Ibrahim Mutlu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ibrahim Mutlu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Talip Çelik
Department of Biomedical Engineering, Institute of Natural and Applied Sciences, Kocaeli University, 41001 Kocaeli, Turkey
6 shared publications - Yasin Kisioglu
Department of Biomedical Engineering, Kocaeli University, Umuttepe Campus, 41380, Kocaeli, Turkey
5 shared publications - Arif Özkan
Kocaeli Üniversitesi
2 shared publications Arif Ozkan
1 shared publication- Arif Ozkan
Department of Biomedical Engineering, Duzce University Faculty of Engineering, Duzce
1 shared publication - Arif Özkan
Department of Biomedical Engineering, Duzce University, Konuralp Campus, 81620, Duzce, Turkey
1 shared publication
Latest Publications
- Open Access
Influence of Form Factor on Microstructural, Mechanical and Electrical Properties of Electrically Conductive Polyvinylidene Fluoride Processed by Arburg Plastic Freeforming
The utilization of polymer-based additive manufacturing processes for the production of functional components, consumer goods, spare parts, etc., has increased thanks to recent technological advances. The Arburg Plastic Freeforming (APF) process is a promising AM technology, in which standard plastic granules are deployed, and droplets are discharged along a track instead of using continuously extruded straws, unlike other filament-based processes, to the benefit of various industries that require good mechanical properties while maintaining dimensional precision. Due to the round shape of the droplets and tracks, however, defects such as voids can occur between individual paths during processing, which affect, most notably, mechanical properties. The electrical/ferroelectric properties of conductive/electroactive polymers are also affected. This study focuses on determining the optimal form factor for processing a special grade polyvinylidene fluoride (PVDF) material whilst other parameters, along with the ones ascertained in previous work, are kept constant. Along with tensile tests, X-ray computed microtomography (µ-CT) and scanning electron microscopy (SEM) analyses are implemented, particularly to observe microstructural porosity. Electrical properties and possible piezoelectric behavior are investigated via an originally adapted analytical method. The results provide important insights into the APF process and printing high-performance plastics with individual features, expanding the potential for further applications.
Open AccessInfluence of Form Factor on Microstructural, Mechanical and Electrical Properties of Electrically Conductive Polyvinylidene Fluoride Processed by Arburg Plastic Freeforming
The utilization of polymer-based additive manufacturing processes for the production of functional components, consumer goods, spare parts, etc., has increased thanks to recent technological advances. The Arburg Plastic Freeforming (APF) process is a promising AM technology, in which standard plastic granules are deployed, and droplets are discharged along a track instead of using continuously extruded straws, unlike other filament-based processes, to the benefit of various industries that require good mechanical properties while maintaining dimensional precision. Due to the round shape of the droplets and tracks, however, defects such as voids can occur between individual paths during processing, which affect, most notably, mechanical properties. The electrical/ferroelectric properties of conductive/electroactive polymers are also affected. This study focuses on determining the optimal form factor for processing a special grade polyvinylidene fluoride (PVDF) material whilst other parameters, along with the ones ascertained in previous work, are kept constant. Along with tensile tests, X-ray computed microtomography (µ-CT) and scanning electron microscopy (SEM) analyses are implemented, particularly to observe microstructural porosity. Electrical properties and possible piezoelectric behavior are investigated via an originally adapted analytical method. The results provide important insights into the APF process and printing high-performance plastics with individual features, expanding the potential for further applications.
- 27 March 2023
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 26 (1) , 73-79
Geleneksel Total Kalça Protezine Alternatif Epifiz Protezinin Mekanik Değerlendirmesi
Bu çalışmada kısa saplı ve uzun saplı kalça protezleri mekanik açıdan karşılaştırılmıştır. Protez ve kemikler bilgisayar ortamında modellenmiş ve protezlerin mekanik performansını incelemek amacıyla birleştirilmiştir. Sonuçların değerlendirilmesi için protez komponentleri ve çimentoda oluşan eş değer gerilme (von Mises) değerleri dikkate alınmıştır. Sonuç olarak, total kalça ameliyatlarında kısa saplı protez kullanımın implant hasar açısından daha avantajlı olduğu ve tasarımsal iyileştirmeler yaparak uzun saplı kalça protezinin yerini alma potansiyeline sahip olabileceği öngörülmüştür.
- 27 March 2023
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 26 (1) , 73-79
Geleneksel Total Kalça Protezine Alternatif Epifiz Protezinin Mekanik Değerlendirmesi
Bu çalışmada kısa saplı ve uzun saplı kalça protezleri mekanik açıdan karşılaştırılmıştır. Protez ve kemikler bilgisayar ortamında modellenmiş ve protezlerin mekanik performansını incelemek amacıyla birleştirilmiştir. Sonuçların değerlendirilmesi için protez komponentleri ve çimentoda oluşan eş değer gerilme (von Mises) değerleri dikkate alınmıştır. Sonuç olarak, total kalça ameliyatlarında kısa saplı protez kullanımın implant hasar açısından daha avantajlı olduğu ve tasarımsal iyileştirmeler yaparak uzun saplı kalça protezinin yerini alma potansiyeline sahip olabileceği öngörülmüştür.
- Open Access
- 30 April 2022
- Published by International Journal of 3D Printing Technologies and Digital Industry in International Journal of 3D Printing Technologies and Digital Industry
- Vol. 6 (1) , 137-142
PARÇALI OLARAK ÜRETİLEN 3 BOYUTLU YAZICI ÇIKTILARINDA KULLANILAN BAĞLANTI TİPLERİNİN MEKANİK AÇIDAN DEĞERLENDİRİLMESİ
Üç boyutlu (3B) yazıcı teknolojisi, günümüzde sıklıkla tercih edilmeye başlayan, önemli ve popüler teknolojidir. Bu teknoloji gelecekte üretimin farklı alanlarında kullanılabilir olması ile tasarımdaki kısıtlılıklar tamamen ortadan kalkacaktır. Bununla birlikte, 3B yazıcı teknolojisi sınırlı yapı hacmine sahiptir. Bu sebeple, oluşturulan hacim parçalı tasarlanır ve bu parçalar gövdeyi oluşturmak için birbirine bağlanır. Hacimce büyük bir modelin 3B yazıcılardan çıktısını alırken bölümlendirilmiş parçaların bağlantısı çeşitli bağlantı tipleri ile yapılabilmektedir. Bu çalışmanın amacı, 3B yazıcı ile imal edilen parçalı bir üründe kullanılan bağlantı tiplerinin mukavemet açısından değerlendirmek ve en uygun bağlantı tipini belirlemektir. Bu çalışmada, parçaları birbirine bağlamak için dört farklı bağlantı tipi oluşturulmuştur. Bu bağlantı tiplerinin mukavemetini değerlendirmek için standart çekme numunesi tasarımı yapılmış ve bu tasarım ortadan ikiye ayrılarak üretilmiştir. İki parça olarak üretilen çekme numunesi japon yapıştırıcısı (siyanoakrilat), pim, kaynak ve hem kaynak hem de yapıştırıcı (siyanoakrilat) ile birbirine bağlanmıştır. Çekme numunesinin parçalanmamış tek parçalı hali referans numune olarak üretilmiştir. Her grup için yedişer adet üretilen parçalar, üniversal çekme test cihazı ile çekme testine tabi tutulmuştur. Çekme testi sonunda, maksimum çekme kuvveti ve yer değiştirme değerleri elde edilmiş ve bu değerlere göre gerilme, gerinim ve elastik modülleri hesaplanmıştır. Sonuç olarak, 3B kalem kullanılarak yapılan kaynakta en yüksek gerilme ve elastik modül değerleri hesaplanmıştır. Pim ile birbirine bağlanan parçaların en düşük mukavemete sahip olduğu belirlenmiştir. Referans model ile karşılaştırıldığında, tüm bağlantı tipleri parça mukavemetinde minimum %37 azalmaya yol açmıştır. Elde edilen sonuçlara göre, mukavemeti en iyi sağlayan bağlantı tipi 3B yazıcı kalemi kullanılarak yapılan kaynak bağlantı tipidir.
- 30 April 2022
- Published by International Journal of 3D Printing Technologies and Digital Industry in International Journal of 3D Printing Technologies and Digital Industry
- Vol. 6 (1) , 137-142
Open AccessPARÇALI OLARAK ÜRETİLEN 3 BOYUTLU YAZICI ÇIKTILARINDA KULLANILAN BAĞLANTI TİPLERİNİN MEKANİK AÇIDAN DEĞERLENDİRİLMESİ
Üç boyutlu (3B) yazıcı teknolojisi, günümüzde sıklıkla tercih edilmeye başlayan, önemli ve popüler teknolojidir. Bu teknoloji gelecekte üretimin farklı alanlarında kullanılabilir olması ile tasarımdaki kısıtlılıklar tamamen ortadan kalkacaktır. Bununla birlikte, 3B yazıcı teknolojisi sınırlı yapı hacmine sahiptir. Bu sebeple, oluşturulan hacim parçalı tasarlanır ve bu parçalar gövdeyi oluşturmak için birbirine bağlanır. Hacimce büyük bir modelin 3B yazıcılardan çıktısını alırken bölümlendirilmiş parçaların bağlantısı çeşitli bağlantı tipleri ile yapılabilmektedir. Bu çalışmanın amacı, 3B yazıcı ile imal edilen parçalı bir üründe kullanılan bağlantı tiplerinin mukavemet açısından değerlendirmek ve en uygun bağlantı tipini belirlemektir. Bu çalışmada, parçaları birbirine bağlamak için dört farklı bağlantı tipi oluşturulmuştur. Bu bağlantı tiplerinin mukavemetini değerlendirmek için standart çekme numunesi tasarımı yapılmış ve bu tasarım ortadan ikiye ayrılarak üretilmiştir. İki parça olarak üretilen çekme numunesi japon yapıştırıcısı (siyanoakrilat), pim, kaynak ve hem kaynak hem de yapıştırıcı (siyanoakrilat) ile birbirine bağlanmıştır. Çekme numunesinin parçalanmamış tek parçalı hali referans numune olarak üretilmiştir. Her grup için yedişer adet üretilen parçalar, üniversal çekme test cihazı ile çekme testine tabi tutulmuştur. Çekme testi sonunda, maksimum çekme kuvveti ve yer değiştirme değerleri elde edilmiş ve bu değerlere göre gerilme, gerinim ve elastik modülleri hesaplanmıştır. Sonuç olarak, 3B kalem kullanılarak yapılan kaynakta en yüksek gerilme ve elastik modül değerleri hesaplanmıştır. Pim ile birbirine bağlanan parçaların en düşük mukavemete sahip olduğu belirlenmiştir. Referans model ile karşılaştırıldığında, tüm bağlantı tipleri parça mukavemetinde minimum %37 azalmaya yol açmıştır. Elde edilen sonuçlara göre, mukavemeti en iyi sağlayan bağlantı tipi 3B yazıcı kalemi kullanılarak yapılan kaynak bağlantı tipidir.
- 3 April 2022
- Published by Journal of Healthcare Management and Leadership in Journal of Healthcare Management and Leadership
- No. 1,p. 48-58
ÖZEL BİR HASTANEDE PERKÜTAN KORONER GİRİŞİM VERİLERİNİN İNCELENMESİ
Bu çalışmada, perkütan koroner girişimleri detaylandırılarak yapılan hizmet sayıları ile bu işlemlerin maliyetlerine yönelik inceleme yapılmıştır. Kocaeli ilinde bir özel hastanede kardiyoloji bölümüne başvuran hastalara uygulanan 2018 yılı birinci ayından 2019 yılı üçüncü ayının sonuna kadar olan veriler değerlendirmeye alınmıştır. İncelememiz sonucunda erkek hastaların kadın hastalara oranla yaklaşık iki kat daha fazla olduğu gözlemlenmiştir. Yapılan işlem adet sayılarının özellikle yaz aylarında azaldığı ve kış aylarına doğru artış gösterdiği tespit edilmiştir. Elde edilen veriler ışığında, kişilerin kalp sağlığı açısından kış aylarına dikkat etmeleri gerektiği ortaya konulmuştur. Ayrıca 61-75 yaş aralığının en fazla işlem yapılan yaş olduğu ortaya çıkmıştır. Maliyet açısından en fazla maliyetin ilaçlı stent olduğu anlaşılmaktadır. Bu kapsamda, ortalama yaşlardaki hastalar için yapılan işlemlerin kurumlara fazla yük getirdiği anlaşılmaktadır. Toplum kalp sağlığı açısından kurumlara yansıyan maliyetler de düşünülerek çıkarımlar yapılırsa, sağlık harcamalarının düşürülmesi adına ülkemizde bireylerde sağlığı koruma bilincinin artırılmasının hem birey hem de devlet adına yarar sağlayacağı öngörülmüştür.
- 3 April 2022
- Published by Journal of Healthcare Management and Leadership in Journal of Healthcare Management and Leadership
- No. 1,p. 48-58
ÖZEL BİR HASTANEDE PERKÜTAN KORONER GİRİŞİM VERİLERİNİN İNCELENMESİ
Bu çalışmada, perkütan koroner girişimleri detaylandırılarak yapılan hizmet sayıları ile bu işlemlerin maliyetlerine yönelik inceleme yapılmıştır. Kocaeli ilinde bir özel hastanede kardiyoloji bölümüne başvuran hastalara uygulanan 2018 yılı birinci ayından 2019 yılı üçüncü ayının sonuna kadar olan veriler değerlendirmeye alınmıştır. İncelememiz sonucunda erkek hastaların kadın hastalara oranla yaklaşık iki kat daha fazla olduğu gözlemlenmiştir. Yapılan işlem adet sayılarının özellikle yaz aylarında azaldığı ve kış aylarına doğru artış gösterdiği tespit edilmiştir. Elde edilen veriler ışığında, kişilerin kalp sağlığı açısından kış aylarına dikkat etmeleri gerektiği ortaya konulmuştur. Ayrıca 61-75 yaş aralığının en fazla işlem yapılan yaş olduğu ortaya çıkmıştır. Maliyet açısından en fazla maliyetin ilaçlı stent olduğu anlaşılmaktadır. Bu kapsamda, ortalama yaşlardaki hastalar için yapılan işlemlerin kurumlara fazla yük getirdiği anlaşılmaktadır. Toplum kalp sağlığı açısından kurumlara yansıyan maliyetler de düşünülerek çıkarımlar yapılırsa, sağlık harcamalarının düşürülmesi adına ülkemizde bireylerde sağlığı koruma bilincinin artırılmasının hem birey hem de devlet adına yarar sağlayacağı öngörülmüştür.
- 17 September 2021
- Published by Bitlis Eren Universitesi Fen Bilimleri Dergisi in Bitlis Eren Üniversitesi Fen Bilimleri Dergisi
- Vol. 10 (3) , 920-929
A Statistical Approach To Measure Uniformity Of Fuji Prescale Pressure Sensitive Film Samples
Fuji prescale pressure sensitive films (FPPSF) are generally used in biomechanical applications to measure the pressure distributions and the contact areas between two contact surfaces as in coloured stains. FPPSFs are usually calibrated based on the calibration methods using regression analysis to obtain a specific calibration curve. However, researchers in literature achieve different calibration curves based upon their tests and different processes. The purpose of this study is to examine the calibration stains (data) obtained experimentally using the FPPSF samples compressed between two smooth flat surfaces to indicate contact pressures. The gray-level co-occurrence matrix (GLCM) was used to evaluate the uniformity of the sample stains for quantitative evaluation of uniform distribution of the sample stains. Moreover, the generated calibration data is also compared and validated statistically with the related calibration curves presented in the available literature. As a result, the parameter of energy property of GLCM can be practicable to check the image uniformity of samples in order for performing the accuracy of a generated curve.
- 17 September 2021
- Published by Bitlis Eren Universitesi Fen Bilimleri Dergisi in Bitlis Eren Üniversitesi Fen Bilimleri Dergisi
- Vol. 10 (3) , 920-929
A Statistical Approach To Measure Uniformity Of Fuji Prescale Pressure Sensitive Film Samples
Fuji prescale pressure sensitive films (FPPSF) are generally used in biomechanical applications to measure the pressure distributions and the contact areas between two contact surfaces as in coloured stains. FPPSFs are usually calibrated based on the calibration methods using regression analysis to obtain a specific calibration curve. However, researchers in literature achieve different calibration curves based upon their tests and different processes. The purpose of this study is to examine the calibration stains (data) obtained experimentally using the FPPSF samples compressed between two smooth flat surfaces to indicate contact pressures. The gray-level co-occurrence matrix (GLCM) was used to evaluate the uniformity of the sample stains for quantitative evaluation of uniform distribution of the sample stains. Moreover, the generated calibration data is also compared and validated statistically with the related calibration curves presented in the available literature. As a result, the parameter of energy property of GLCM can be practicable to check the image uniformity of samples in order for performing the accuracy of a generated curve.
- 20 March 2017
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 40 (2) , 349-357
The effect of cement on hip stem fixation: a biomechanical study
This study presents the numerical analysis of stem fixation in hip surgery using with/without cement methods since the use of cement is still controversial based on the clinical studies in the literature. Many different factors such as stress shielding, aseptic loosening, material properties of the stem, surgeon experiences etc. play an important role in the failure of the stem fixations. The stem fixation methods, cemented and uncemented, were evaluated in terms of mechanical failure aspects using computerized finite element method. For the modeling processes, three dimensional (3D) femur model was generated from computerized tomography (CT) images taken from a patient using the MIMICS Software. The design of the stem was also generated as 3D CAD model using the design parameters taken from the manufacturer catalogue. These 3D CAD models were generated and combined with/without cement considering the surgical procedure using SolidWorks program and then imported into ANSYS Workbench Software. Two different material properties, CoCrMo and Ti6Al4V, for the stem model and Poly Methyl Methacrylate (PMMA) for the cement were assigned. The material properties of the femur were described according to a density calculated from the CT images. Body weight and muscle forces were applied on the femur and the distal femur was fixed for the boundary conditions. The calculations of the stress distributions of the models including cement and relative movements of the contacts examined to evaluate the effects of the cement and different stem material usage on the failure of stem fixation. According to the results, the use of cement for the stem fixation reduces the stress shielding but increases the aseptic loosening depending on the cement crack formations. Additionally, using the stiffer material for the stem reduces the cement stress but increases the stress shielding. Based on the results obtained in the study, even when taking the disadvantages into account, the cement usage is more suitable for the hip fixations.
- 20 March 2017
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 40 (2) , 349-357
The effect of cement on hip stem fixation: a biomechanical study
This study presents the numerical analysis of stem fixation in hip surgery using with/without cement methods since the use of cement is still controversial based on the clinical studies in the literature. Many different factors such as stress shielding, aseptic loosening, material properties of the stem, surgeon experiences etc. play an important role in the failure of the stem fixations. The stem fixation methods, cemented and uncemented, were evaluated in terms of mechanical failure aspects using computerized finite element method. For the modeling processes, three dimensional (3D) femur model was generated from computerized tomography (CT) images taken from a patient using the MIMICS Software. The design of the stem was also generated as 3D CAD model using the design parameters taken from the manufacturer catalogue. These 3D CAD models were generated and combined with/without cement considering the surgical procedure using SolidWorks program and then imported into ANSYS Workbench Software. Two different material properties, CoCrMo and Ti6Al4V, for the stem model and Poly Methyl Methacrylate (PMMA) for the cement were assigned. The material properties of the femur were described according to a density calculated from the CT images. Body weight and muscle forces were applied on the femur and the distal femur was fixed for the boundary conditions. The calculations of the stress distributions of the models including cement and relative movements of the contacts examined to evaluate the effects of the cement and different stem material usage on the failure of stem fixation. According to the results, the use of cement for the stem fixation reduces the stress shielding but increases the aseptic loosening depending on the cement crack formations. Additionally, using the stiffer material for the stem reduces the cement stress but increases the stress shielding. Based on the results obtained in the study, even when taking the disadvantages into account, the cement usage is more suitable for the hip fixations.
- 1 January 2016
- Published by Inderscience Publishers in International Journal of Experimental and Computational Biomechanics
- Vol. 4 (1) , 49
How does the material variation of dynamic hip screw affect the cut-out risk in the treatment of intertrochanteric femoral fractures?
The material selection of dynamic hip screw (DHS) is not usually considered from the point of mechanical effects. In this study, the effects of the titanium alloy and stainless steel DHS was investigated in the cut-out risk of femur using finite element analysis (FEA). Intertrochanteric femur fracture (IFF) (31-A2 type according to AO classification) was created in the 3D femur model obtained from computer tomography images. The DHS model was inserted to the fractured femur model in two different positions (inferior and middle). The material properties of DHS were defined for the FEA. The force applied to the femoral head was determined according to the maximum value that is observed during walking. The results show that the safest model was obtained in the middle placement of titanium alloy DHS according to the safety factor. Consequently, the use of stainless steel DHS for IFF could cause higher failure risk of DHS than the use of titanium alloy DHS.
- 1 January 2016
- Published by Inderscience Publishers in International Journal of Experimental and Computational Biomechanics
- Vol. 4 (1) , 49
How does the material variation of dynamic hip screw affect the cut-out risk in the treatment of intertrochanteric femoral fractures?
The material selection of dynamic hip screw (DHS) is not usually considered from the point of mechanical effects. In this study, the effects of the titanium alloy and stainless steel DHS was investigated in the cut-out risk of femur using finite element analysis (FEA). Intertrochanteric femur fracture (IFF) (31-A2 type according to AO classification) was created in the 3D femur model obtained from computer tomography images. The DHS model was inserted to the fractured femur model in two different positions (inferior and middle). The material properties of DHS were defined for the FEA. The force applied to the femoral head was determined according to the maximum value that is observed during walking. The results show that the safest model was obtained in the middle placement of titanium alloy DHS according to the safety factor. Consequently, the use of stainless steel DHS for IFF could cause higher failure risk of DHS than the use of titanium alloy DHS.
- 1 January 2014
- Vol. 16 (2) , 111-20
Evaluation of contact characteristics of a patient-specific artificial dysplastic hip joint.
This study addresses the results of the experimental measurements for the contact surface areas and contact pressure distributions of a dysplastic hip joint. The hip joint consists of pelvis, proximal femur and artificial cartilages for both acetabulum and femoral head. The dysplastic hip joint is modeled in three dimensional (3D) form using the computerized tomography (CT) images obtained in vivo of an adult female patient. The modeled hip joint components are manufactured as a non-natural dysplastic hip joint using different materials and manufacturing processes. The dysplastic hip joint produced is subjected to compression forces experimentally to measure the contact surface area and contact pressure distributions between the femoral head and acetabulum using the pressure sensitive Fuji film. Different types of specific fixtures and molds are designed and manufactured to produce the dysplastic hip joint components and perform the experimental studies. The measured results using a non-natural dysplastic hip joint are compared with relevant results reported in current literature considering the peak and mean contact pressure values. Therefore, the obtained results showed that the non-natural dysplastic hip models can be generated and replaced to determine the contact characteristics for an elusive cadaveric model. In conclusion, the artificial models might be useful to understand the contact pressure distributions and potential changes in surface pressure contours and their effects on the stress distributions.
- 1 January 2014
- Vol. 16 (2) , 111-20
Evaluation of contact characteristics of a patient-specific artificial dysplastic hip joint.
This study addresses the results of the experimental measurements for the contact surface areas and contact pressure distributions of a dysplastic hip joint. The hip joint consists of pelvis, proximal femur and artificial cartilages for both acetabulum and femoral head. The dysplastic hip joint is modeled in three dimensional (3D) form using the computerized tomography (CT) images obtained in vivo of an adult female patient. The modeled hip joint components are manufactured as a non-natural dysplastic hip joint using different materials and manufacturing processes. The dysplastic hip joint produced is subjected to compression forces experimentally to measure the contact surface area and contact pressure distributions between the femoral head and acetabulum using the pressure sensitive Fuji film. Different types of specific fixtures and molds are designed and manufactured to produce the dysplastic hip joint components and perform the experimental studies. The measured results using a non-natural dysplastic hip joint are compared with relevant results reported in current literature considering the peak and mean contact pressure values. Therefore, the obtained results showed that the non-natural dysplastic hip models can be generated and replaced to determine the contact characteristics for an elusive cadaveric model. In conclusion, the artificial models might be useful to understand the contact pressure distributions and potential changes in surface pressure contours and their effects on the stress distributions.
- 1 January 2013
- Vol. 15 (4) , 67-72
Stress distribution comparisons of foot bones in patient with tibia vara: a finite element study.
Blount's disease, or tibia vara, is the most common cause of pathologic genu varum in children and adolescents. Changes in the loading of knee structures such as tibial articular cartilage, menisci and subcondral bone are well documented in case of genu varum. But the mechanical effects of this condition on foot bones are still questionable. In this study, the authors hypothesized that stress distributions on foot bones might increase in patients with tibia vara when compared with patients who had normal lower extremity mechanical axis. Three-dimensional (3D) finite element analyses of human lower limb were used to investigate and compare the loading on foot bones in normal population and patient with tibia vara. The segmentation software, MIMICS was used to generate the 3D images of the bony structures of normal and varus malalignment lower extremity. Except the spaces between the adjacent surface of the phalanges fused, metatarsals, cuneiforms, cuboid, navicular, talus and calcaneus bones were independently developed to form foot and ankle complex. Also femur, tibia and fibula were modeled utilizing mechanical axis. ANSYS version 14 was used for mechanical tests and maximum equivalent stresses (MES) were examined. As a result of the loading conditions, in varus model MES on talus, calcaneus and cuboid were found higher than in normal model. And stress distributions changed through laterally on middle and fore foot in varus deformity model.
- 1 January 2013
- Vol. 15 (4) , 67-72
Stress distribution comparisons of foot bones in patient with tibia vara: a finite element study.
Blount's disease, or tibia vara, is the most common cause of pathologic genu varum in children and adolescents. Changes in the loading of knee structures such as tibial articular cartilage, menisci and subcondral bone are well documented in case of genu varum. But the mechanical effects of this condition on foot bones are still questionable. In this study, the authors hypothesized that stress distributions on foot bones might increase in patients with tibia vara when compared with patients who had normal lower extremity mechanical axis. Three-dimensional (3D) finite element analyses of human lower limb were used to investigate and compare the loading on foot bones in normal population and patient with tibia vara. The segmentation software, MIMICS was used to generate the 3D images of the bony structures of normal and varus malalignment lower extremity. Except the spaces between the adjacent surface of the phalanges fused, metatarsals, cuneiforms, cuboid, navicular, talus and calcaneus bones were independently developed to form foot and ankle complex. Also femur, tibia and fibula were modeled utilizing mechanical axis. ANSYS version 14 was used for mechanical tests and maximum equivalent stresses (MES) were examined. As a result of the loading conditions, in varus model MES on talus, calcaneus and cuboid were found higher than in normal model. And stress distributions changed through laterally on middle and fore foot in varus deformity model.