Tomoyuki Yasukawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tomoyuki Yasukawa has a total of 221 co-authors. Here are the top co-authors by number of shared publications:
Tomokazu Matsue
Tohoku Univ, Head Off Enterprise Partnerships, 468-1 Aoba, Sendai, Miyagi 9808545, Japan
73 shared publicationsHitoshi Shiku
Graduate School of Environmental Studies, Tohoku University, 6-6-11, Aramaki, Aoba, Sendai, Miyagi 980-8579, Japan
60 shared publicationsFumio Mizutani
Graduate School of Material Sciences, University of Hyogo, Japan
49 shared publications- Masato Suzuki
Graduate School of Science, University of Hyogo, 3-2-1, Kouto, Kamigori-cho, Ako-gun, Hyogo, Japan
26 shared publications - Tomokazu Matsue
Graduate School of Environmental Studies, Tohoku University, 6-6-11-604 Aramaki-aza Aoba, Aoba-ku, Sendai, Miyagi 980-8579, Japan
14 shared publications Kuniaki Nagamine
Graduate School of Environmental Studies, Tohoku University
13 shared publications
Latest Publications
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
Selective dielectrophoretic array formation of unmodified B cells through microparticle modification of non-target cells
Unmodified B cells were preferentially trapped in microwells by p -DEP, whereas cell–bead complexes showed reduced stable trapping, enabling B-cell-enriched arrays with ∼70% microwell occupancy within 10 min.
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
Selective dielectrophoretic array formation of unmodified B cells through microparticle modification of non-target cells
Unmodified B cells were preferentially trapped in microwells by p -DEP, whereas cell–bead complexes showed reduced stable trapping, enabling B-cell-enriched arrays with ∼70% microwell occupancy within 10 min.
- Open Access
- 18 September 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (9) , 6512-6520
A Microfluidic Platform Integrating Dielectrophoretic Concentration and Impedimetric Sensing for Rapid Salmonella choleraesuis Detection
Fast and sensitive detection of foodborne bacteria, such as Salmonella, is essential for food safety and public health control. This study constructed a microfluidic device integrating a top-bottom opposite electrode pair for performing positive dielectrophoresis (pDEP) and electrochemical impedance spectroscopy (EIS). The immunomagnetic beads (IMBs) modified with anti-Salmonella antibodies were spiked in Salmonella enterica serovar Choleraesuis (SC)-containing samples for 30 min to form IMBs@SC complexes, and they were separated by a magnet, which can prevent the sample matrix from contaminating the EIS detectors. After applying the 50 kHz/7.5 Vpp pDEP for 3 min to collect the IMBs@SC complexes in the microholes of the working electrodes, EIS was used to determine the SC concentration. The linear range and the calculated detection limit obtained from SC-spiked undiluted milk samples are 101 to 104 and 2 cfu/mL. The total procedures from the IMBs immunoreaction to the sample-to-result on the device only take 50 min. The microfluidic device offers a promising platform for the rapid and ultrasensitive detection of pathogenic bacteria.
- 18 September 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (9) , 6512-6520
Open AccessA Microfluidic Platform Integrating Dielectrophoretic Concentration and Impedimetric Sensing for Rapid Salmonella choleraesuis Detection
Fast and sensitive detection of foodborne bacteria, such as Salmonella, is essential for food safety and public health control. This study constructed a microfluidic device integrating a top-bottom opposite electrode pair for performing positive dielectrophoresis (pDEP) and electrochemical impedance spectroscopy (EIS). The immunomagnetic beads (IMBs) modified with anti-Salmonella antibodies were spiked in Salmonella enterica serovar Choleraesuis (SC)-containing samples for 30 min to form IMBs@SC complexes, and they were separated by a magnet, which can prevent the sample matrix from contaminating the EIS detectors. After applying the 50 kHz/7.5 Vpp pDEP for 3 min to collect the IMBs@SC complexes in the microholes of the working electrodes, EIS was used to determine the SC concentration. The linear range and the calculated detection limit obtained from SC-spiked undiluted milk samples are 101 to 104 and 2 cfu/mL. The total procedures from the IMBs immunoreaction to the sample-to-result on the device only take 50 min. The microfluidic device offers a promising platform for the rapid and ultrasensitive detection of pathogenic bacteria.
- 30 January 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (5) , 975-981
Rapid assessment of the gate function and membrane properties of connexin-embedded giant plasma membrane vesicles in a microwell array
Giant plasma membrane vesicles (GPMVs) incorporating connexin proteins, referred to as connectosomes, serve as promising tools for studying cell membrane properties and intercellular communication. This study aimed to evaluate the membrane capacitance of connectosomes derived from HeLa cells and establish a method for assessing the gate function of connexin hemichannels. We investigated the behavior of dielectrophoresis (DEP) manipulation of connectosomes and HeLa cells by using microwell array electrodes. The frequency dependence of DEP force for connectosomes and HeLa cells suggested a low membrane capacitance of the connectosomes compared to that of HeLa cells. Positive DEP (p-DEP) was used to trap the connectosomes in the microwell array, where a relatively strong electric field was formed. This approach facilitated monitoring of the fluorescence intensity of individual connectosomes immediately after the solutions were exchanged, enhancing our ability to assess the release dynamics of fluorescent molecules and the hemichannel's open/closed states. The results confirmed that connexin hemichannels were regulated by the exterior concentration of Ca2+, allowing selective control over drug storage and release. The method developed in this study elucidates the functional properties of connectosomes and would provide a valuable platform for future applications in targeted drug delivery systems.
- 30 January 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (5) , 975-981
Rapid assessment of the gate function and membrane properties of connexin-embedded giant plasma membrane vesicles in a microwell array
Giant plasma membrane vesicles (GPMVs) incorporating connexin proteins, referred to as connectosomes, serve as promising tools for studying cell membrane properties and intercellular communication. This study aimed to evaluate the membrane capacitance of connectosomes derived from HeLa cells and establish a method for assessing the gate function of connexin hemichannels. We investigated the behavior of dielectrophoresis (DEP) manipulation of connectosomes and HeLa cells by using microwell array electrodes. The frequency dependence of DEP force for connectosomes and HeLa cells suggested a low membrane capacitance of the connectosomes compared to that of HeLa cells. Positive DEP (p-DEP) was used to trap the connectosomes in the microwell array, where a relatively strong electric field was formed. This approach facilitated monitoring of the fluorescence intensity of individual connectosomes immediately after the solutions were exchanged, enhancing our ability to assess the release dynamics of fluorescent molecules and the hemichannel's open/closed states. The results confirmed that connexin hemichannels were regulated by the exterior concentration of Ca2+, allowing selective control over drug storage and release. The method developed in this study elucidates the functional properties of connectosomes and would provide a valuable platform for future applications in targeted drug delivery systems.
- Open Access
- 25 October 2023
- Published by MYU K.K. in Sensors and Materials
- Vol. 35 (10) , 4781-4788
Effect of Valinomycin on the Respiration Activity of Zebrafish Embryos Using a Large-Scale-Integration-based Multiple Amperometric Biosensor
- 25 October 2023
- Published by MYU K.K. in Sensors and Materials
- Vol. 35 (10) , 4781-4788
Open AccessEffect of Valinomycin on the Respiration Activity of Zebrafish Embryos Using a Large-Scale-Integration-based Multiple Amperometric Biosensor
- Open Access
- 12 July 2023
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 13 (31) , 21118-21126
Dielectrophoretic trapping of nanosized biomolecules on plasmonic nanohole arrays for biosensor applications: simple fabrication and visible-region detection
In this study, we experimentally demonstrated a simple, label-free, rapid, cost-effective biomolecules' trapping in visible region with combination developed gold nanohole arrays and dielectrophoresis.
- 12 July 2023
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 13 (31) , 21118-21126
Open AccessDielectrophoretic trapping of nanosized biomolecules on plasmonic nanohole arrays for biosensor applications: simple fabrication and visible-region detection
In this study, we experimentally demonstrated a simple, label-free, rapid, cost-effective biomolecules' trapping in visible region with combination developed gold nanohole arrays and dielectrophoresis.
- Open Access
- 5 March 2023
- Published by The Electrochemical Society of Japan in Denki Kagaku
- Vol. 91 (1) , 56-61
Stripping Voltammetry with the Conversion of Signal Molecules and Its Application to Bioanalysis
- 5 March 2023
- Published by The Electrochemical Society of Japan in Denki Kagaku
- Vol. 91 (1) , 56-61
Open AccessStripping Voltammetry with the Conversion of Signal Molecules and Its Application to Bioanalysis
- 7 November 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (4) , 692-701
Development of a simultaneous electrorotation device with microwells for monitoring the rotation rates of multiple single cells upon chemical stimulation
Here, we described a unique simultaneous electrorotation (ROT) device for monitoring the rotation rate of Jurkat cells via chemical stimulation without fluorescent labeling and an algorithm for estimating cell rotation rates. The device comprised two pairs of interdigitated array electrodes that were stacked orthogonally through a 20 μm-thick insulating layer with rectangular microwells. Four microelectrodes (two were patterned on the bottom of the microwells and the other two on the insulating layer) were arranged on each side of the rectangular microwells. The cells, which were trapped in the microwells, underwent ROT when AC voltages were applied to the four microelectrodes to generate a rotating electric field. These microwells maintained the cells even in fluid flows. Thereafter, the ROT rates of the trapped cells were estimated and monitored during the stimulation. We demonstrated the feasibility of estimating the chemical efficiency of cells by monitoring the ROT rates of the cells. After introducing a Jurkat cell suspension into the device, the cells were subjected to ROT by applying an AC signal. Further, the rotating cells were chemically stimulated by adding an ionomycin (a calcium ionophore)-containing aliquot. The ROT rate of the ionomycin-stimulated cells decreased gradually to 90% of the initial rate after 30 s. The ROT rate was reduced by an increase in membrane capacitance. Thus, our device enabled the simultaneous chemical stimulation-induced monitoring of the alterations in the membrane capacitances of many cells without fluorescent labeling.
- 7 November 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (4) , 692-701
Development of a simultaneous electrorotation device with microwells for monitoring the rotation rates of multiple single cells upon chemical stimulation
Here, we described a unique simultaneous electrorotation (ROT) device for monitoring the rotation rate of Jurkat cells via chemical stimulation without fluorescent labeling and an algorithm for estimating cell rotation rates. The device comprised two pairs of interdigitated array electrodes that were stacked orthogonally through a 20 μm-thick insulating layer with rectangular microwells. Four microelectrodes (two were patterned on the bottom of the microwells and the other two on the insulating layer) were arranged on each side of the rectangular microwells. The cells, which were trapped in the microwells, underwent ROT when AC voltages were applied to the four microelectrodes to generate a rotating electric field. These microwells maintained the cells even in fluid flows. Thereafter, the ROT rates of the trapped cells were estimated and monitored during the stimulation. We demonstrated the feasibility of estimating the chemical efficiency of cells by monitoring the ROT rates of the cells. After introducing a Jurkat cell suspension into the device, the cells were subjected to ROT by applying an AC signal. Further, the rotating cells were chemically stimulated by adding an ionomycin (a calcium ionophore)-containing aliquot. The ROT rate of the ionomycin-stimulated cells decreased gradually to 90% of the initial rate after 30 s. The ROT rate was reduced by an increase in membrane capacitance. Thus, our device enabled the simultaneous chemical stimulation-induced monitoring of the alterations in the membrane capacitances of many cells without fluorescent labeling.
- 5 April 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 209, 114250
Selective retrieval of antibody-secreting hybridomas in cell arrays based on the dielectrophoresis
- 5 April 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 209, 114250
Selective retrieval of antibody-secreting hybridomas in cell arrays based on the dielectrophoresis
- 1 February 2022
- Published by Springer Nature in Analytical Sciences
- Vol. 38 (2) , 235-239
Electrofusion of cells with different diameters by generating asymmetrical electric field in the microwell array
This paper reports a superiority of the asymmetric electric field formed in the rectangle microwell array for the electrofusion of splenocytes and myeloma cells with different diameters. The upper substrate with microband electrodes was mounted on the lower substrate with the microwell array. Two electrodes were arranged at the both sides of the microwells on the bottom surface. An attractive force of positive dielectrophoresis was employed to capture splenocytes with smaller diameter and myeloma cells with larger diameter at the right and left of microwells by applying AC electric field. The splenocytes and myeloma cells were fused by the asymmetric electric field that was generated in the microwells by applying DC electric pulse to the bottom electrode at the right side. The asymmetric field could allow to the formation of small openings on the membrane for the fusion of smaller splenocytes by experiencing higher field and the suppression for the disruption of larger myeloma cells by experiencing lower field. Graphical abstract
- 1 February 2022
- Published by Springer Nature in Analytical Sciences
- Vol. 38 (2) , 235-239
Electrofusion of cells with different diameters by generating asymmetrical electric field in the microwell array
This paper reports a superiority of the asymmetric electric field formed in the rectangle microwell array for the electrofusion of splenocytes and myeloma cells with different diameters. The upper substrate with microband electrodes was mounted on the lower substrate with the microwell array. Two electrodes were arranged at the both sides of the microwells on the bottom surface. An attractive force of positive dielectrophoresis was employed to capture splenocytes with smaller diameter and myeloma cells with larger diameter at the right and left of microwells by applying AC electric field. The splenocytes and myeloma cells were fused by the asymmetric electric field that was generated in the microwells by applying DC electric pulse to the bottom electrode at the right side. The asymmetric field could allow to the formation of small openings on the membrane for the fusion of smaller splenocytes by experiencing higher field and the suppression for the disruption of larger myeloma cells by experiencing lower field. Graphical abstract