MSMaliha Sadick

Maliha Sadick

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Maliha Sadick has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • Steffen J. Diehl

    Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany

    3 shared publications
  • Christel Weiss

    Department of Biomathematics, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany

    2 shared publications
  • Christoph Düber

    Department of Interventional and Clinical Radiology, University Hospital Mainz, Mainz, Gemany

    2 shared publications
  • Michael Kostrzewa

    Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany

    2 shared publications
  • Nils Rathmann

    Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany

    2 shared publications
  • Stefan O Schoenberg

    Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany

    2 shared publications

Latest Publications

  • Einseitige Armschwellung – Leitsymptom einer Gefäßanomalie

    by Felix Harder, Stefan O. Schönberg, Maliha Sadick

    Bei der persistierenden linken Vena cava superior (PLVCS) handelt es sich um eine seltene vaskuläre Aberration. Ihre Prävalenz beträgt in der Normalbevölkerung bis zu 0,5 % bzw. betrifft bis zu 10 % der Patienten mit kongenitalen kardialen Anomalien. In 80 – 90 % erfolgt die Mündung in den Sinus coronarius (SC) (Musci RL et al. J Cardiovasc Echogr 2017; 27: 149 – 152). Die PLVCS stellt nicht nur eine anatomische Auffälligkeit dar, sondern geht außerdem mit klinischen, radiologischen sowie interventionellen Besonderheiten einher. Wir präsentieren einen Fall, welcher eine PLVCS mit einer klinisch unklaren, isolierten rechtsseitigen Armschwellung verbindet.

    • 28 August 2016
      • Vol. 30  (5) , 707-12

    Benefit of Patients with an Early and Progressed State of Hepatocellular Carcinoma Treated with Drug-eluting Beads.

    by Nils Rathmann, Maliha Sadick, Bjoern Rathmann, Michael Kostrzewa, Christel Weiss, Stefan O Schoenberg, Steffen J Diehl, Christoph Antoni

    To evaluate drug-eluting beads (DEB) for transarterial chemoembolization (TACE) in patients with Barcelona Clinic Liver Cancer (BCLC) A to D suffering from hepatocellular carcinoma. The progression-free interval (PFI), survival and laboratory findings of 46 patients were retrospectively analyzed after DEB TACE. The mean survival interval was 16.93 months. The BCLC A/B group had significantly (p=0.01) longer survival compared to C/D: 20.44 and 10.36 months. Mean PFI was 10.75 months with a significantly (p=0.002) longer PFI of the BCLC A/B group (12.71 months) compared to BCLC C/D (3.91 months). In terms of possible adverse events (AEs) significant changes (p<0.05) were observed in cholinesterase, white blood cells, alkaline phosphatase and C-reactive protein. Mean survival and PFI results in the BCLC A/B patient group were comparable to historical controls. In addition, the results suggest that patients with BCLC stage C/D also benefited from DEB TACE.


    • 1 June 2016
      • Vol. 36  (6) , 2961-6

    Semiautomatic Whole-lesion Apparent Diffusion Coefficient Assessment for Early Prediction of Liver Tumor Response to Radioembolization.

    by Nils Rathmann, Johannes Budjan, Fatinah Mari, Robert Grimm, Ulrike Attenberger, Michael Kostrzewa, Maliha Sadick, Stefan O Schoenberg, Steffen J Diehl

    To evaluate volume-based apparent diffusion coefficient (ADCVOL) values for early prediction of therapy response after radioembolization (RE) of primary and secondary liver malignancies using a semiautomatic, image analysis software prototype. In a retrospective analysis, 74 target lesions were assessed in terms of therapy response 1 month after RE using magnetic resonance imaging. Changes of the diameter of the target lesions, the mean ADC value in a representative single-slice region of interest (ADCROI) and mean ADCVOL were correlated. The median progression-free interval (PFI) of patients overall was 3.5±5.9 months. PFI in patients with an ADCVOL increase was statistically significantly longer than in patients with an ADCVOL decrease (mean PFI=6.5 vs. 2.5 months; p=0.0374). No correlation between PFI and early changes in lesion diameter or ADCROI was found. Semiautomatic, software-based ADC volume measurements seem to offer a clinically valuable parameter for early prediction of therapy response in patients after RE.

  • Effect of Time-of-Flight Technique on the Diagnostic Performance of 18F-FDG PET/CT for Assessment of Lymph Node Metastases in Head and Neck Squamous Cell Carcinoma

    by Chun-Yan Li, Sarah Klohr, Haneen Sadick, Christel Weiss, Karl Hoermann, Stefan O. Schoenberg, Maliha Sadick

    Precise assessment of lymph node metastases is critical to the treatment outcome and overall survival of patients with head and neck squamous cell carcinoma (HNSCC). The purpose of this study was to investigate the effect of time-of-flight (TOF) technique on the diagnostic performance of 18F-FDG PET/CT for assessment of lymph node metastases in HNSCC patients. Methods: In 39 patients with an initial diagnosis of HNSCC, preoperative staging 18F-FDG PET/CT was performed to assess lymph node metastases before surgery and histologic verification. Potential lymph node metastases were evaluated and documented separately for the right and left neck in accordance with the head and neck lymph node level classification. Two experienced readers measured lesion volume and uptake for every PET-positive lymph node. Sensitivity, specificity, image quality, and the PET characterization of the lesion (benign or malignant) were compared between different reconstruction methods (TOF PET and standard high-definition PET) and matrices for both readers. Results: TOF PET significantly increased the maximal standardized uptake value (SUVmax) but had no significant effect on lesion volume. However, a higher SUVmax did not result in a significant increase in small-lesion detection. Sensitivity and image quality were slightly improved with TOF PET but not significantly so. Matrix, on the other hand, had a significant effect on detected lesion numbers, sensitivity, and image quality. Conclusion: For preoperative assessment of lymph node metastases in HNSCC, 18F-FDG PET/CT using TOF technique increases SUVmax in lesions and improves image quality but has no significant impact on small-lesion detectability.


  • Twelve-month Results of the EverFlex Stent in the Superficial Femoral Artery

    by Steffen J. Diehl, Felix Gerblich, Susanne Jochum, Kurt Huck, Michael Keese, Stefan O. Schoenberg, Maliha Sadick


  • Morphologic and Dynamic Renal Imaging With Assessment of Glomerular Filtration Rate in a pcy-Mouse Model Using a Clinical 3.0 Tesla Scanner

    by Maliha Sadick, Daniel Schock, Bettina Kraenzlin, Norbert Gretz, Stefan O. Schoenberg, Henrik J. Michaely

    OBJECTIVE Morphologic and dynamic renal imaging is necessary for characterization of kidney function in renal insufficiency. Assessment of renal perfusion and the glomerular filtration rate (GFR) are essential, as the serum creatinine level and urea are not sensitive at an early stage of kidney damage. Currently available GFR estimation methods are time consuming, expensive, and lead to radiation exposure for the patient. Therefore, the aim was to determine the feasibility of morphologic and contrast-enhanced dynamic magnetic resonance imaging for GFR assessment in pcy (polycystic kidneys and fibrosis) mice, using a clinical 3.0 Tesla scanner. Fourteen pcy-mice were anesthetized and an internal jugular vein catheter was implanted to which a dedicated extension tube with a 0.28 mm inner diameter was connected, filled with 1:100 microL diluted gadobutrol (Gadovist Bayer Schering Pharma, Berlin, Germany). Imaging of the mice was performed with a dedicated 8-element mouse coil (Rapid Biomedical, Rimpar, Germany) plugged into a clinical 32-channel 3.0 Tesla magnetic resonance-scanner (Magnetom Verio, Siemens Medical Solution, Erlangen, Germany). In this study, different morphologic sequences comprising a T1-w 3D volume-interpolated breathhold examination, T2-w 2D half-Fourier acquired turbo spin echo (HASTE), T2-w 2D BLADE-TSE with fat saturation, and a T2-w 3D SPACE were acquired. The dynamic sequence performed for assessment of GFR, was a 2D SR-Turbo FLASH sequence. Image analysis and data assessment was performed by 2 radiologists who were experienced in assessment of human kidney disease. A 3-point scale for visual assessment of renal cystic changes in the pcy-mice was applied. The appearance of cysts, considering a detailed demarcation of the cyst with an enhancing rim and a hypointense core, were assessed as detailed: (1) faint (2) and not to be differentiated, (3) findings in the morphologic sequences. Quantitative parameters of renal function (cortex plasma flow mL/100 mL/min, cortex plasma volume mL/100 mL, and PT sec) were fitted to a 2-compartment model and compared with blood samples of creatinine and urea. Histologic progression of cysts and fibrosis in the pcy-mice was analyzed. The T2-w 3D SPACE and T1-w 3D volume-interpolated breathhold examination sequence post contrast with thinnest slice thickness of 1 to 1.2 mm were well suited for delineation of the kidneys with detailed demarcation of the cysts (image quality score: 1.14 +/- 0.37 and 1.2 +/- 0.70, respectively). The T2-w 2D BLADE-TSE proved feasible, too (image quality score: 1.28 +/- 0.59). The T2-w 2D HASTE sequence with minimally achievable slice thickness of 2 mm was not suitable for morphologic assessment (image quality score: 2.9 +/- 0.37). The HASTE sequence suffered from blurring artifacts which further decreased the conspicuity of small cystic changes. The 2D SR-Turbo FLASH sequence showed the renal first pass of the contrast agent and enabled assessment of GFR. The data after time resolved 2D SR-Turbo FLASH perfusion analysis was used for GFR evaluation and demonstrated better GFR values in the young pcy-mice (0.558 mL/min) compared with the older pcy-mice (0.066 mL/min). Application of dedicated coils with a clinical 3.0 Tesla magnetic resonance-scanner have proved feasible for morphologic and dynamic renal imaging with assessment of GFR in pcy-mice.


  • Leitsymptom Akutes Abdomen

    by M. Sadick, C. Böhm, M. Gehrlein, C. Düber

  • Cross-Sectional Imaging Combined with 3D-MR Angiography (3D-MRA): Diagnostic Tool for Preoperative Vascular Assessment of Head and Neck Tumors

    by Maliha Sadick, Haneen Sadick, Karl Hörmann, Christoph Düber, Steffen J. Diehl

    Background: Head and neck cancer accounts for 5% of all malignancies worldwide. The presence of lymph node metastases and vascular infiltration influence patient outcome. This prospective study describes the preoperative morphologic assessment of the vascular status of patients with head and neck tumors by means of high spatial resolution and extended coverage of the arterial and venous system reaching from the supra-aortic region to the skull base. Patients and Methods: Crosssectional imaging combined with contrast-enhanced 3Dmaximum intensity projection MR angiography (3DMRA) was applied using a dedicated head and neck coil with a 4-channel panorama array system interface to assess vascular involvement in patients with suspected head and neck cancer. 32 patients underwent preoperative assessment by magnetic resonance imaging (MRI). The results were then correlated with surgical and histological findings. Results: 3 of the 32 patients (9%) demonstrated involvement of the arterial system. In 2 of these 3 cases, MRA correctly predicted the arterial status, while in 1 case it gave a false negative result. 11 of the 32 patients (34%) presented with involvement of the venous system. 10 cases showed complete concordance between the findings of the MR venography and the intraoperative status, while in 1 case a false negative result was produced. Conclusion: In patients with suspected head and neck tumors, 3D-MRA in combination with cross sectional imaging is a valuable diagnostic tool for the detection of vascular involvement.