Tomokazu Matsue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tomokazu Matsue has a total of 190 co-authors. Here are the top co-authors by number of shared publications:
Hitoshi Shiku
Department of Applied Chemistry, Graduate School of Engineering Tohoku University Sendai 980‐8579 Japan
54 shared publications- Kosuke Ino
Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan
44 shared publications Yasufumi Takahashi
Division of Electrical Engineering and Computer Science Kanazawa University Kanazawa 920‐1192 Japan
16 shared publications- Isamu Uchida
Department of Applied Chemistry, Graduate School of Engineering, Tohoku University, Aramaki-Aoba 07, Aoba-ku, Sendai 980-8579, Japan
14 shared publications - Tomoyuki Yasukawa
Graduate School of Science, University of Hyogo, 3-2-1, Kouto, Kamigori-cho, Ako-gun, Hyogo, Japan
14 shared publications - Hitoshi Shiku
Graduate School of Engineering, Tohoku University
13 shared publications
Latest Publications
- 5 February 2019
- Published by Oxford University Press (OUP) in Chemistry Letters
- Vol. 48 (2) , 102-105
N- and Fe-containing Carbon Films Prepared by Calcination of Polydopamine Composites Self-assembled at Air/Water Interface for Oxygen Reduction Reaction
Here we report the synthesis and electrocatalytic properties of polymer films containing nitrogen and iron. The films were prepared by calcination of polydopamine, polyethyleneimine and iron. The composite films were self-assembled at the air/water interface, and exhibited higher activity for the oxygen reduction reaction than glassy carbon or calcined polydopamine films. These results suggest that such calcined composite films have potential applications as cathodes in polymer electrolyte fuel cells.
- 5 February 2019
- Published by Oxford University Press (OUP) in Chemistry Letters
- Vol. 48 (2) , 102-105
N- and Fe-containing Carbon Films Prepared by Calcination of Polydopamine Composites Self-assembled at Air/Water Interface for Oxygen Reduction Reaction
Here we report the synthesis and electrocatalytic properties of polymer films containing nitrogen and iron. The films were prepared by calcination of polydopamine, polyethyleneimine and iron. The composite films were self-assembled at the air/water interface, and exhibited higher activity for the oxygen reduction reaction than glassy carbon or calcined polydopamine films. These results suggest that such calcined composite films have potential applications as cathodes in polymer electrolyte fuel cells.
- Open Access
- 10 December 2018
- Published by Wiley in Electroanalysis
- Vol. 30 (12)
Cover Picture: Simultaneous and Selective Imaging of Dopamine and Glutamate Using an Enzyme‐modified Large‐scale Integration (LSI)‐based Amperometric Electrochemical Device (Electroanalysis 12/2018)
- 10 December 2018
- Published by Wiley in Electroanalysis
- Vol. 30 (12)
Open AccessCover Picture: Simultaneous and Selective Imaging of Dopamine and Glutamate Using an Enzyme‐modified Large‐scale Integration (LSI)‐based Amperometric Electrochemical Device (Electroanalysis 12/2018)
- 27 September 2018
- Published by Wiley in Electroanalysis
- Vol. 30 (12) , 2841-2846
Simultaneous and Selective Imaging of Dopamine and Glutamate Using an Enzyme‐modified Large‐scale Integration (LSI)‐based Amperometric Electrochemical Device
Since neurotransmitters play critical roles in nervous systems, the imaging techniques that can visualize them are needed. This communication describes the development of a method for simultaneous imaging of dopamine (DA) and glutamate (Glu), typical neurotransmitters, using enzyme‐modified large‐scale integration (LSI)‐based amperometric devices, referred to “Bio‐LSI”. The DA was detected by using direct electrochemical oxidation while Glu was measured by using an indirect electrochemical reaction involving glutamate oxidase (GluOx)/horseradish peroxidase (HRP) and osmium (Os) polymer‐modified electrodes. The Os‐HRP polymer was modified on designated sensor electrodes through electrodeposition. The selective and simultaneous imaging of neurotransmitters such as DA and Glu was achieved by applying the enzyme‐modified Bio‐LSI.
- 27 September 2018
- Published by Wiley in Electroanalysis
- Vol. 30 (12) , 2841-2846
Simultaneous and Selective Imaging of Dopamine and Glutamate Using an Enzyme‐modified Large‐scale Integration (LSI)‐based Amperometric Electrochemical Device
Since neurotransmitters play critical roles in nervous systems, the imaging techniques that can visualize them are needed. This communication describes the development of a method for simultaneous imaging of dopamine (DA) and glutamate (Glu), typical neurotransmitters, using enzyme‐modified large‐scale integration (LSI)‐based amperometric devices, referred to “Bio‐LSI”. The DA was detected by using direct electrochemical oxidation while Glu was measured by using an indirect electrochemical reaction involving glutamate oxidase (GluOx)/horseradish peroxidase (HRP) and osmium (Os) polymer‐modified electrodes. The Os‐HRP polymer was modified on designated sensor electrodes through electrodeposition. The selective and simultaneous imaging of neurotransmitters such as DA and Glu was achieved by applying the enzyme‐modified Bio‐LSI.
- 2 September 2018
- Published by Wiley in Surface and Interface Analysis
- Vol. 51 (1) , 27-30
Scanning electrochemical cell microscopy for visualization and local electrochemical activities of lithium‐ion (de) intercalation process in lithium‐ion batteries electrodes
Scanning electrochemical cell microscopy with a single barrel micro‐/nano‐pipette (SECCM) was applied to lithium iron phosphate (LiFePO 4 ) composite positive electrodes and an isolated LiFePO 4 secondary particle for lithium‐ion batteries. To analyze lithium‐ion (Li + ) charge or discharge process on the electrodes using local probe, a pipette filled with LiCl electrolyte solution and Ag/AgCl quasi‐reference counter electrode (QRCE) was used. Both the local electrochemical activities of LiFePO 4 on the composite electrodes and a single particle were revealed by SECCM as in‐situ direct measurement of current response‐related Li + transport from mapping and cyclic voltammogram at confined area by the pipette. The mapping has visualized Li + deintercalation process from LiFePO 4 at +0.65 V (applied between the sample‐QRCE). We show that the SECCM system is a strong analytical tool for a characterization of local Li + behavior of active electrode materials in lithium‐ion batteries.
- 2 September 2018
- Published by Wiley in Surface and Interface Analysis
- Vol. 51 (1) , 27-30
Scanning electrochemical cell microscopy for visualization and local electrochemical activities of lithium‐ion (de) intercalation process in lithium‐ion batteries electrodes
Scanning electrochemical cell microscopy with a single barrel micro‐/nano‐pipette (SECCM) was applied to lithium iron phosphate (LiFePO 4 ) composite positive electrodes and an isolated LiFePO 4 secondary particle for lithium‐ion batteries. To analyze lithium‐ion (Li + ) charge or discharge process on the electrodes using local probe, a pipette filled with LiCl electrolyte solution and Ag/AgCl quasi‐reference counter electrode (QRCE) was used. Both the local electrochemical activities of LiFePO 4 on the composite electrodes and a single particle were revealed by SECCM as in‐situ direct measurement of current response‐related Li + transport from mapping and cyclic voltammogram at confined area by the pipette. The mapping has visualized Li + deintercalation process from LiFePO 4 at +0.65 V (applied between the sample‐QRCE). We show that the SECCM system is a strong analytical tool for a characterization of local Li + behavior of active electrode materials in lithium‐ion batteries.
- 20 August 2018
- Published by Wiley in ChemElectroChem
- Vol. 5 (20) , 3096-3101
Quantitative Real‐Time Monitoring of Antibody‐Induced Internalization of Epidermal Growth Factor Receptor on Single Living Mammalian Cells Using Scanning Electrochemical Microscopy
An antibody‐induced internalization of epidermal growth factor receptor (EGFR) was quantitatively monitored using scanning electrochemical microscopy (SECM) at the single‐cell level. The antibody Cetuximab is used for cancer treatment because of its capability to bind and internalize EGFR, which is one of the key membrane proteins associated with many cancers. To monitor antibody‐induced EGFR internalization, Cetuximab was simply labelled with enzymes and the resulting enzymatic products were then electrochemically detected by using a microelectrode. By optimizing experimental parameters, such as immunostaining condition, enzyme type, and buffer solution, we were able to successfully monitor the EGFR internalization by using SECM, from which we found a decrease in current responses from a single living cell by 20 % in the first 60 min, suggesting different internalization pathways from inherent ligand‐induced internalization.
- 20 August 2018
- Published by Wiley in ChemElectroChem
- Vol. 5 (20) , 3096-3101
Quantitative Real‐Time Monitoring of Antibody‐Induced Internalization of Epidermal Growth Factor Receptor on Single Living Mammalian Cells Using Scanning Electrochemical Microscopy
An antibody‐induced internalization of epidermal growth factor receptor (EGFR) was quantitatively monitored using scanning electrochemical microscopy (SECM) at the single‐cell level. The antibody Cetuximab is used for cancer treatment because of its capability to bind and internalize EGFR, which is one of the key membrane proteins associated with many cancers. To monitor antibody‐induced EGFR internalization, Cetuximab was simply labelled with enzymes and the resulting enzymatic products were then electrochemically detected by using a microelectrode. By optimizing experimental parameters, such as immunostaining condition, enzyme type, and buffer solution, we were able to successfully monitor the EGFR internalization by using SECM, from which we found a decrease in current responses from a single living cell by 20 % in the first 60 min, suggesting different internalization pathways from inherent ligand‐induced internalization.
- 10 July 2018
- Published by Wiley in ChemElectroChem
- Vol. 5 (16) , 2161
Simultaneous Multiplex Potentiostatic Electroanalysis with Liquid‐Junction‐Removed Reference Electrode System using a Closed Bipolar Electrode
The front cover artwork is provided by Prof. K. Y. Inoue, Prof. T. Matsue, and Mr. T. Iwama from Tohoku University, Sendai (Japan). The image shows an electrochemical measuring device with six sample cells and one reference cell. Simultaneous multiplex amperometry and voltammetry are available with integrated reference system without a liquid junction. Read the full text of the Communication at 10.1002/celc.201800536.
- 10 July 2018
- Published by Wiley in ChemElectroChem
- Vol. 5 (16) , 2161
Simultaneous Multiplex Potentiostatic Electroanalysis with Liquid‐Junction‐Removed Reference Electrode System using a Closed Bipolar Electrode
The front cover artwork is provided by Prof. K. Y. Inoue, Prof. T. Matsue, and Mr. T. Iwama from Tohoku University, Sendai (Japan). The image shows an electrochemical measuring device with six sample cells and one reference cell. Simultaneous multiplex amperometry and voltammetry are available with integrated reference system without a liquid junction. Read the full text of the Communication at 10.1002/celc.201800536.
- 5 July 2018
- Published by Oxford University Press (OUP) in Chemistry Letters
- Vol. 47 (7) , 843-845
Chemical Imaging Using a Closed Bipolar Electrode Array
In this study, we developed a new chemical imaging platform that uses a closed bipolar electrode (cBPE) array for electrochemiluminescence (ECL) detection. The cBPE array was successfully applied to use in the chemical imaging of molecular distributions by injection and a self-induced redox cycling. The results show the possibility of high-resolution chemical imaging using a cBPE array.
- 5 July 2018
- Published by Oxford University Press (OUP) in Chemistry Letters
- Vol. 47 (7) , 843-845
Chemical Imaging Using a Closed Bipolar Electrode Array
In this study, we developed a new chemical imaging platform that uses a closed bipolar electrode (cBPE) array for electrochemiluminescence (ECL) detection. The cBPE array was successfully applied to use in the chemical imaging of molecular distributions by injection and a self-induced redox cycling. The results show the possibility of high-resolution chemical imaging using a cBPE array.
- 5 February 2018
- Published by Oxford University Press (OUP) in Chemistry Letters
- Vol. 47 (2) , 204-206
Micropatterning of Nafion Membranes on an Electrode Array Using Photolithographic and Lift-off Techniques for Selective Electrochemical Detection and Signal Accumulation
Herein, we present the fabrication of micropatterned Nafion membranes on an electrode array using a combination of photolithographic and lift-off techniques. The Nafion-modified electrodes were applied for selective assays based on the charges of redox compounds. In addition, redox compounds with positive charges were successfully accumulated on the Nafion layers, so that redox signals were improved with the anodic stripping. To the best of our knowledge, this is the first report on micropatterning of Nafion membranes using photolithographic and lift-off techniques.
- 5 February 2018
- Published by Oxford University Press (OUP) in Chemistry Letters
- Vol. 47 (2) , 204-206
Micropatterning of Nafion Membranes on an Electrode Array Using Photolithographic and Lift-off Techniques for Selective Electrochemical Detection and Signal Accumulation
Herein, we present the fabrication of micropatterned Nafion membranes on an electrode array using a combination of photolithographic and lift-off techniques. The Nafion-modified electrodes were applied for selective assays based on the charges of redox compounds. In addition, redox compounds with positive charges were successfully accumulated on the Nafion layers, so that redox signals were improved with the anodic stripping. To the best of our knowledge, this is the first report on micropatterning of Nafion membranes using photolithographic and lift-off techniques.
- Open Access
- 14 November 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (23) , 12778-12786
Electrochemicolor Imaging Using an LSI-Based Device for Multiplexed Cell Assays
Multiplexed bioimaging systems have triggered the development of effective assays, contributing new biological information. Although electrochemical imaging is beneficial for quantitative analysis in real time, monitoring multiple cell functions is difficult. We have developed a novel electrochemical imaging system, herein, using a large-scale integration (LSI)-based amperometric device for detecting multiple biomolecules simultaneously. This system is designated as an electrochemicolor imaging system in which the current signals from two different types of biomolecules are depicted as a multicolor electrochemical image. The mode-selectable function of the 400-electrode device enables the imaging system and two different potentials can be independently applied to the selected electrodes. The imaging system is successfully applied for detecting multiple cell functions of the embryonic stem (ES) cell and the rat pheochromocytoma (PC12) cell aggregates. To the best of our knowledge, this is the first time that a real-time electrochemical mapping technique for multiple electroactive species, simultaneously, has been reported. The imaging system is a promising bioanalytical method for exploring complex biological phenomena.
- 14 November 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (23) , 12778-12786
Open AccessElectrochemicolor Imaging Using an LSI-Based Device for Multiplexed Cell Assays
Multiplexed bioimaging systems have triggered the development of effective assays, contributing new biological information. Although electrochemical imaging is beneficial for quantitative analysis in real time, monitoring multiple cell functions is difficult. We have developed a novel electrochemical imaging system, herein, using a large-scale integration (LSI)-based amperometric device for detecting multiple biomolecules simultaneously. This system is designated as an electrochemicolor imaging system in which the current signals from two different types of biomolecules are depicted as a multicolor electrochemical image. The mode-selectable function of the 400-electrode device enables the imaging system and two different potentials can be independently applied to the selected electrodes. The imaging system is successfully applied for detecting multiple cell functions of the embryonic stem (ES) cell and the rat pheochromocytoma (PC12) cell aggregates. To the best of our knowledge, this is the first time that a real-time electrochemical mapping technique for multiple electroactive species, simultaneously, has been reported. The imaging system is a promising bioanalytical method for exploring complex biological phenomena.
- Open Access
- 26 October 2017
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 142 (23) , 4343-4354
Micro/nanoelectrochemical probe and chip devices for evaluation of three-dimensional cultured cells
Herein, we present an overview of recent research progress in the development of micro/nanoelectrochemical probe and chip devices for the evaluation of three-dimensional (3D) cultured cells. First, we discuss probe devices: a general outline, evaluation of O2 consumption, enzyme-modified electrodes, evaluation of endogenous enzyme activity, and the collection of cell components from cell aggregates are discussed. The next section is focused on integrated chip devices: a general outline, electrode array devices, smart electrode array devices, droplet detection of 3D cultured cells, cell manipulation using dielectrophoresis (DEP), and electrodeposited hydrogels used for fabrication of 3D cultured cells on chip devices are discussed. Finally, we provide a summary and discussion of future directions of research in this field.
- 26 October 2017
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 142 (23) , 4343-4354
Open AccessMicro/nanoelectrochemical probe and chip devices for evaluation of three-dimensional cultured cells
Herein, we present an overview of recent research progress in the development of micro/nanoelectrochemical probe and chip devices for the evaluation of three-dimensional (3D) cultured cells. First, we discuss probe devices: a general outline, evaluation of O2 consumption, enzyme-modified electrodes, evaluation of endogenous enzyme activity, and the collection of cell components from cell aggregates are discussed. The next section is focused on integrated chip devices: a general outline, electrode array devices, smart electrode array devices, droplet detection of 3D cultured cells, cell manipulation using dielectrophoresis (DEP), and electrodeposited hydrogels used for fabrication of 3D cultured cells on chip devices are discussed. Finally, we provide a summary and discussion of future directions of research in this field.