Kanagasingam Yogesan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kanagasingam Yogesan has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Ian Jeffery Constable
Lions Eye Institute, University of Western Australia, Perth, Australia
9 shared publications - Robert Henry Eikelboom
Ear Science Institute Australia
3 shared publications - Sajeesh Kumar
Centre of Excellence in e-Medicine, Lions Eye Institute, University of Western Australia, Nedlands WA, Australia
3 shared publications C J Barry
Centre for E-Health, Lions Eye Institute, University of Western Australia
2 shared publicationsIan L. McAllister
University of Western Australia
2 shared publicationsMei-Ling Tay-Kearney
Centre of Excellence in e-Medicine, Lions Eye Institute, University of Western Australia, Nedlands, Australia
2 shared publications
Latest Publications
- 1 November 2006
- Published by SAGE Publications in Journal of Telemedicine and Telecare
- Vol. 12 (3_suppl) , 103-104
Evaluation of Internet-based eye care delivery
We have developed a system for tele-ophthalmology that uses low bandwidth data transmission via the Internet. The online system has been tested in two different trials, with specialist advice provided from Perth. The first trial concerned referrals from Indonesia. Approximately 250 consultations were provided in the first two years. The referral rate rose to an average of 10 consultations per month. 25% of patients avoided intended air travel to Australia, 20% were operated on locally in Indonesia and the other 55% travelled to Australia where they were given advice about the surgery required, cost and length of stay. In the second trial, referrals were received from a regional hospital in Western Australia. Approximately 200 consultations were provided. About 4% of the patients were transferred to Perth for treatment, 38% of the patients needed follow-up, 8% were treated by local medical officers according to specialist advice, and the rest were cleared of any disease. Problems of reimbursement and doctors’ indemnity will need to be overcome if the online service is to become sustainable.
- 1 November 2006
- Published by SAGE Publications in Journal of Telemedicine and Telecare
- Vol. 12 (3_suppl) , 103-104
Evaluation of Internet-based eye care delivery
We have developed a system for tele-ophthalmology that uses low bandwidth data transmission via the Internet. The online system has been tested in two different trials, with specialist advice provided from Perth. The first trial concerned referrals from Indonesia. Approximately 250 consultations were provided in the first two years. The referral rate rose to an average of 10 consultations per month. 25% of patients avoided intended air travel to Australia, 20% were operated on locally in Indonesia and the other 55% travelled to Australia where they were given advice about the surgery required, cost and length of stay. In the second trial, referrals were received from a regional hospital in Western Australia. Approximately 200 consultations were provided. About 4% of the patients were transferred to Perth for treatment, 38% of the patients needed follow-up, 8% were treated by local medical officers according to specialist advice, and the rest were cleared of any disease. Problems of reimbursement and doctors’ indemnity will need to be overcome if the online service is to become sustainable.
- 13 September 2006
- Published by Springer Nature
- p. 275-277
Postscript
- 13 September 2006
- Published by Springer Nature
- p. 133-138
Internet-Based Electronic Eye Care Consultations: Patient Perspective
- 13 September 2006
- Published by Springer Nature
- p. 133-138
Internet-Based Electronic Eye Care Consultations: Patient Perspective
- 13 September 2006
- Published by Springer Nature
- p. 87-98
Diabetic Retinopathy Screening: What Model is Appropriate?
- 13 September 2006
- Published by Springer Nature
- p. 87-98
Diabetic Retinopathy Screening: What Model is Appropriate?
- 1 January 2002
- Published by Springer Nature in Disease Management and Health Outcomes
- Vol. 10 (11) , 673-678
Telemedicine Screening for Diabetic Retinopathy
- 1 January 2002
- Published by Springer Nature in Disease Management and Health Outcomes
- Vol. 10 (11) , 673-678
Telemedicine Screening for Diabetic Retinopathy
- Open Access
- 1 December 2001
- Published by SAGE Publications in Journal of Telemedicine and Telecare
- Vol. 7 (2_suppl) , 63-64
Online eye care in prisons in Western Australia
In prisons, prison medical officers provide general medical care. However, if specialist care is needed then the prisoner is transported to a specialist medical centre. This is a costly procedure and prison escapes occur during transportation. We have tested our Internet-based eye care system in prisons in Western Australia. Medical and ophthalmic history, visual acuity and intraocular pressure were stored in a browser-based multimedia database. Digital images of the retina and the external eye were recorded and transmitted to a central server. Based on the medical data and the digital images, the specialist ophthalmologist could provide a diagnosis within 24 h. Eleven patients (mean age 48, range 30–82 years) were reviewed during two separate visits to a maximum-security prison in Western Australia. Our main aim was to train prison medical officers and nurses to operate the portable ophthalmic imaging instruments and to use the Internet-based eye care system. The outcome of the pilot study indicated that considerable savings could be made in transport costs and the security risk could be reduced. The Ministry of Justice in Western Australia has decided to implement telemedicine services to provide regular ophthalmic consultation to its prisons.
- 1 December 2001
- Published by SAGE Publications in Journal of Telemedicine and Telecare
- Vol. 7 (2_suppl) , 63-64
Open AccessOnline eye care in prisons in Western Australia
In prisons, prison medical officers provide general medical care. However, if specialist care is needed then the prisoner is transported to a specialist medical centre. This is a costly procedure and prison escapes occur during transportation. We have tested our Internet-based eye care system in prisons in Western Australia. Medical and ophthalmic history, visual acuity and intraocular pressure were stored in a browser-based multimedia database. Digital images of the retina and the external eye were recorded and transmitted to a central server. Based on the medical data and the digital images, the specialist ophthalmologist could provide a diagnosis within 24 h. Eleven patients (mean age 48, range 30–82 years) were reviewed during two separate visits to a maximum-security prison in Western Australia. Our main aim was to train prison medical officers and nurses to operate the portable ophthalmic imaging instruments and to use the Internet-based eye care system. The outcome of the pilot study indicated that considerable savings could be made in transport costs and the security risk could be reduced. The Ministry of Justice in Western Australia has decided to implement telemedicine services to provide regular ophthalmic consultation to its prisons.
- 1 June 2000
- Published by SAGE Publications in Telemedicine Journal
- Vol. 6 (2) , 219-223
Telemedicine Screening of Diabetic Retinopathy Using a Hand-Held Fundus Camera
The objective was to evaluate digital images of the retina from a handheld fundus camera (Nidek NM-100) for suitability in telemedicine screening of diabetic retinopathy. A handheld fundus camera (Nidek) and a standard fundus camera (Zeiss) were used to photograph 49 eyes from 25 consecutive patients attending our diabetic clinic. One patient had cataracts, making it impossible to get a quality image of one of the eyes (retina). The Nidek images were digitized, compressed, and stored in a Fujix DF-10M digitizer supplied with the camera. The digital images and the photographs were presented separately in a random order to three ophthalmologists. The quality of the images was ranked as good, acceptable or unacceptable for diabetic retinopathy diagnosis. The images were also evaluated for the presence of microaneurysms, blot hemorrhages, exudates, fibrous tissue, previous photocoagulation, and new vessel formation. κ Values were computed for agreement between the photographs and digital images. Overall agreement between the photographs and digital images was poor (κ < 0.30). On average, only 24% of the digital images were graded as being good quality and 56% as having an acceptable quality. However, 93% of the photographs were graded as good-quality images for diagnosis. The results indicate that the digital images from the handheld fundus camera may not be suitable for diagnosis of diabetic retinopathy. The images shown on the liquid crystal display (LCD) screen of the camera were of good quality. However, the images produced by the digitizer (Fujix DF-10M) attached to the camera were not as good as the images shown on the LCD screen. A better digitizing system may produce better quality images from the Nidek camera.
- 1 June 2000
- Published by SAGE Publications in Telemedicine Journal
- Vol. 6 (2) , 219-223
Telemedicine Screening of Diabetic Retinopathy Using a Hand-Held Fundus Camera
The objective was to evaluate digital images of the retina from a handheld fundus camera (Nidek NM-100) for suitability in telemedicine screening of diabetic retinopathy. A handheld fundus camera (Nidek) and a standard fundus camera (Zeiss) were used to photograph 49 eyes from 25 consecutive patients attending our diabetic clinic. One patient had cataracts, making it impossible to get a quality image of one of the eyes (retina). The Nidek images were digitized, compressed, and stored in a Fujix DF-10M digitizer supplied with the camera. The digital images and the photographs were presented separately in a random order to three ophthalmologists. The quality of the images was ranked as good, acceptable or unacceptable for diabetic retinopathy diagnosis. The images were also evaluated for the presence of microaneurysms, blot hemorrhages, exudates, fibrous tissue, previous photocoagulation, and new vessel formation. κ Values were computed for agreement between the photographs and digital images. Overall agreement between the photographs and digital images was poor (κ < 0.30). On average, only 24% of the digital images were graded as being good quality and 56% as having an acceptable quality. However, 93% of the photographs were graded as good-quality images for diagnosis. The results indicate that the digital images from the handheld fundus camera may not be suitable for diagnosis of diabetic retinopathy. The images shown on the liquid crystal display (LCD) screen of the camera were of good quality. However, the images produced by the digitizer (Fujix DF-10M) attached to the camera were not as good as the images shown on the LCD screen. A better digitizing system may produce better quality images from the Nidek camera.
- 2 February 2000
- Published by SAGE Publications in Journal of Telemedicine and Telecare
- Vol. 6 (1) , 41-44
International transmission of tele-ophthalmology images
Tele-ophthalmic consultations were conducted between a hospital in East Java, Indonesia, and an ophthalmology centre in Perth, Western Australia. Twenty-two eyes of 14 subjects were screened for glaucoma using a hand-held fundus camera. Optic disc images comprised 267 x 234 pixels at 24 bit/pixel (187 kByte). The images were compressed and stored together with patient information on a laptop computer. The images were then transmitted to Perth using either a mobile phone or a satellite phone, taking 170 s or 240 s, respectively. Images were also compressed to five different compression levels before transmission. At a compression ratio of 1 : 5, the images were 36 kByte in size and took 29 s to transmit by mobile phone and 60 s by satellite phone. To measure the loss of quality, the root mean square error was calculated for each colour component, comparing the transmitted and original images. The coefficients of variation were 10% (green), 15% (blue) and 22% (red). The images received in Perth were considered to be of excellent quality and readily interpreted by ophthalmologists in terms of the likely presence of glaucoma.
- 2 February 2000
- Published by SAGE Publications in Journal of Telemedicine and Telecare
- Vol. 6 (1) , 41-44
International transmission of tele-ophthalmology images
Tele-ophthalmic consultations were conducted between a hospital in East Java, Indonesia, and an ophthalmology centre in Perth, Western Australia. Twenty-two eyes of 14 subjects were screened for glaucoma using a hand-held fundus camera. Optic disc images comprised 267 x 234 pixels at 24 bit/pixel (187 kByte). The images were compressed and stored together with patient information on a laptop computer. The images were then transmitted to Perth using either a mobile phone or a satellite phone, taking 170 s or 240 s, respectively. Images were also compressed to five different compression levels before transmission. At a compression ratio of 1 : 5, the images were 36 kByte in size and took 29 s to transmit by mobile phone and 60 s by satellite phone. To measure the loss of quality, the root mean square error was calculated for each colour component, comparing the transmitted and original images. The coefficients of variation were 10% (green), 15% (blue) and 22% (red). The images received in Perth were considered to be of excellent quality and readily interpreted by ophthalmologists in terms of the likely presence of glaucoma.