Sajeesh Kumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sajeesh Kumar has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Ian Jeffery Constable
Lions Eye Institute, University of Western Australia, Perth, Australia
6 shared publications Kanagasingam Yogesan
Centre of Excellence in e‐Medicine, Lions Eye Institute, University of Western Australia, Nedlands WA, Australia
5 shared publicationsK Yogesan
Centre of Excellence in e-Medicine, University of Western Australia, Perth, Australia
3 shared publications- Kanagasingam Yogesan
Centre of Excellence in e-Medicine, Lions Eye Institute, University of Western Australia, Nedlands, Australia
3 shared publications Max Bulsara
School of Population Health, University of Western Australia, Nedlands WA, Australia E‐mail
3 shared publicationsWilliam Morgan
Lions Eye Institute, Perth, Western Australia, Australia
2 shared publications
Latest Publications
- 1 November 2008
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 91 (6) , 545-550
Automated determination of distance visual acuity: towards teleophthalmology services
The aim of this study was to evaluate the visual acuity scores of a computer-based visual function testing (CVFT) system. The automated chart uses logMAR notation (logarithm of the minimum angle of resolution) and randomised tilting E as optotype. The test was conducted using a laptop computer. This prospective, clinic-based, test validation study was based on a model of repeatability in two observations. The right eyes of a total of 104 participants were randomly tested with both CVFT and the manual, gold standard Early Treatment of Diabetic Retinopathy Study (ETDRS) chart. The mean difference between CVFT and ETDRS was -0.01+/-0.11 (SD) logMAR units. The Spearman Rank correlation coefficient (r) between the absolute difference and the average was 0.35. The average time for testing one eye was 54.7+/-11.89 seconds. The mean difference between two consecutive, repeated CVFT tests in the same eye was 0.02+/-0.07 logMAR units (paired t-test p=0.046). A novel, automated visual acuity testing application is reported. This automated system should be a useful tool for mass screening of visual impairment in rural and remote regions with its ease of use and shorter testing time.
- 1 November 2008
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 91 (6) , 545-550
Automated determination of distance visual acuity: towards teleophthalmology services
The aim of this study was to evaluate the visual acuity scores of a computer-based visual function testing (CVFT) system. The automated chart uses logMAR notation (logarithm of the minimum angle of resolution) and randomised tilting E as optotype. The test was conducted using a laptop computer. This prospective, clinic-based, test validation study was based on a model of repeatability in two observations. The right eyes of a total of 104 participants were randomly tested with both CVFT and the manual, gold standard Early Treatment of Diabetic Retinopathy Study (ETDRS) chart. The mean difference between CVFT and ETDRS was -0.01+/-0.11 (SD) logMAR units. The Spearman Rank correlation coefficient (r) between the absolute difference and the average was 0.35. The average time for testing one eye was 54.7+/-11.89 seconds. The mean difference between two consecutive, repeated CVFT tests in the same eye was 0.02+/-0.07 logMAR units (paired t-test p=0.046). A novel, automated visual acuity testing application is reported. This automated system should be a useful tool for mass screening of visual impairment in rural and remote regions with its ease of use and shorter testing time.
- 15 February 2008
- Published by Springer Nature in Eye
- Vol. 23 (3) , 652-660
Telemedical diagnosis of anterior segment eye diseases: validation of digital slit-lamp still images
Purpose This study compared digital images from a portable slit-lamp camera with 35 mm slit-lamp photographs and traditional ophthalmic assessments in anterior segment disorder's detection. Methods A total of 196 patients (392 eyes) were recruited from an anterior segment ophthalmology clinic. Each patient underwent an examination by an anterior segment ophthalmologist. Two to three standardized views of 640 × 480 pixels digital images (portable digital slit-lamp camera) and 35 mm photographic slides (Zeiss slit-lamp camera) were taken after the examination. The same ophthalmologist reviewed these images in a masked fashion. Two other masked graders also assessed the digital images. The presence or absence of 33 specific findings was noted at each examination. Results Digital images showed moderate to excellent agreement to clinical findings (κ 0.45–0.82) in areas other than lid pathologies. Lens findings from digital images had moderate to good agreement with the clinical gold standard (unweighted κ 0.43–0.65, sensitivity 59–77%, specificity 86–94%). Gross cornea signs were well detected with digital images, (κ 0.72–0.85, sensitivity 67–100%, specificity 98–99). More subtle corneal, conjunctival and lid abnormalities were not identified well. The statistical figures were very similar to the above-mentioned figures when the 35-mm film results were compared to clinical diagnoses. The two image formats showed better agreement when compared to each other than when either is compared with clinical findings. Conclusion Diagnoses using digital slit-lamp images were comparable to diagnosis using 35 mm photographic slides for some anterior segment abnormalities.
- 15 February 2008
- Published by Springer Nature in Eye
- Vol. 23 (3) , 652-660
Telemedical diagnosis of anterior segment eye diseases: validation of digital slit-lamp still images
Purpose This study compared digital images from a portable slit-lamp camera with 35 mm slit-lamp photographs and traditional ophthalmic assessments in anterior segment disorder's detection. Methods A total of 196 patients (392 eyes) were recruited from an anterior segment ophthalmology clinic. Each patient underwent an examination by an anterior segment ophthalmologist. Two to three standardized views of 640 × 480 pixels digital images (portable digital slit-lamp camera) and 35 mm photographic slides (Zeiss slit-lamp camera) were taken after the examination. The same ophthalmologist reviewed these images in a masked fashion. Two other masked graders also assessed the digital images. The presence or absence of 33 specific findings was noted at each examination. Results Digital images showed moderate to excellent agreement to clinical findings (κ 0.45–0.82) in areas other than lid pathologies. Lens findings from digital images had moderate to good agreement with the clinical gold standard (unweighted κ 0.43–0.65, sensitivity 59–77%, specificity 86–94%). Gross cornea signs were well detected with digital images, (κ 0.72–0.85, sensitivity 67–100%, specificity 98–99). More subtle corneal, conjunctival and lid abnormalities were not identified well. The statistical figures were very similar to the above-mentioned figures when the 35-mm film results were compared to clinical diagnoses. The two image formats showed better agreement when compared to each other than when either is compared with clinical findings. Conclusion Diagnoses using digital slit-lamp images were comparable to diagnosis using 35 mm photographic slides for some anterior segment abnormalities.
- 11 April 2007
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 35 (3) , 237-243
Glaucoma screening: analysis of conventional and telemedicine‐friendly devices
Purpose: Portable, telemedicine‐friendly devices offer novel opportunity for screening and monitoring glaucoma in the remote and rural regions of the world. This study examines the effective combination of telemedicine‐friendly screening devices for detection of glaucoma in relation with conventional, hospital‐based devices.Methods: A total of 399 eyes were screened with telemedicine‐friendly devices and conventional, hospital‐based devices such as ophthalmoscope, tonometer and perimeter.Results: Combination of age and family history of glaucoma alone has a sensitivity of 35.6% (specificity 94.2%, area under the curve 0.81, correctly classified 81.1%) and an addition of telemedicine‐friendly or conventional visual field tests optimized the sensitivity to 91.1% (specificity 93.6%, area under the curve 0.95, correctly classified 93%). Analysis indicates good agreement between vertical cup‐to‐disc ratio by ophthalmoscopy and digital image reading. An addition of intraocular pressure test does not change sensitivity (35.6%) and specificity (94.2%).Conclusion: This study indicates that evaluations of cup‐to‐disc ratio and visual field, using telemedicine‐friendly devices, are most useful tools in screening for glaucoma. When used together these devices may be an alternative for conventional glaucoma screenings.
- 11 April 2007
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 35 (3) , 237-243
Glaucoma screening: analysis of conventional and telemedicine‐friendly devices
Purpose: Portable, telemedicine‐friendly devices offer novel opportunity for screening and monitoring glaucoma in the remote and rural regions of the world. This study examines the effective combination of telemedicine‐friendly screening devices for detection of glaucoma in relation with conventional, hospital‐based devices.Methods: A total of 399 eyes were screened with telemedicine‐friendly devices and conventional, hospital‐based devices such as ophthalmoscope, tonometer and perimeter.Results: Combination of age and family history of glaucoma alone has a sensitivity of 35.6% (specificity 94.2%, area under the curve 0.81, correctly classified 81.1%) and an addition of telemedicine‐friendly or conventional visual field tests optimized the sensitivity to 91.1% (specificity 93.6%, area under the curve 0.95, correctly classified 93%). Analysis indicates good agreement between vertical cup‐to‐disc ratio by ophthalmoscopy and digital image reading. An addition of intraocular pressure test does not change sensitivity (35.6%) and specificity (94.2%).Conclusion: This study indicates that evaluations of cup‐to‐disc ratio and visual field, using telemedicine‐friendly devices, are most useful tools in screening for glaucoma. When used together these devices may be an alternative for conventional glaucoma screenings.
- 13 September 2006
- Published by Springer Nature
- p. 275-277
Postscript
- 13 September 2006
- Published by Springer Nature
- p. 133-138
Internet-Based Electronic Eye Care Consultations: Patient Perspective
- 13 September 2006
- Published by Springer Nature
- p. 133-138
Internet-Based Electronic Eye Care Consultations: Patient Perspective
- 9 August 2006
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 34 (7) , 666-670
Telemedicine‐friendly, portable tonometers: an evaluation for intraocular pressure screening
Purpose: To evaluate the intraocular pressure (IOP) readings from two portable, telemedicine‐friendly tonometers for suitability in glaucoma screening.Methods: 213 eyes of 107 consenting patients attending an eye clinic were tested with an I‐care tonometer and a Pulsair‐Easy Eye puff‐air tonometer. Gold standard IOP was measured with a Goldmann applanation tonometer (GAT). Effect of central corneal thickness, anterior chamber depth and refractive errors on IOP measurements were also analysed.Results: The mean difference of IOP by GAT and both the portable tonometers was ± 2.2 mmHg. The analysis indicates minimal difference between IOP readings of both the portable tonometers. The mean difference between two consecutive readings by I‐care was 0.01 mmHg. Using 21 mmHg as a threshold for suspected glaucoma, both the portable digital tonometers reported a sensitivity of 38% and specificity of >95%. In the subjects studied, central corneal thickness had statistically significant influence on IOP measurements while refractive errors and anterior chamber depth had no significant influence on IOP measurements with any tonometry.Conclusion: The IOP readings by both portable tonometers are comparable and were within clinically acceptable range from GAT. These portable tonometers are useful tools for IOP screening.
- 9 August 2006
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 34 (7) , 666-670
Telemedicine‐friendly, portable tonometers: an evaluation for intraocular pressure screening
Purpose: To evaluate the intraocular pressure (IOP) readings from two portable, telemedicine‐friendly tonometers for suitability in glaucoma screening.Methods: 213 eyes of 107 consenting patients attending an eye clinic were tested with an I‐care tonometer and a Pulsair‐Easy Eye puff‐air tonometer. Gold standard IOP was measured with a Goldmann applanation tonometer (GAT). Effect of central corneal thickness, anterior chamber depth and refractive errors on IOP measurements were also analysed.Results: The mean difference of IOP by GAT and both the portable tonometers was ± 2.2 mmHg. The analysis indicates minimal difference between IOP readings of both the portable tonometers. The mean difference between two consecutive readings by I‐care was 0.01 mmHg. Using 21 mmHg as a threshold for suspected glaucoma, both the portable digital tonometers reported a sensitivity of 38% and specificity of >95%. In the subjects studied, central corneal thickness had statistically significant influence on IOP measurements while refractive errors and anterior chamber depth had no significant influence on IOP measurements with any tonometry.Conclusion: The IOP readings by both portable tonometers are comparable and were within clinically acceptable range from GAT. These portable tonometers are useful tools for IOP screening.
- Open Access
- 24 March 2006
- Published by Springer Nature in Eye
- Vol. 20 (12) , 1455-1456
Nanophthalmology: new frontier in fighting blindness?
- 24 March 2006
- Published by Springer Nature in Eye
- Vol. 20 (12) , 1455-1456
Open AccessNanophthalmology: new frontier in fighting blindness?
- 28 February 2006
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 141 (2) , 429
Internet-based eye care: VISION 2020
- 28 February 2006
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 141 (2) , 429
Internet-based eye care: VISION 2020
- 1 January 2006
- Published by SAGE Publications in Journal of Telemedicine and Telecare
- Vol. 12 (1) , 19-22
Remote ophthalmology services: cost comparison of telemedicine and alternative service delivery options
We calculated the cost of an established tele-ophthalmology service, from a health-provider's perspective, and compared this with the cost of three other existing eye-care service delivery options. During a 12-month study period, 118 persons took part in the tele-ophthalmology consultations between a rural clinic located approximately 900 km from the Lions Eye Institute in Perth. The variable costs of tele-ophthalmology were $166.89 (Australian dollars) per patient, and the alternatives cost $445.96, $271.48 and $665.44 per patient. Tele-ophthalmology incurred a set-up cost of $13,340. The threshold at which tele-ophthalmology became cheaper than any of the alternative options occurred at a workload of 128 patients. Tele-ophthalmology offers a viable alternative to conventional eye-care service in rural and remote areas.
- 1 January 2006
- Published by SAGE Publications in Journal of Telemedicine and Telecare
- Vol. 12 (1) , 19-22
Remote ophthalmology services: cost comparison of telemedicine and alternative service delivery options
We calculated the cost of an established tele-ophthalmology service, from a health-provider's perspective, and compared this with the cost of three other existing eye-care service delivery options. During a 12-month study period, 118 persons took part in the tele-ophthalmology consultations between a rural clinic located approximately 900 km from the Lions Eye Institute in Perth. The variable costs of tele-ophthalmology were $166.89 (Australian dollars) per patient, and the alternatives cost $445.96, $271.48 and $665.44 per patient. Tele-ophthalmology incurred a set-up cost of $13,340. The threshold at which tele-ophthalmology became cheaper than any of the alternative options occurred at a workload of 128 patients. Tele-ophthalmology offers a viable alternative to conventional eye-care service in rural and remote areas.