YKYasin Kisioglu

Yasin Kisioglu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yasin Kisioglu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The effect of cement on hip stem fixation: a biomechanical study

    by Talip Çelik, İbRahim Mutlu, Arif Özkan, Yasin Kişioğlu

    This study presents the numerical analysis of stem fixation in hip surgery using with/without cement methods since the use of cement is still controversial based on the clinical studies in the literature. Many different factors such as stress shielding, aseptic loosening, material properties of the stem, surgeon experiences etc. play an important role in the failure of the stem fixations. The stem fixation methods, cemented and uncemented, were evaluated in terms of mechanical failure aspects using computerized finite element method. For the modeling processes, three dimensional (3D) femur model was generated from computerized tomography (CT) images taken from a patient using the MIMICS Software. The design of the stem was also generated as 3D CAD model using the design parameters taken from the manufacturer catalogue. These 3D CAD models were generated and combined with/without cement considering the surgical procedure using SolidWorks program and then imported into ANSYS Workbench Software. Two different material properties, CoCrMo and Ti6Al4V, for the stem model and Poly Methyl Methacrylate (PMMA) for the cement were assigned. The material properties of the femur were described according to a density calculated from the CT images. Body weight and muscle forces were applied on the femur and the distal femur was fixed for the boundary conditions. The calculations of the stress distributions of the models including cement and relative movements of the contacts examined to evaluate the effects of the cement and different stem material usage on the failure of stem fixation. According to the results, the use of cement for the stem fixation reduces the stress shielding but increases the aseptic loosening depending on the cement crack formations. Additionally, using the stiffer material for the stem reduces the cement stress but increases the stress shielding. Based on the results obtained in the study, even when taking the disadvantages into account, the cement usage is more suitable for the hip fixations.


  • Fatigue Performance Evaluations of Vehicle Toroidal Liquefied Petroleum Gas Fuel Tanks

    by Fuat Kartal, Yasin Kisioglu

    In this study, fatigue performances of the vehicle toroidal liquefied petroleum gas (LPG) fuel tanks were examined to estimate the fatigue life and its failure locations using both experimental and finite element analysis (FEA) methods. The experimental investigations performed as accelerated fatigue tests were carried out using a hydraulics test unit in which the tanks were internally pressurized by hydraulic oil. The LPG tanks were subjected to repeated cyclic pressure load varying from zero to service pressure (SP) of the tank. The computerized FEA modeling of these tanks were developed in three-dimensional (3D) form using nonuniform geometrical parameters and nonlinear material properties. These models were also subjected to zero-based high cycle fatigue pressure load considering the stress life approach. The FEA modeling process was also simulated in nonhomogeneous material conditions. Therefore, the fatigue life performance and failure location of the toroidal LPG fuel tanks were predicted using the computer-aided simulations and compared with the experimental results.


  • How does the material variation of dynamic hip screw affect the cut-out risk in the treatment of intertrochanteric femoral fractures?

    by Yasin Kisioglu, Ibrahim Mutlu, Arif Ozkan, Talip Celik

    The material selection of dynamic hip screw (DHS) is not usually considered from the point of mechanical effects. In this study, the effects of the titanium alloy and stainless steel DHS was investigated in the cut-out risk of femur using finite element analysis (FEA). Intertrochanteric femur fracture (IFF) (31-A2 type according to AO classification) was created in the 3D femur model obtained from computer tomography images. The DHS model was inserted to the fractured femur model in two different positions (inferior and middle). The material properties of DHS were defined for the FEA. The force applied to the femoral head was determined according to the maximum value that is observed during walking. The results show that the safest model was obtained in the middle placement of titanium alloy DHS according to the safety factor. Consequently, the use of stainless steel DHS for IFF could cause higher failure risk of DHS than the use of titanium alloy DHS.

    • 1 January 2014
      • Vol. 16  (2) , 111-20

    Evaluation of contact characteristics of a patient-specific artificial dysplastic hip joint.

    by Ibrahim Mutlu, Levent Ugur, Talip Celik, Levent Buluc, Umit Sefa Muezzinoglu, Yasin Kisioglu

    This study addresses the results of the experimental measurements for the contact surface areas and contact pressure distributions of a dysplastic hip joint. The hip joint consists of pelvis, proximal femur and artificial cartilages for both acetabulum and femoral head. The dysplastic hip joint is modeled in three dimensional (3D) form using the computerized tomography (CT) images obtained in vivo of an adult female patient. The modeled hip joint components are manufactured as a non-natural dysplastic hip joint using different materials and manufacturing processes. The dysplastic hip joint produced is subjected to compression forces experimentally to measure the contact surface area and contact pressure distributions between the femoral head and acetabulum using the pressure sensitive Fuji film. Different types of specific fixtures and molds are designed and manufactured to produce the dysplastic hip joint components and perform the experimental studies. The measured results using a non-natural dysplastic hip joint are compared with relevant results reported in current literature considering the peak and mean contact pressure values. Therefore, the obtained results showed that the non-natural dysplastic hip models can be generated and replaced to determine the contact characteristics for an elusive cadaveric model. In conclusion, the artificial models might be useful to understand the contact pressure distributions and potential changes in surface pressure contours and their effects on the stress distributions.


    • 1 January 2013
      • Vol. 15  (4) , 67-72

    Stress distribution comparisons of foot bones in patient with tibia vara: a finite element study.

    by Arif Ozkan, Halil Atmaca, Ibrahim Mutlu, Talip Celik, Levent Uğur, Yasin Kişioğlu

    Blount's disease, or tibia vara, is the most common cause of pathologic genu varum in children and adolescents. Changes in the loading of knee structures such as tibial articular cartilage, menisci and subcondral bone are well documented in case of genu varum. But the mechanical effects of this condition on foot bones are still questionable. In this study, the authors hypothesized that stress distributions on foot bones might increase in patients with tibia vara when compared with patients who had normal lower extremity mechanical axis. Three-dimensional (3D) finite element analyses of human lower limb were used to investigate and compare the loading on foot bones in normal population and patient with tibia vara. The segmentation software, MIMICS was used to generate the 3D images of the bony structures of normal and varus malalignment lower extremity. Except the spaces between the adjacent surface of the phalanges fused, metatarsals, cuneiforms, cuboid, navicular, talus and calcaneus bones were independently developed to form foot and ankle complex. Also femur, tibia and fibula were modeled utilizing mechanical axis. ANSYS version 14 was used for mechanical tests and maximum equivalent stresses (MES) were examined. As a result of the loading conditions, in varus model MES on talus, calcaneus and cuboid were found higher than in normal model. And stress distributions changed through laterally on middle and fore foot in varus deformity model.


  • Burst Pressure Determination of Vehicle Toroidal Oval Cross-Section LPG Fuel Tanks

    by Yasin Kisioglu

    This study addresses the prediction of the burst pressures and burst failure locations of the vehicle toroidal liquefied petroleum gas (LPG) fuel tanks using both experimental and finite element analysis (FEA) approaches. The experimental burst test investigations were carried out hydrostatically in which the cylinders were internally pressurized with water. The FEA modeling processes of these LPG fuel tanks subjected to incremental internal uniform pressure were performed in the nonlinear field. Two different types of nonlinear models, plane and shell, were developed and evaluated under nonuniform and axisysmmetric boundary conditions. The required actual shell properties including weld zone and shell thickness variations were also investigated and used in the computerized modeling processes. Therefore, the results of the burst pressures and their failure locations were predicted and compared with experimental ones.