KBKlaus Brun

Klaus Brun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Klaus Brun has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Deposition Pattern Analysis on a Fouled Multistage Test Compressor

    by Alessio Suman, Alessandro Vulpio, Nicola Casari, Michele Pinelli, Rainer Kurz, Klaus Brun

    Compressor fouling is one of the main causes of gas turbine performance degradation. Microsized particles adhere to the blade surfaces increasing the surface roughness and modifying the airfoil shape. In this work, the contamination of the Allison 250 C18 multistage compressor engine with four sorts of micrometric dust has been provided. The tests were performed changing the relative humidity (RH) at the compressor inlet and the unit rotational speed. After each test, a photographic inspection of the internal fouled parts has been realized and the digital pictures have been analyzed employing an image processing package. The deposit's build-up of stator vanes and rotor blades has been postprocessed and the most affected regions of each compressor stage have been highlighted. Besides, a numerical simulation of the machine has been performed. The numerical flow field has been used to highlight the blade regions, which show the most favorable conditions for particle deposition. A theoretical model has been applied to the flow field to simulate the particle deposition. The combination of the deposition model with the results of the numerical simulations gives the chance to better understand the experimentally founded deposition patterns. Those results have been finally compared to the pictures of the patterns. The possibility to detect and measure the deposition patterns on a rotating test rig and the comparison with models and experiments gave the possibility to assess in detail the particle deposition phenomenon on a multistage axial compressor flow path.


  • Compressor Speed Decay During Emergency Shutdowns

    by Rainer Kurz, Sean Garceau, Min Ji, Klaus Brun

    The emergency shutdown of a compressor train is a necessary safety feature. In this event, the power supply (either from a gas turbine or an electric motor) is cut off. The compressor train will continue to spin due to its inertia, but the speed will reduce fast. To avoid damage of the equipment during a shutdown event, compressor surge must to be avoided. In many instances, the dynamic behavior of the compression system is simulated to ensure that the necessary recycle valves are sized, and arranged properly. One of the key problems of dynamic simulation, and a major source of uncertainty in the results, is the correct treatment of the speed decay of the compressor train. The present study provides the background to evaluate the speed decay, and includes data from actual rundown situations. The evaluation shows general trends, that can be used to reduce the simulation uncertainties in dynamic simulations.


  • A New Index to Evaluate the Potential Damage of a Surge Event: The Surge Severity Coefficient

    by Enrico Munari, Mirko Morini, Michele Pinelli, Klaus Brun, Sarah Simons, Rainer Kurz

    Industrial compressors suffer from strong aerodynamic instability that arises when low ranges of flow rate are achieved; this instability is called surge. This phenomenon creates strong vibrations and forces acting on the compressor and system components due to the fact that it produces variable time-averaged mass flow and pressure. Therefore, surge is dangerous not only for aerodynamic structures but also for mechanical parts. Surge is usually prevented in industrial plants by means of anti-surge systems, which act as soon as surge occurs; however, some rapid transients or system upsets can lead the compressor to surge anyway. Despite the fact that surge can be classified as mild, classic, or deep, depending on the amplitudes and frequency of the fluctuations, operators are used to simply referring to surge, without making a distinction between the three main classes. This is one of the reasons why, when surge occurs in industrial plants, it is a common practice to stop the machine to perform inspections and check if any damage occurred. Obviously, this implies maintenance costs and time, during which the machine does not operate. On the other hand, not all surge events are dangerous in terms of damage, and they can be tolerated by the mechanical structures of the compressor; thus, in these cases, inspections would not be required. Unfortunately, a method for establishing the potential damage of a surge event is not available in literature. In order to fill this gap, this paper proposes a final formulation of a surge severity index, which was only preliminarily formulated by the authors in a previous work. The preliminary form of this coefficient demonstrated some limitations, which are overcome in this paper. The surge severity index derives from an energy-force based analysis. The coefficient demonstration is carried out in this paper by means of (i) the application of the Buckingham's Pi-theorem, and (ii) a careful analysis of the causative and restorative factors of surge. Finally, some simple practical evaluations are shown by means of a sensitivity analysis, using simulation results of an existing model, to effectively further highlight the consistency of this coefficient for industry.


  • A Method and Apparatus for Direct Enthalpy Rise Measurement for Gas Compression

    by Klaus Brun, Sarah Simons, Kelsi Katcher, Ryan Cater, Brandon Ridens, Rainer Kurz

    Gas property prediction is necessary for proper design of compressors. Equations of state are utilized to predict the thermo-physical gas properties needed for such calculations. These are semi-empirical models that allow the calculation of thermodynamic properties such as density, enthalpy, and speed of sound of gas mixtures for known pressures and temperature. Currently, there is limited or no data publically available to verify the results of these equation of state calculations for the range of pressures, temperatures, and gas compositions relevant to many oil and gas applications. Especially for isentropic enthalpy head (i.e., the enthalpy rise along constant entropy lines), which is a critical parameter required to accurately design and performance test compressors, limited public domain data are available for equation of state validation. In this paper, a method and test apparatus is described to measure compression enthalpy rise directly. In this apparatus, a test gas is compressed using a fast acting piston inside an adiabatic autoclave. Test results are then corrected using calibration efficiencies from a known reference gas compression process at a similar Reynolds number. The paper describes the test apparatus, calibration, measurement methodology, and test results for one complex hydrocarbon gas composition at elevated temperatures and pressures. An uncertainty analysis of the new measurement method is also presented and results are compared to several equations of state. The results show that commonly used equations of state significantly underpredicted the compression enthalpy rise for the test gas case by more than 6%.

  • Process Control for Compression Systems

    by Rainer Kurz, Klaus Brun

    This paper discusses the interaction between a centrifugal compressor and the process, and as a result, the control requirements for centrifugal compressor packages. The focus is on variable speed, upstream, and midstream applications. The impact of the interaction between system characteristics and compressor characteristics both under steady-state and transient conditions is explained. Also considered are the concepts to optimize and control the units. Special attention is given to the issue of surge avoidance. Additionally, the impact of the process and how the process dynamics interact with the compressor is analyzed, categorized, and explained.


  • Measurement and Prediction of Centrifugal Compressor Axial Forces During Surge—Part II: Dynamic Surge Model

    by Enrico Munari, Mirko Morini, Michele Pinelli, Klaus Brun, Sarah Simons, Rainer Kurz

    The force acting on centrifugal compressors is an important parameter to be considered throughout the operating life of these turbomachines. When the compressor is operating in surge conditions, these forces can become highly dangerous for the mechanical and aerodynamic structures. This instability is usually avoided in industrial applications, but the antisurge system may not react in time when emergency shutdowns or power failures take place. During these rapid transients, surge can develop, generating unsteady forces which can harm the close clearance components of the compressor. Therefore, the capability to predict the characteristics and the dynamics of these surge forces would allow the estimation of the off-design fatigue cycles produced on these components by surge. Currently, no validated method exists to predict the frequency and amplitude of the surge forces and determine the potential damage of these components. In this paper, a lumped parameter model, developed by using the bond graph approach to predict the dynamic surge fluid-dynamic oscillations, is presented. The model requires the geometry and the steady-state performance maps of the compressor as inputs, together with the piping system configuration characteristics. The simulator is provided with a supplementary tool to estimate the axial force frequency and amplitude, taking into consideration all the contributions to the axial fluid-dynamic thrust, the stiffness-damping of the thrust bearing, and the mass of the rotor. The model was tuned and validated using the test case axial force data from the Southwest Research Institute (SWRI) facility. The model has shown good agreement with the experimental results which implies that it can offer significant information about the severity of a surge event and the quantification of the machine performance losses together with possible damage to the close clearance components. This study is a first important step that can lead to schedule optimization for maintenance and repair activities.


  • Measurement and Prediction of Centrifugal Compressor Axial Forces During Surge—Part I: Surge Force Measurements

    by Klaus Brun, Sarah Simons, Rainer Kurz, Enrico Munari, Mirko Morini, Michele Pinelli

    Centrifugal compressor impellers and shafts are subject to severe fluctuating axial and radial forces when operating in surge. These forces can cause severe damage to the close clearance components of a centrifugal compressor such as the thrust and radial bearings, interstage and dry gas seals, and balance piston. Being able to accurately quantify the cyclic surge forces on the close clearance components of the compressor allows the user to determine whether an accidental surge event, or emergency shutdown (ESD) transient, has caused damage requiring inspection, repair, or part replacement. For the test, a 700 hp (∼520 kW) industrial air centrifugal compressor was operated in surge at speeds ranging from 7000 to 13,000 rpm and pressure ratios from 1.2 to 1.8. The axial surge forces were directly measured using axial load cells on the thrust bearings. Suction and discharge pressures, proximity probe axial shaft position, flows, and temperatures were also measured. Time domain and frequency plots of axial vibration and dynamic pulsations showed the impact of the operating conditions on surge force amplitudes and frequencies. A surge severity coefficient was also derived as a simple screening tool to evaluate the magnitude of potential damage to a compressor during surge.


  • Process Control for Compression Systems

    by Rainer Kurz, Klaus Brun

    The paper discusses the interaction between a centrifugal compressor and the process, and as a result, the control requirements for centrifugal compressor packages. The focus is on variable speed, upstream and midstream applications. The impact of the interaction between system characteristics and compressor characteristics, both under steady state and transient conditions is explained. Also considered are concepts to optimize and control the units. Special attention is given to the issue of surge avoidance. Additionally, the impact of the process and how the process dynamics interact with the compressor is analyzed, categorized, and explained.


  • The Impact of Reciprocating Compressor Pulsations on the Surge Margin of Centrifugal Compressors

    by Klaus Brun, Sarah Simons, Rainer Kurz

    Pressure pulsations into a centrifugal compressor can move its operating point into surge. This is concerning in pipeline stations where centrifugal compressors operate in series/parallel with reciprocating compressors. Sparks (1983, “On the Transient Interaction of Centrifugal Compressors and Their Piping Systems,” ASME Paper No. 83-GT-236); Kurz et al. (2006, “Pulsations in Centrifugal Compressor Installations,” ASME Paper No. GT2006-90700); and Brun et al. (2014, “Impact of the Piping Impedance and Acoustic Characteristics on Centrifugal Compressor Surge and Operating Range,” ASME J. Eng. Turbines Power, 137(3), p. 032603) provided predictions on the impact of periodic pressure pulsation on the behavior of a centrifugal compressor. This interaction is known as the “compressor dynamic response” (CDR) theory. Although the CDR describes the impact of the nearby piping system on the compressor surge and pulsation amplification, it has limited usefulness as a quantitative analysis tool, due to the lack of prediction tools and test data for comparison. Testing of compressor mixed operation was performed in an air loop to quantify the impact of periodic pressure pulsation from a reciprocating compressor on the surge margin (SM) of a centrifugal compressor. This data was utilized to validate predictions from Sparks’ CDR theory and Brun’s numerical approach. A 50 hp single-stage, double-acting reciprocating compressor provided inlet pulsations into a two-stage 700 hp centrifugal compressor. Tests were performed over a range of pulsation excitation amplitudes, frequencies, and pipe geometry variations to determine the impact of piping impedance and resonance responses. Results provided clear evidence that pulsations can reduce the surge margin of centrifugal compressors and that geometry of the piping system immediately upstream and downstream of a centrifugal compressor will have an impact on the surge margin reduction. Surge margin reductions of over 30% were observed for high centrifugal compressor inlet suction pulsation.


  • Experimental Evaluation of Compressor Blade Fouling

    by Rainer Kurz, Grant Musgrove, Klaus Brun

    Fouling of compressor blades is an important mechanism leading to performance deterioration in gas turbines over time. Experimental and simulation data are available for the impact of specified amounts of fouling on the performance as well as the amount of foulants entering the engine for defined air filtration systems and ambient conditions. This study provides experimental data on the amount of foulants in the air that actually stick to a blade surface for different conditions. Quantitative results both indicate the amount of dust as well as the distribution of dust on the airfoil, for a dry airfoil, and also the airfoils that were wet from ingested water, in addition to, different types of oil. The retention patterns are correlated with the boundary layer shear stress. The tests show the higher dust retention from wet surfaces compared to dry surfaces. They also provide information about the behavior of the particles after they impact on the blade surface, showing for a certain amount of wet film thickness, the shear forces actually wash the dust downstream and off the airfoil. Further, the effect of particle agglomeration of particles to form larger clusters was observed, which would explain the disproportional impact of very small particles on boundary layer losses.