Chandrakant D. Patel
Chandrakant D. Patel has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Cullen Bash
Hewlett Packard Laboratories, Palo Alto, CA
4 shared publications - Van P. Carey
Mechanical Engineering Department, University of California, Berkeley, CA 94720-1740
3 shared publications - Amip J. Shah
Hewlett Packard Laboratories, Palo Alto, CA
2 shared publications - Amip J. Shah
Department of Mechanical Engineering, University of California, Berkeley, CA 94720-1740
1 shared publication - Amip J. Shah
Department of Mechanical Engineering, University of California, Berkeley, CA 94720-1740
1 shared publication - Anita Rogacs1 shared publication
Latest Publications
- Open Access
Microprocessor Optimizations for the Internet of Things: A Survey
The Internet of Things (IoT) refers to a pervasive presence of interconnected and uniquely identifiable physical devices. These devices' goal is to gather data and drive actions in order to improve productivity, and ultimately reduce or eliminate reliance on human intervention for data acquisition, interpretation, and use. The proliferation of these connected low-power devices will result in a data explosion that will significantly increase data transmission costs with respect to energy consumption and latency. Edge computing reduces these costs by performing computations at the edge nodes, prior to data transmission, to interpret and/or utilize the data. While much research has focused on the IoT's connected nature and communication challenges, the challenges of IoT embedded computing with respect to device microprocessors has received much less attention. This paper explores IoT applications' execution characteristics from a microarchitectural perspective and the microarchitectural characteristics that will enable efficient and effective edge computing. To tractably represent a wide variety of next-generation IoT applications, we present a broad IoT application classification methodology based on application functions, to enable quicker workload characterizations for IoT microprocessors. We then survey and discuss potential microarchitectural optimizations and computing paradigms that will enable the design of right-provisioned microprocessors that are efficient, configurable, extensible, and scalable. This paper provides a foundation for the analysis and design of a diverse set of microprocessor architectures for next-generation IoT devices.
Open AccessMicroprocessor Optimizations for the Internet of Things: A Survey
The Internet of Things (IoT) refers to a pervasive presence of interconnected and uniquely identifiable physical devices. These devices' goal is to gather data and drive actions in order to improve productivity, and ultimately reduce or eliminate reliance on human intervention for data acquisition, interpretation, and use. The proliferation of these connected low-power devices will result in a data explosion that will significantly increase data transmission costs with respect to energy consumption and latency. Edge computing reduces these costs by performing computations at the edge nodes, prior to data transmission, to interpret and/or utilize the data. While much research has focused on the IoT's connected nature and communication challenges, the challenges of IoT embedded computing with respect to device microprocessors has received much less attention. This paper explores IoT applications' execution characteristics from a microarchitectural perspective and the microarchitectural characteristics that will enable efficient and effective edge computing. To tractably represent a wide variety of next-generation IoT applications, we present a broad IoT application classification methodology based on application functions, to enable quicker workload characterizations for IoT microprocessors. We then survey and discuss potential microarchitectural optimizations and computing paradigms that will enable the design of right-provisioned microprocessors that are efficient, configurable, extensible, and scalable. This paper provides a foundation for the analysis and design of a diverse set of microprocessor architectures for next-generation IoT devices.
- 15 February 2012
- Published by Springer Nature
- p. 383-446
Exergy Analysis of Data Center Thermal Management Systems
- 15 February 2012
- Published by Springer Nature
- p. 383-446
Exergy Analysis of Data Center Thermal Management Systems
- 17 May 2010
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 132 (2) , 021002
Exergo-Thermo-Volumes: An Approach for Environmentally Sustainable Thermal Management of Energy Conversion Devices
The design of cooling solutions is an important consideration for the efficient management of different types of energy technologies. In the present work, we adapt the method of thermo-volumes—which has been used for nearly a decade in the design of electronic cooling solutions—for purposes of expeditiously understanding the thermal resistance of a given solution (in terms of cooling performance) along with its flow resistance (an indicator of the pumping power or energy consumption, which will be required by the thermal solution). Furthermore, we expand on thermo-volumes by including the lifetime exergy cost as a means to enable the consideration of resource consumption (and thus the environmental sustainability) of the cooling solution. We apply this framework for evaluation of thermal management solutions in terms of the heat removal capacity per unit lifetime exergy consumption. This paper concludes by illustrating applicability of the method to the design of a fuel cell thermal management solution.
- 17 May 2010
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 132 (2) , 021002
Exergo-Thermo-Volumes: An Approach for Environmentally Sustainable Thermal Management of Energy Conversion Devices
The design of cooling solutions is an important consideration for the efficient management of different types of energy technologies. In the present work, we adapt the method of thermo-volumes—which has been used for nearly a decade in the design of electronic cooling solutions—for purposes of expeditiously understanding the thermal resistance of a given solution (in terms of cooling performance) along with its flow resistance (an indicator of the pumping power or energy consumption, which will be required by the thermal solution). Furthermore, we expand on thermo-volumes by including the lifetime exergy cost as a means to enable the consideration of resource consumption (and thus the environmental sustainability) of the cooling solution. We apply this framework for evaluation of thermal management solutions in terms of the heat removal capacity per unit lifetime exergy consumption. This paper concludes by illustrating applicability of the method to the design of a fuel cell thermal management solution.
- 1 February 2008
- Published by Wiley in Journal of Heat Transfer
- Vol. 130 (2) , 021401
Exergy Analysis of Data Center Thermal Management Systems
The modeling of recirculation patterns in air-cooled data centers is of interest to ensure adequate thermal management of computer racks at increased heat densities. Most metrics that describe recirculation are based exclusively on temperature inside the data center, and therefore fail to provide adequate information regarding the energy efficiency of the thermal infrastructure. This paper addresses this limitation through an exergy analysis of the data center thermal management system. The approach recognizes that the mixing of hot and cold streams in the data center airspace is an irreversible process and must therefore lead to a loss of exergy. Experimental validation in a test data center confirms that such an exergy-based characterization in the cold aisle reflects the same recirculation trends as suggested by traditional temperature-based metrics. Further, by extending the exergy-based model to include irreversibilities from other components of the thermal architecture, it becomes possible to quantify the amount of available energy supplied to the cooling system that is being utilized for thermal management purposes. The energy efficiency of the entire data center cooling system can then be collapsed into the single metric of net exergy loss. When evaluated against a ground state of the external ambience, this metric enables an estimate of how much of the energy emitted into the environment could potentially be harnessed in the form of useful work. Thus, this paper successfully demonstrates that the proposed exergy-based approach can provide a foundation upon which the data center cooling system can be simultaneously evaluated for thermal manageability and energy efficiency.
- 1 February 2008
- Published by Wiley in Journal of Heat Transfer
- Vol. 130 (2) , 021401
Exergy Analysis of Data Center Thermal Management Systems
The modeling of recirculation patterns in air-cooled data centers is of interest to ensure adequate thermal management of computer racks at increased heat densities. Most metrics that describe recirculation are based exclusively on temperature inside the data center, and therefore fail to provide adequate information regarding the energy efficiency of the thermal infrastructure. This paper addresses this limitation through an exergy analysis of the data center thermal management system. The approach recognizes that the mixing of hot and cold streams in the data center airspace is an irreversible process and must therefore lead to a loss of exergy. Experimental validation in a test data center confirms that such an exergy-based characterization in the cold aisle reflects the same recirculation trends as suggested by traditional temperature-based metrics. Further, by extending the exergy-based model to include irreversibilities from other components of the thermal architecture, it becomes possible to quantify the amount of available energy supplied to the cooling system that is being utilized for thermal management purposes. The energy efficiency of the entire data center cooling system can then be collapsed into the single metric of net exergy loss. When evaluated against a ground state of the external ambience, this metric enables an estimate of how much of the energy emitted into the environment could potentially be harnessed in the form of useful work. Thus, this paper successfully demonstrates that the proposed exergy-based approach can provide a foundation upon which the data center cooling system can be simultaneously evaluated for thermal manageability and energy efficiency.
- 1 December 2005
- Published by ASME International in Journal of Electronic Packaging
- Vol. 128 (4) , 360-369
An Exergy-Based Figure-of-Merit for Electronic Packages
Chip power consumption and heat dissipation have become important design issues because of increased energy costs and thermal management limitations. As a global compute utility evolves, seamless connectivity from the chip to the data center will become increasingly important. The optimization of such an infrastructure will require performance metrics that can adequately capture the thermodynamic and compute behavior at multiple physical length scales. In this paper, an exergy-based figure-of-merit (FoM), defined as the ratio of computing performance (in MIPS) to the thermodynamic performance (in exergy loss), is proposed for the evaluation of computational performance. The paper presents the framework to apply this metric at the chip level. Formulations for the exergy loss in simple air-cooled heat sink packages are developed, and application of the proposed approach is illustrated through two examples. The first comparatively assesses the loss in performance resulting from different cooling solutions, while the second examines the impact of non-uniformity in junction power in terms of the FoM. Modeling results on a chip indicate that uniform power and temperature profiles lead to minimal package irreversibility (and therefore the best thermodynamic performance). As the nonuniformity of power is increased, the performance rapidly degrades, particularly at higher power levels. Additionally, the competing needs of minimization of junction temperature and minimization of cooling power were highlighted using the exergy-based approach. It was shown that for a given power dissipation and a specific cooling architecture (such as an air-cooled heat sink solution), an optimal thermal resistance value exists beyond which the costs of increased cooling may outweigh any potential benefits in performance. Thus, the proposed FoM provides insight into thermofluidic inefficiencies that would be difficult to gain from a traditional first-law analysis. At a minimum, the framework presented in this paper enables quantitative evaluation of package performance for different nonuniform power inputs and different choices of cooling parameters. At best, since the FoM is scalable, the proposed metric has the potential to enable a chip-to-data-center strategy for optimal resource allocation.- 1 December 2005
- Published by ASME International in Journal of Electronic Packaging
- Vol. 128 (4) , 360-369
An Exergy-Based Figure-of-Merit for Electronic Packages
Chip power consumption and heat dissipation have become important design issues because of increased energy costs and thermal management limitations. As a global compute utility evolves, seamless connectivity from the chip to the data center will become increasingly important. The optimization of such an infrastructure will require performance metrics that can adequately capture the thermodynamic and compute behavior at multiple physical length scales. In this paper, an exergy-based figure-of-merit (FoM), defined as the ratio of computing performance (in MIPS) to the thermodynamic performance (in exergy loss), is proposed for the evaluation of computational performance. The paper presents the framework to apply this metric at the chip level. Formulations for the exergy loss in simple air-cooled heat sink packages are developed, and application of the proposed approach is illustrated through two examples. The first comparatively assesses the loss in performance resulting from different cooling solutions, while the second examines the impact of non-uniformity in junction power in terms of the FoM. Modeling results on a chip indicate that uniform power and temperature profiles lead to minimal package irreversibility (and therefore the best thermodynamic performance). As the nonuniformity of power is increased, the performance rapidly degrades, particularly at higher power levels. Additionally, the competing needs of minimization of junction temperature and minimization of cooling power were highlighted using the exergy-based approach. It was shown that for a given power dissipation and a specific cooling architecture (such as an air-cooled heat sink solution), an optimal thermal resistance value exists beyond which the costs of increased cooling may outweigh any potential benefits in performance. Thus, the proposed FoM provides insight into thermofluidic inefficiencies that would be difficult to gain from a traditional first-law analysis. At a minimum, the framework presented in this paper enables quantitative evaluation of package performance for different nonuniform power inputs and different choices of cooling parameters. At best, since the FoM is scalable, the proposed metric has the potential to enable a chip-to-data-center strategy for optimal resource allocation.- 11 November 2005
- Published by ASME International in Journal of Electronic Packaging
- Vol. 128 (2) , 137-144
Viability of Dynamic Cooling Control in a Data Center Environment
Data center thermal management challenges have been steadily increasing over the past few years due to rack level power density increases resulting from system level compaction. These challenges have been compounded by antiquated environmental control strategies designed for low power density installations and for the worst-case heat dissipation rates in the computer systems. Current data center environmental control strategies are not energy efficient when applied to the highly dynamic, high power density data centers of the future. Current techniques control the computer room air conditioning units (CRACs) based on the return air temperature of the air—typically set near . Blowers within the CRACs are normally operated at maximum flow rate throughout the operation of the data center unless they are equipped with nonstandard variable frequency drives. At this setting the blowers typically provide significantly more airflow than is required by the equipment racks to prevent recirculation and the subsequent formation of hot spots. This strategy tends to be overly conservative and inefficient. As an example air entering a given system housed in a rack undergoes a temperature rise of due to the heat added by the system. The return air control strategy strives to keep the entire room at a fixed temperature. Therefore in a typical data center the CRAC supply temperature, and hence the air entering the racks, is and the CRAC return is . At these settings the CRACs can consume almost as much energy as the computer equipment they are cooling [Friedrich, R., Patel, C.D.,2002, “Towards Planetary Scale Computing – Technical Challenges for Next Generation Internet Computing ,” THERMES 2002, Santa Fe, NM; The Uptime Institute, “Heat Density Trends in Data Processing, Computer Systems and Telecommunications Equipment,” White Paper issued by The Uptime Institute, 2000.]. Experiments conducted by the authors using these CRAC settings show that nearly is consumed by the environmental control system for every of heat dissipated by the computer equipment in the authors’ experimental facility indicating that the energy efficiency of standard data center environmental control systems is poor. This study examines several opportunities for improving thermal management and energy performance of data centers with automatic control. Experimental results are presented that demonstrate how simple, modular control strategies can be implemented. Furthermore, experimental data is presented that show it is possible to improve the energy performance of a data center by up to 70% over current standards while maintaining proper thermal management conditions.- 11 November 2005
- Published by ASME International in Journal of Electronic Packaging
- Vol. 128 (2) , 137-144
Viability of Dynamic Cooling Control in a Data Center Environment
Data center thermal management challenges have been steadily increasing over the past few years due to rack level power density increases resulting from system level compaction. These challenges have been compounded by antiquated environmental control strategies designed for low power density installations and for the worst-case heat dissipation rates in the computer systems. Current data center environmental control strategies are not energy efficient when applied to the highly dynamic, high power density data centers of the future. Current techniques control the computer room air conditioning units (CRACs) based on the return air temperature of the air—typically set near . Blowers within the CRACs are normally operated at maximum flow rate throughout the operation of the data center unless they are equipped with nonstandard variable frequency drives. At this setting the blowers typically provide significantly more airflow than is required by the equipment racks to prevent recirculation and the subsequent formation of hot spots. This strategy tends to be overly conservative and inefficient. As an example air entering a given system housed in a rack undergoes a temperature rise of due to the heat added by the system. The return air control strategy strives to keep the entire room at a fixed temperature. Therefore in a typical data center the CRAC supply temperature, and hence the air entering the racks, is and the CRAC return is . At these settings the CRACs can consume almost as much energy as the computer equipment they are cooling [Friedrich, R., Patel, C.D.,2002, “Towards Planetary Scale Computing – Technical Challenges for Next Generation Internet Computing ,” THERMES 2002, Santa Fe, NM; The Uptime Institute, “Heat Density Trends in Data Processing, Computer Systems and Telecommunications Equipment,” White Paper issued by The Uptime Institute, 2000.]. Experiments conducted by the authors using these CRAC settings show that nearly is consumed by the environmental control system for every of heat dissipated by the computer equipment in the authors’ experimental facility indicating that the energy efficiency of standard data center environmental control systems is poor. This study examines several opportunities for improving thermal management and energy performance of data centers with automatic control. Experimental results are presented that demonstrate how simple, modular control strategies can be implemented. Furthermore, experimental data is presented that show it is possible to improve the energy performance of a data center by up to 70% over current standards while maintaining proper thermal management conditions.