Seung Ho Jeong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Seung Ho Jeong has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Byung-Hoon Oh
Korea Atomic Energy Research Institute, Daejeon, South Korea
5 shared publications - Doo-Hee Chang
Division of Nuclear Fusion Engineering & Technology Development, Korea Atomic Energy Research Institute, Daejeon 305-353, Republic of Korea
5 shared publications - Kwang-Won Lee
Department of Biotechnology, Korea University, Seoul 02841, Republic of Korea
5 shared publications Dae-Sik Chang
4 shared publicationsJung-Tae Jin
4 shared publications- Tae-Seong Kim
Department of Electronics and Information Convergence Engineering, Kyung Hee University, Yongin, Republic of Korea
4 shared publications
Latest Publications
- 11 December 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (2) , 02B316
Improvement of a plasma uniformity of the 2nd ion source of KSTAR neutral beam injector
The 2nd ion source of KSTAR (Korea Superconducting Tokamak Advanced Research) NBI (Neutral Beam Injector) had been developed and operated since last year. A calorimetric analysis revealed that the heat load of the back plate of the ion source is relatively higher than that of the 1st ion source of KSTAR NBI. The spatial plasma uniformity of the ion source is not good. Therefore, we intended to identify factors affecting the uniformity of a plasma density and improve it. We estimated the effects of a direction of filament current and a magnetic field configuration of the plasma generator on the plasma uniformity. We also verified that the operation conditions of an ion source could change a uniformity of the plasma density of an ion source.
- 11 December 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (2) , 02B316
Improvement of a plasma uniformity of the 2nd ion source of KSTAR neutral beam injector
The 2nd ion source of KSTAR (Korea Superconducting Tokamak Advanced Research) NBI (Neutral Beam Injector) had been developed and operated since last year. A calorimetric analysis revealed that the heat load of the back plate of the ion source is relatively higher than that of the 1st ion source of KSTAR NBI. The spatial plasma uniformity of the ion source is not good. Therefore, we intended to identify factors affecting the uniformity of a plasma density and improve it. We estimated the effects of a direction of filament current and a magnetic field configuration of the plasma generator on the plasma uniformity. We also verified that the operation conditions of an ion source could change a uniformity of the plasma density of an ion source.
- 1 February 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (2) , 02B102
First neutral beam injection experiments on KSTAR tokamak
The first neutral beam (NB) injection system of the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak was partially completed in 2010 with only 1/3 of its full design capability, and NB heating experiments were carried out during the 2010 KSTAR operation campaign. The ion source is composed of a JAEA bucket plasma generator and a KAERI large multi-aperture accelerator assembly, which is designed to deliver a 1.5 MW, NB power of deuterium at 95 keV. Before the beam injection experiments, discharge, and beam extraction characteristics of the ion source were investigated. The ion source has good beam optics in a broad range of beam perveance. The optimum perveance is 1.1–1.3 μP, and the minimum beam divergence angle measured by the Doppler shift spectroscopy is 0.8°. The ion species ratio is D+:D2+:D3+ = 75:20:5 at beam current density of 85 mA/cm2. The arc efficiency is more than 1.0 A/kW. In the 2010 KSTAR campaign, a deuterium NB power of 0.7–1.5 MW was successfully injected into the KSTAR plasma with a beam energy of 70–90 keV. L-H transitions were observed within a wide range of beam powers relative to a threshold value. The edge pedestal formation in the Ti and Te profiles was verified through CES and electron cyclotron emission diagnostics. In every deuterium NB injection, a burst of D-D neutrons was recorded, and increases in the ion temperature and plasma stored energy were found.
- 1 February 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (2) , 02B102
First neutral beam injection experiments on KSTAR tokamak
The first neutral beam (NB) injection system of the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak was partially completed in 2010 with only 1/3 of its full design capability, and NB heating experiments were carried out during the 2010 KSTAR operation campaign. The ion source is composed of a JAEA bucket plasma generator and a KAERI large multi-aperture accelerator assembly, which is designed to deliver a 1.5 MW, NB power of deuterium at 95 keV. Before the beam injection experiments, discharge, and beam extraction characteristics of the ion source were investigated. The ion source has good beam optics in a broad range of beam perveance. The optimum perveance is 1.1–1.3 μP, and the minimum beam divergence angle measured by the Doppler shift spectroscopy is 0.8°. The ion species ratio is D+:D2+:D3+ = 75:20:5 at beam current density of 85 mA/cm2. The arc efficiency is more than 1.0 A/kW. In the 2010 KSTAR campaign, a deuterium NB power of 0.7–1.5 MW was successfully injected into the KSTAR plasma with a beam energy of 70–90 keV. L-H transitions were observed within a wide range of beam powers relative to a threshold value. The edge pedestal formation in the Ti and Te profiles was verified through CES and electron cyclotron emission diagnostics. In every deuterium NB injection, a burst of D-D neutrons was recorded, and increases in the ion temperature and plasma stored energy were found.
- 12 August 2011
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 59 (2) , 275-280
Arc Discharge Characteristics of a Long Pulse Ion Source for the KSTAR Neutral Beam Injector
- 12 August 2011
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 59 (2) , 275-280
Arc Discharge Characteristics of a Long Pulse Ion Source for the KSTAR Neutral Beam Injector
- 1 June 2011
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 50 (6R) , 066302
Results of Beam Extraction Performance for the KSTAR Neutral Beam Injector
The first neutral beam injector (NBI-1) has been developed for the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak. The first long pulse ion source (LPIS-1) has been installed on the NBI-1 for an auxiliary heating and current drive of KSTAR plasmas. The performance of ion and neutral beam extractions in the LPIS-1 was investigated initially on the KSTAR NBI-1 system, prior to the neutral beam injection into the main plasmas. The ion source consists of a magnetic bucket plasma generator with multipole cusp fields and a set of prototype tetrode accelerators with circular apertures. The inner volume of the plasma generator and accelerator column in the LPIS-1 is approximately 123 L. Design requirements for the ion source were a 120 kV/65 A deuterium beam and a 300 s pulse length. The extraction of ion beams was initiated by the formation of arc plasmas in the LPIS-1, called the arc-beam extraction method. A stable ion beam extraction of the LPIS-1 was achieved up to 85 kV/32 A for a 5 s pulse length and 80 kV/25 A for a 14 s pulse length. An optimum beam perveance of 1.15 µperv was observed at an acceleration voltage of 60 kV. Neutralization efficiency was measured by a water-flow calorimetry (WFC) method using a calorimeter and the operation of a bending magnet. The full-energy species of ion beams were detected by using the diagnostic method of optical multichannel analyzer (OMA). An arc efficiency of the LPIS was 0.6–1.1 A/kW depending on the operating conditions of arc discharge. A neutral beam power of ~1.0 MW must be sufficiently injected into the KSTAR plasmas from the LPIS-1 at a beam energy of 80 keV.
- 1 June 2011
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 50 (6R) , 066302
Results of Beam Extraction Performance for the KSTAR Neutral Beam Injector
The first neutral beam injector (NBI-1) has been developed for the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak. The first long pulse ion source (LPIS-1) has been installed on the NBI-1 for an auxiliary heating and current drive of KSTAR plasmas. The performance of ion and neutral beam extractions in the LPIS-1 was investigated initially on the KSTAR NBI-1 system, prior to the neutral beam injection into the main plasmas. The ion source consists of a magnetic bucket plasma generator with multipole cusp fields and a set of prototype tetrode accelerators with circular apertures. The inner volume of the plasma generator and accelerator column in the LPIS-1 is approximately 123 L. Design requirements for the ion source were a 120 kV/65 A deuterium beam and a 300 s pulse length. The extraction of ion beams was initiated by the formation of arc plasmas in the LPIS-1, called the arc-beam extraction method. A stable ion beam extraction of the LPIS-1 was achieved up to 85 kV/32 A for a 5 s pulse length and 80 kV/25 A for a 14 s pulse length. An optimum beam perveance of 1.15 µperv was observed at an acceleration voltage of 60 kV. Neutralization efficiency was measured by a water-flow calorimetry (WFC) method using a calorimeter and the operation of a bending magnet. The full-energy species of ion beams were detected by using the diagnostic method of optical multichannel analyzer (OMA). An arc efficiency of the LPIS was 0.6–1.1 A/kW depending on the operating conditions of arc discharge. A neutral beam power of ~1.0 MW must be sufficiently injected into the KSTAR plasmas from the LPIS-1 at a beam energy of 80 keV.
- 1 October 2010
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 81 (10) , 10D922
Electron cyclotron emission diagnostics on KSTAR tokamak
A new electron cyclotron emission (ECE) diagnostics system was installed for the Second Korea Superconducting Tokamak Advanced Research (KSTAR) campaign. The new ECE system consists of an ECE collecting optics system, an overmode circular corrugated waveguide system, and 48 channel heterodyne radiometer with the frequency range of 110–162 GHz. During the 2 T operation of the KSTAR tokamak, the electron temperatures as well as its radial profiles at the high field side were measured and sawtooth phenomena were also observed. We also discuss the effect of a window on in situ calibration.
- 1 October 2010
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 81 (10) , 10D922
Electron cyclotron emission diagnostics on KSTAR tokamak
A new electron cyclotron emission (ECE) diagnostics system was installed for the Second Korea Superconducting Tokamak Advanced Research (KSTAR) campaign. The new ECE system consists of an ECE collecting optics system, an overmode circular corrugated waveguide system, and 48 channel heterodyne radiometer with the frequency range of 110–162 GHz. During the 2 T operation of the KSTAR tokamak, the electron temperatures as well as its radial profiles at the high field side were measured and sawtooth phenomena were also observed. We also discuss the effect of a window on in situ calibration.
- 15 March 2008
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 52 (9(3)) , 687-693
Development of a High-Current, Long-Pulse Ion Source
- 15 March 2008
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 52 (9(3)) , 687-693
Development of a High-Current, Long-Pulse Ion Source
- 15 September 2007
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 51 (3)
Development of a Prototype KSTAR Neutral Beam System
- 15 September 2007
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 51 (3)
Development of a Prototype KSTAR Neutral Beam System
- 7 April 2005
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 14 (2) , 336-341
Arc discharge efficiency of a multi-megawatt long pulse ion source for the KSTAR neutral beam injector
- 7 April 2005
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 14 (2) , 336-341
Arc discharge efficiency of a multi-megawatt long pulse ion source for the KSTAR neutral beam injector