KYKanagasingam Yogesan

Kanagasingam Yogesan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kanagasingam Yogesan has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Evaluation of Internet-based eye care delivery

    by Kanagasingam Yogesan, Sajeesh Kumar, Mei-Ling Tay-Kearney, Ian Constable

    We have developed a system for tele-ophthalmology that uses low bandwidth data transmission via the Internet. The online system has been tested in two different trials, with specialist advice provided from Perth. The first trial concerned referrals from Indonesia. Approximately 250 consultations were provided in the first two years. The referral rate rose to an average of 10 consultations per month. 25% of patients avoided intended air travel to Australia, 20% were operated on locally in Indonesia and the other 55% travelled to Australia where they were given advice about the surgery required, cost and length of stay. In the second trial, referrals were received from a regional hospital in Western Australia. Approximately 200 consultations were provided. About 4% of the patients were transferred to Perth for treatment, 38% of the patients needed follow-up, 8% were treated by local medical officers according to specialist advice, and the rest were cleared of any disease. Problems of reimbursement and doctors’ indemnity will need to be overcome if the online service is to become sustainable.


  • Postscript

    by Kanagasingam Yogesan, Sajeesh Kumar, Leonard Goldschmidt, Jorge Cuadros

  • Internet-Based Electronic Eye Care Consultations: Patient Perspective

    by Sajeesh Kumar, Kanagasingam Yogesan, Beth Hudson, Mei-Ling Tay-Kearney


  • Diabetic Retinopathy Screening: What Model is Appropriate?

    by Chris J. Barry, Ian L. McAllister, Ian J. Constable, Kanagasingam Yogesan

  • Introduction to Teleophthalmology

    by Sajeesh Kumar, Kanagasingam Yogesan


    • 1 December 2003
      • Vol. 51  (4) , 295-6

    Tele-ophthalmology in India. Is it here to stay?

    by K R Sajeesh Kumar, Kanagasingam Yogesan, Ian J Constable


  • Telemedicine Screening for Diabetic Retinopathy

    by Kanagasingam Yogesan, Ian J. Constable, Ian Chan


  • Open Access

    Online eye care in prisons in Western Australia

    by K Yogesan, C Henderson, C J Barry, I J Constable

    In prisons, prison medical officers provide general medical care. However, if specialist care is needed then the prisoner is transported to a specialist medical centre. This is a costly procedure and prison escapes occur during transportation. We have tested our Internet-based eye care system in prisons in Western Australia. Medical and ophthalmic history, visual acuity and intraocular pressure were stored in a browser-based multimedia database. Digital images of the retina and the external eye were recorded and transmitted to a central server. Based on the medical data and the digital images, the specialist ophthalmologist could provide a diagnosis within 24 h. Eleven patients (mean age 48, range 30–82 years) were reviewed during two separate visits to a maximum-security prison in Western Australia. Our main aim was to train prison medical officers and nurses to operate the portable ophthalmic imaging instruments and to use the Internet-based eye care system. The outcome of the pilot study indicated that considerable savings could be made in transport costs and the security risk could be reduced. The Ministry of Justice in Western Australia has decided to implement telemedicine services to provide regular ophthalmic consultation to its prisons.


  • Telemedicine Screening of Diabetic Retinopathy Using a Hand-Held Fundus Camera

    by Kanagasingam Yogesan, Ian J. Constable, Chris J. Barry, Robert H. Eikelboom, Ian L. McAllister, Mei-Ling Tay-Kearney

    The objective was to evaluate digital images of the retina from a handheld fundus camera (Nidek NM-100) for suitability in telemedicine screening of diabetic retinopathy. A handheld fundus camera (Nidek) and a standard fundus camera (Zeiss) were used to photograph 49 eyes from 25 consecutive patients attending our diabetic clinic. One patient had cataracts, making it impossible to get a quality image of one of the eyes (retina). The Nidek images were digitized, compressed, and stored in a Fujix DF-10M digitizer supplied with the camera. The digital images and the photographs were presented separately in a random order to three ophthalmologists. The quality of the images was ranked as good, acceptable or unacceptable for diabetic retinopathy diagnosis. The images were also evaluated for the presence of microaneurysms, blot hemorrhages, exudates, fibrous tissue, previous photocoagulation, and new vessel formation. κ Values were computed for agreement between the photographs and digital images. Overall agreement between the photographs and digital images was poor (κ < 0.30). On average, only 24% of the digital images were graded as being good quality and 56% as having an acceptable quality. However, 93% of the photographs were graded as good-quality images for diagnosis. The results indicate that the digital images from the handheld fundus camera may not be suitable for diagnosis of diabetic retinopathy. The images shown on the liquid crystal display (LCD) screen of the camera were of good quality. However, the images produced by the digitizer (Fujix DF-10M) attached to the camera were not as good as the images shown on the LCD screen. A better digitizing system may produce better quality images from the Nidek camera.


  • International transmission of tele-ophthalmology images

    by K Yogesan, I J Constable, W Morgan, D Y Soebadi

    Tele-ophthalmic consultations were conducted between a hospital in East Java, Indonesia, and an ophthalmology centre in Perth, Western Australia. Twenty-two eyes of 14 subjects were screened for glaucoma using a hand-held fundus camera. Optic disc images comprised 267 x 234 pixels at 24 bit/pixel (187 kByte). The images were compressed and stored together with patient information on a laptop computer. The images were then transmitted to Perth using either a mobile phone or a satellite phone, taking 170 s or 240 s, respectively. Images were also compressed to five different compression levels before transmission. At a compression ratio of 1 : 5, the images were 36 kByte in size and took 29 s to transmit by mobile phone and 60 s by satellite phone. To measure the loss of quality, the root mean square error was calculated for each colour component, comparing the transmitted and original images. The coefficients of variation were 10% (green), 15% (blue) and 22% (red). The images received in Perth were considered to be of excellent quality and readily interpreted by ophthalmologists in terms of the likely presence of glaucoma.