  • Exergy Analysis of Data Center Thermal Management Systems

    by Amip J. Shah, Van P. Carey, Cullen E. Bash, Chandrakant D. Patel, Ratnesh K. Sharma


  • Evaluating Life-Cycle Environmental Impact of Data Centers

    by Amip Shah, Cullen Bash, Ratnesh Sharma, Tom Christian, Brian J. Watson, Chandrakant Patel

    Numerous evaluation metrics and standards are being proposed across industry and government to measure and monitor the energy efficiency of data centers. However, the energy use of data centers is just one aspect of the environmental impact. In this paper, we explore the overall environmental footprint of data centers beyond just energy efficiency. Building upon established procedures from the environmental sciences, we create an end-to-end life-cycle model of the environmental footprint of data centers across a diverse range of impacts. We test this model in the case study of a hypothetical 2.2-MW data center. Our analysis suggests the need for evaluation metrics that go beyond just operational energy use in order to achieve sustainable data centers.


  • Exergo-Thermo-Volumes: An Approach for Environmentally Sustainable Thermal Management of Energy Conversion Devices

    by Amip J. Shah, Chandrakant D. Patel

    The design of cooling solutions is an important consideration for the efficient management of different types of energy technologies. In the present work, we adapt the method of thermo-volumes—which has been used for nearly a decade in the design of electronic cooling solutions—for purposes of expeditiously understanding the thermal resistance of a given solution (in terms of cooling performance) along with its flow resistance (an indicator of the pumping power or energy consumption, which will be required by the thermal solution). Furthermore, we expand on thermo-volumes by including the lifetime exergy cost as a means to enable the consideration of resource consumption (and thus the environmental sustainability) of the cooling solution. We apply this framework for evaluation of thermal management solutions in terms of the heat removal capacity per unit lifetime exergy consumption. This paper concludes by illustrating applicability of the method to the design of a fuel cell thermal management solution.


  • Thermal Management Considerations for Geographically Distributed Computing Infrastructures

    by Amip Shah, Cullen Bash, Martin Arlitt, Yuan Chen, Daniel Gmach, Ratnesh Sharma, Chandrakant Patel

    This paper discusses an approach for optimizing the infrastructure thermal performance related to a geographically distributed computing service. Beginning by modeling the total energy costs associated with cooling a distributed environment, the cooling efficiency of a service is evaluated by superposing the piecewise IT workloads that may be delivered from various locations. We find that the total service-level thermal performance can be distinct from the facility- or infrastructure-level thermal performance, which requires a different global thermal management strategy relative to that of single-site environments. The approach is illustrated for a hypothetical example wherein a service is delivered from three different data centers in geographically diverse locations. Depending on the workload characteristics, the optimal distribution of resources across the data centers varies; but through dynamic resource allocation, it becomes possible to support the same service at increased energy efficiencies.


  • Designing Environmentally Sustainable Computer Systems Using Networks of Exergo-Thermo-Volume Building Blocks

    by Amip Shah, Chandrakant D. Patel, Cullen Bash

    As regulation and competition drives the creation of environmentally sustainable systems, cradle-to-cradle life-cycle assessment (LCA) methodologies are becoming increasingly commonplace. However, existing LCA techniques are often laborious and costly to implement. Moreover, while LCA provides great insight into the impact of a given product or service, the translation of LCA outputs into iterative design inputs is not straightforward. A tighter linkage between product design and LCA methods is desired. In this paper, we propose creating such a linkage through the method of “exergo-thermo-volumes”. Specifically, we consider the design of an enterprise server with multiple heat dissipating components. Each of these heat dissipating components can be represented as an exergo-thermo-volume (ETV). Simultaneously, the cooling solution that removes heat from each of these components is also treated as an ETV. We show that the optimal system design can be determined through superposition of each of these ETVs with appropriately coupled boundary conditions. The resulting ETV representation of discretized heat sources and companioned cooling solutions essentially leads to the creation of an ETV network, which can then be optimized for the minimum sustainability footprint. We find that the optimal solution predicted by the exergo-thermo-volume approach matches those that would be predicted intuitively based on general design-for-environment and thermal management practices, but — using the current approach — we are also able to quantitatively show the difference between the optimal and sub-optimal choices. We conclude by demonstrating the applicability of the exergo-thermo-volume approach for the sustainable design of an enterprise server.


  • Thermodynamics-Based Object-Oriented Environmental Design of an Industrial Air Conditioner

    by Amip Shah, Wilfredo Lugo, Chandrakant Patel

    Continued efforts to reduce the environmental impact of products and services are leading to the increased prevalence of life-cycle assessment (LCA) during the design phase. A key challenge in traditional process-based LCA is the validation of vast life-cycle inventory data, which easily numbers in the tens of thousands of data points. In this paper, we utilize an ‘object-based’ approach from software engineering to manage the large amount of data and combine this approach with simple thermodynamic principles, thus significantly reducing the chance of error in LCA inputs. The approach is demonstrated for the test case of a typical industrial air-conditioning unit. We find that implementation of the object-based approach identifies numerous potential errors in the life-cycle inventory data. Thus, the proposed approach enables the designer to perform a more robust environmental analysis of a given system. This facilitates a better identification and prioritization of opportunities for reducing the environmental footprint across the system life-cycle.


  • Wiresweep Reduction via Direct Cavity Injection During Encapsulation of Stacked Chip-Scale Packages

    by Jason M. Brand, Salvatore A. Ruggero, Amip J. Shah

    As packaging continues to offer challenges with variable stacked die configurations of increasing complexity, traditional transfer mold encapsulation faces challenges in defining a robust process window. A major concern is the problem of “wiresweep,” wherein deformation of the wirebond during the mold process can potentially cause shortcircuiting. Several prior studies have focused on qualifying the effects of various wirebond and mold process parameters on package wiresweep, but most of these studies are restricted to single (discrete) die packages. This paper attempts to fill this gap of knowledge by experimenting with a variety of test vehicles with different stacking configurations. Specifically, the effects of varying loop height, stack height, and mold compound type are quantified in terms of maximum wiresweep. We find that loop height can have a considerable effect on wiresweep, with the maximum wiresweep being reduced by half (from around 6% to less than 3%) simply by reducing the loop height. Additionally, the study finds that for a given mold process, higher die stacks tend to increase wiresweep, although a threshold stack height exists beyond which further stacking can reduce wiresweep. Lastly, the data suggest that the choice of mold compound can adversely impact wiresweep, especially for test vehicles with traditionally high wiresweep. Having identified these trends, semianalytical models from the literature are used to investigate the cause behind these observations. The analysis suggests that the mold front velocity has the major root impact on package wiresweep. To validate this hypothesis, the series of tests conducted earlier is repeated for a compression mold process, which provides greater control over the mold front velocity. As predicted by the model, significant reduction in wiresweep is achieved. Thus, the compression mold process seems to offer the opportunity for reducing wiresweep without any compromise in the complexity of the die stack.


  • Optimization of Thermoelectric Modules for Computer System Thermal Management and Infrastructure Energy Efficiency

    by Amip J. Shah, Anita Rogacs, Chandrakant D. Patel

    With the proliferation of multiple cores on a single processor and the integration of numerous stacked die in chip packages, the resulting non-uniformity in power dissipation necessitates spatially and temporally localized control of temperature in the package. Thermoelectric (TE) devices can potentially provide one mechanism to achieve such control. Unfortunately, at typical junction-to-ambient temperatures, the coefficient-of-performance (COP) of existing bulk TE devices tends to be quite low. As a result, for many high-power systems, the additional power input required to operate a TE cooling module can lead to an increase in the overall system cost-of-ownership, causing TE cooling solutions to be excluded from cost-sensitive thermal management solutions in high-volume computer systems. However, recent trends of compaction and consolidation of computer servers in high-density data centers have resulted in a dramatic increase in the burdened cost-of-ownership of mission-critical IT facilities. For example, the energy consumption of the cooling infrastructure for many high-density data centers can equal or exceed the power consumption of the compute equipment. Thus, for the growing enterprise thermal management segment, the appropriate metric is no longer the COP of the thermal solution but rather the COP of the cooling ensemble, which takes into account the energy efficiency of cooling solutions in the chip, system, rack, data center and facility. To examine the effects of chip-level COP on the ensemble-level COP, this paper explores a case study comparing two ensemble solutions. In one case, local hotspots on a chip in a three-dimensional package are mitigated by increasing fan power at the system level (and subsequently, in the computer room and the rest of the ensemble). In another case, local hotspots at the chip are mitigated through spot-cooling via TE cooling modules. For each of these cases, the COP of the ensemble is evaluated. The model suggests that while feasible, the benefit of using TEs at current performance levels is limited. However, ongoing research that may improve TE performance in the future has the potential to enhance infrastructure energy efficiency.

  • Designing Environmentally Sustainable Electronic Cooling Systems Using Exergo-Thermo-Volumes

    by Amip J. Shah, Chandrakant D. Patel

    Thermo-volumes allow the design engineer to expediently understand the thermal resistance of a given cooling solution (an indicator of performance) along with its flow resistance (an indicator of the pumping power, or energy consumption, which will be required by the fluid handler). In the present work, we expand upon thermo-volumes by including the lifetime exergy cost (in units of Joules of availability destroyed) as a means to enable the consideration of resource consumption (and thus the environmental sustainability) of the cooling solution. To achieve these exergo-thermo-volumes, we reinterpret previous definitions of thermo-volumes in terms of the entropy generated during heat transfer and fluid flow. The Guoy-Stodola theorem is used to convert this entropy generation into an ‘operational’ exergy loss. Next, based on the material choice and assembly processes used in creating the product, an embedded exergy consumption that accounts for the amount of exergy destroyed during extraction, transportation and disposal of the material is attached to the operational exergy loss. Thus, the total ‘cradle-to-cradle’ exergy loss of the solution is devised. In this framework, the optimal solution will be that which destroys the minimal amount of exergy. Correspondingly, instead of relying upon the COP (which is focused on operational consumption), we propose evaluation of cooling solutions in terms of the heat removal capacity per unit lifetime exergy consumption. The paper concludes by illustrating applicability of the method to the design of an enterprise server. It should be noted that although the paper is focused on electronics cooling solutions, the methodology is designed to be sufficiently general for use in any thermal management application.