficient GIST hepatic metastases, with durable responses and limited serious toxicity. These findings suggest that SDH-deficient GIST may be more sensitive to radiation than previously appreciated and that SIRT may be a useful liver-directed approach for patients with limited systemic options.

  • Open Access

    Spatial Omics Imaging of Fresh-Frozen Tissue and Routine FFPE Histopathology of a Single Cancer Needle Core Biopsy: A Freezing Device and Multimodal Workflow

    by Miriam F. Rittel, Stefan Schmidt, Cleo-Aron Weis, Emrullah Birgin, Björn van Marwick, Matthias Rädle, Steffen J. Diehl, Nuh N. Rahbari, Alexander Marx, Carsten Hopf

    The complex molecular alterations that underlie cancer pathophysiology are studied in depth with omics methods using bulk tissue extracts. For spatially resolved tissue diagnostics using needle biopsy cores, however, histopathological analysis using stained FFPE tissue and the immunohistochemistry (IHC) of a few marker proteins is currently the main clinical focus. Today, spatial omics imaging using MSI or IRI is an emerging diagnostic technology for the identification and classification of various cancer types. However, to conserve tissue-specific metabolomic states, fast, reliable, and precise methods for the preparation of fresh-frozen (FF) tissue sections are crucial. Such methods are often incompatible with clinical practice, since spatial metabolomics and the routine histopathology of needle biopsies currently require two biopsies for FF and FFPE sampling, respectively. Therefore, we developed a device and corresponding laboratory and computational workflows for the multimodal spatial omics analysis of fresh-frozen, longitudinally sectioned needle biopsies to accompany standard FFPE histopathology of the same biopsy core. As a proof-of-concept, we analyzed surgical human liver cancer specimens using IRI and MSI with precise co-registration and, following FFPE processing, by sequential clinical pathology analysis of the same biopsy core. This workflow allowed for a spatial comparison between different spectral profiles and alterations in tissue histology, as well as a direct comparison for histological diagnosis without the need for an extra biopsy.


  • Open Access

    Contralateral Liver Hypertrophy and Oncological Outcome Following Radioembolization with 90Y-Microspheres: A Systematic Review

    by Emrullah Birgin, Erik Rasbach, Steffen Seyfried, Nils Rathmann, Steffen J. Diehl, Stefan O. Schoenberg, Christoph Reissfelder, Nuh N. Rahbari

    Radioembolization with 90Y-microspheres has been reported to induce contralateral liver hypertrophy with simultaneous ipsilateral control of tumor growth. The aim of the present systematic review was to summarize the evidence of contralateral liver hypertrophy and oncological outcome following unilateral treatment with radioembolization. A systematic literature search using the MEDLINE, EMBASE, and Cochrane libraries for studies published between 2008 and 2020 was performed. A total of 16 studies, comprising 602 patients, were included. The median kinetic growth rate per week of the contralateral liver lobe was 0.7% and declined slightly over time. The local tumor control was 84%. Surgical resection after radioembolization was carried out in 109 out of 362 patients (30%). Although the available data suggest that radioembolization prior to major hepatectomy is safe with a promising oncological outcome, the definitive role of radioembolization requires assessment within controlled clinical trials.


  • Irreversible Electroporation for Surgical Renal Masses in Solitary Kidneys: Short-Term Interventional and Functional Outcome

    by Steffen J. Diehl, Nils Rathmann, Michael Kostrzewa, Manuel Ritter, Arman Smakic, Stefan O. Schoenberg, Maximilian C. Kriegmair


    • 28 August 2016
      • Vol. 30  (5) , 651-5

    Automated Vessel Segmentation in Dual Energy Computed Tomography Data of the Pelvis and Lower Extremities.

    by Michael Kostrzewa, Nils Rathmann, Jürgen Hesser, Kurt Huck, Stefan O Schönberg, Steffen J Diehl

    To evaluate the clinical feasibility of a newly developed, fully automatic vessel segmentation software with automatic structured bone elimination (ASBE) using graph-matching and subvoxel analysis. Dual energy computed tomography angiography (DECTA) data of 108 vessel segments were evaluated using the ASBE software and a commercial software against the digital subtraction angiography (DSA) standard of reference. Using the ASBE software, sensitivity increased from 87.1% to 96.8% and data concordance with DSA increased from 64.5% to 88.6%, whereas specificity slightly decreased (79.2% vs. 87%) compared to the commercial software. Data concordance between ASBE software and DSA was especially high in severely stenosed (grade of stenosis >75%) blood vessels. ASBE showed good concordance with the DSA standard of reference and non-inferiority compared to the commercial segmentation software. The main advantage of the ASBE software lies in its full automation and, thus, lower susceptibility to user prone errors.

    • 28 August 2016
      • Vol. 30  (5) , 707-12

    Benefit of Patients with an Early and Progressed State of Hepatocellular Carcinoma Treated with Drug-eluting Beads.

    by Nils Rathmann, Maliha Sadick, Bjoern Rathmann, Michael Kostrzewa, Christel Weiss, Stefan O Schoenberg, Steffen J Diehl, Christoph Antoni

    To evaluate drug-eluting beads (DEB) for transarterial chemoembolization (TACE) in patients with Barcelona Clinic Liver Cancer (BCLC) A to D suffering from hepatocellular carcinoma. The progression-free interval (PFI), survival and laboratory findings of 46 patients were retrospectively analyzed after DEB TACE. The mean survival interval was 16.93 months. The BCLC A/B group had significantly (p=0.01) longer survival compared to C/D: 20.44 and 10.36 months. Mean PFI was 10.75 months with a significantly (p=0.002) longer PFI of the BCLC A/B group (12.71 months) compared to BCLC C/D (3.91 months). In terms of possible adverse events (AEs) significant changes (p<0.05) were observed in cholinesterase, white blood cells, alkaline phosphatase and C-reactive protein. Mean survival and PFI results in the BCLC A/B patient group were comparable to historical controls. In addition, the results suggest that patients with BCLC stage C/D also benefited from DEB TACE.


    • 1 June 2016
      • Vol. 36  (6) , 2961-6

    Semiautomatic Whole-lesion Apparent Diffusion Coefficient Assessment for Early Prediction of Liver Tumor Response to Radioembolization.

    by Nils Rathmann, Johannes Budjan, Fatinah Mari, Robert Grimm, Ulrike Attenberger, Michael Kostrzewa, Maliha Sadick, Stefan O Schoenberg, Steffen J Diehl

    To evaluate volume-based apparent diffusion coefficient (ADCVOL) values for early prediction of therapy response after radioembolization (RE) of primary and secondary liver malignancies using a semiautomatic, image analysis software prototype. In a retrospective analysis, 74 target lesions were assessed in terms of therapy response 1 month after RE using magnetic resonance imaging. Changes of the diameter of the target lesions, the mean ADC value in a representative single-slice region of interest (ADCROI) and mean ADCVOL were correlated. The median progression-free interval (PFI) of patients overall was 3.5±5.9 months. PFI in patients with an ADCVOL increase was statistically significantly longer than in patients with an ADCVOL decrease (mean PFI=6.5 vs. 2.5 months; p=0.0374). No correlation between PFI and early changes in lesion diameter or ADCROI was found. Semiautomatic, software-based ADC volume measurements seem to offer a clinically valuable parameter for early prediction of therapy response in patients after RE.

  • Radiation exposure of the interventional radiologist during percutaneous biopsy using a multiaxis interventional C-arm CT system with 3D laser guidance: a phantom study

    by Nils Rathmann, Michael Kostrzewa, Kerim Kara, Soenke Bartling, Holger Haubenreisser, Stefan O Schoenberg, Steffen J Diehl

    Objective:Evaluation of absolute radiation exposure values for interventional radiologists (IRs) using a multiaxis interventional flat-panel C-arm cone beam CT (CBCT) system with three-dimensional laser guidance for biopsy in a triple-modality, abdominal phantom.Methods:In the phantom, eight lesions were punctured in two different angles (in- and out-of-plane) using CBCT. One C-arm CT scan was performed to plan the intervention and one for post-procedural evaluation. Thermoluminescent dosemeters (TLDs) were used for dose measurement at the level of the eye lens, umbilicus and ankles on a pole representing the IRs. All measurements were performed without any lead protection. In addition, the dose–area product (DAP) and air kerma at the skin entrance point was documented.Results:Mean radiation values of all TLDs were 190 µSv for CBCT (eye lens: 180 µS, umbilicus: 230 µSv, ankle: 150 µSv) without a significant difference (p > 0.005) between in- and out-of-plane biopsies. In terms of radiation exposure of the...


  • Accuracy of percutaneous soft-tissue interventions using a multi-axis, C-arm CT system and 3D laser guidance

    by Michael Kostrzewa, Nils Rathmann, Kerim Kara, Stefan O. Schoenberg, Steffen J. Diehl