Sang H. Choi

Sang H. Choi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sang H. Choi has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Electrostatic Power (ESP) Generator and Lunar Dust Mitigater

    by Sang H., Robert W

    Constant bombardment of electrons and protons from the solar wind has charged lunar regolith negatively. The dust is attracted by electrostatic c |

  • Resource Mapping in Extreme Environments

    by Sang H., Robert W

    Measurements within permanently shadowed craters and along steep embankments on extraterrestrial surfaces pose extreme challenges since astronaut |

  • Multipurpose Cassegrain System

    by Sang H., Robert W, Cheol Park, Catharine C

    Ejecta and dust caused during lander plume interactions with the regolith can harm the crew, equipment, and lander. Stabilizing the large landing |

  • Perspective and potential of smart optical materials

    by Sang H Choi, Adam J Duzik, Hyun-Jung Kim, Yeonjoon Park, Jaehwan Kim, Hyun-U Ko, Hyun-Chan Kim, Sungryul Yun, Ki-Uk Kyung

    The increasing requirements of hyperspectral imaging optics, electro/photo-chromic materials, negative refractive index metamaterial optics, and miniaturized optical components from micro-scale to quantum-scale optics have all contributed to new features and advancements in optics technology. Development of multifunctional capable optics has pushed the boundaries of optics into new fields that require new disciplines and materials to maximize the potential benefits. The purpose of this study is to understand and show the fundamental materials and fabrication technology for field-controlled spectrally active optics (referred to as smart optics) that are essential for future industrial, scientific, military, and space applications, such as membrane optics, filters, windows for sensors and probes, telescopes, spectroscopes, cameras, light valves, light switches, and flat-panel displays. The proposed smart optics are based on the Stark and Zeeman effects in materials tailored with quantum dot arrays and thin films made from readily polarizable materials via ferroelectricity or ferromagnetism. Bound excitonic states of organic crystals are also capable of optical adaptability, tunability, and reconfigurability. To show the benefits of smart optics, this paper reviews spectral characteristics of smart optical materials and device technology. Experiments testing the quantum-confined Stark effect, arising from rare earth element doping effects in semiconductors, and applied electric field effects on spectral and refractive index are discussed. Other bulk and dopant materials were also discovered to have the same aspect of shifts in spectrum and refractive index. Other efforts focus on materials for creating field-controlled spectrally smart active optics on a selected spectral range. Surface plasmon polariton transmission of light through apertures is also discussed, along with potential applications. New breakthroughs in micro scale multiple zone plate optics as a micro convex lens are reviewed, along with the newly discovered pseudo-focal point not predicted with conventional optics modeling. Micron-sized solid state beam scanner chips for laser waveguides are reviewed as well.


  • Open Access

    Miniaturized and Wireless Optical Neurotransmitter Sensor for Real-Time Monitoring of Dopamine in the Brain

    by Min H. Kim, Hargsoon Yoon, Sang H. Choi, Fei Zhao, Jongsung Kim, Kyo D. Song, Uhn Lee

    Real-time monitoring of extracellular neurotransmitter concentration offers great benefits for diagnosis and treatment of neurological disorders and diseases. This paper presents the study design and results of a miniaturized and wireless optical neurotransmitter sensor (MWONS) for real-time monitoring of brain dopamine concentration. MWONS is based on fluorescent sensing principles and comprises a microspectrometer unit, a microcontroller for data acquisition, and a Bluetooth wireless network for real-time monitoring. MWONS has a custom-designed application software that controls the operation parameters for excitation light sources, data acquisition, and signal processing. MWONS successfully demonstrated a measurement capability with a limit of detection down to a 100 nanomole dopamine concentration, and high selectivity to ascorbic acid (90:1) and uric acid (36:1).


  • Near field effects of millimeter-wave power transmission for medical applications

    by Hargsoon Yoon, Kyo D. Song, Kunik Lee, Jaehwan Kim, Sang H. Choi

    An integration of micro devices system and wireless power transmission (WPT) technology offers a great potential to revolutionize current health care devices. The system integration of wireless power transmission devices with smart microsensors is crucial for replacing a power storage devices and miniaturizing wireless biomedical systems. Our research goal is to replace battery power supply with an implantable millimeter-wave rectenna. Recently, a hat system with a small millimeter-wave antenna which can feed millimeter-wave power to thin-film rectenna array embedding Schottky diodes was introduced for neural sensing and stimulation applications. In order to prove the design concept and investigate wireless power coupling efficiency under the system design, near-field wireless power transmission was studied in terms of wave frequency and distance. Also, in this paper, we will present the influence of biological objects to the wireless power transmission, simulating the experimental conditions of human objects for future medical applications.


  • Perspective in Nanoneural Electronic Implants With Wireless Power-Feed and Sensory Control

    by Uhn Lee, Kyo D. Song, Yeonjoon Park, Vijay K. Varadan, Sang H. Choi

    New medical device technology is essential for diagnosing, monitoring, and curing wide spectrum of diseases, anomalies, and inflictions. For neural applications, currently available devices are generally limited to either a curing or a probing function. In this paper, we review the technology requirements for a new neural probe and cure device technology currently under development. The concept of the probe-pin device that integrates the probes for neurochemistry, neuroelectricity, temperature, and pressure into a single embodiment with a wireless power transmission was designed for the purpose of deep brain feedback stimulation (DBFS) with in situ neural monitoring. The probe considered for monitoring neurochemistry is a microspectrometer. The feature and size of the microspectrometer are defined for the DBFS device. Two types of wireless power transmission technology were studied for the DBFS device operation. The test results of pig skin showed that both power transmission technologies demonstrated the feasibility of power feed through human tissue.


  • Cobalt oxide hollow nanoparticles derived by bio-templating

    by Jae-Woo Kim, Sang H. Choi, Peter T. Lillehei, Sang-Hyon Chu, Glen C. King, Gerald D. Watt

    We present here the first fabrication of hollow cobalt oxide nanoparticles produced by a protein-regulated site-specific reconstitution process in aqueous solution and describe the metal growth mechanism in the ferritin interior.


  • Mechanical and electrical properties of electroactive papers and its potential application

    by Jaehwan Kim, Woochul Jung, William Craft, John Shelton, Kyo D. Song, Sang H. Choi

    This paper focuses on the mechanical and electrical characteristics of electro-active paper (EAPap) as a bio-inspired actuator and the potential use of these actuators in some specific applications. EAPap can undergo a large bending displacement at a relatively low voltage under low power consumption in dry conditions. EAPap samples as tested are made from chemically treated cellulose paper. When an electrical field is applied to the electrodes, a “bending displacement” is produced as the material tends to deform into a constant curvature coil. However, the EAPap is a complex anisotropic material, which has not been extensively characterized and additional basic and design testing is required before developing application devices from EAPap. Mechanical properties of selected EAPap materials along three material axes are addressed. EAPap material exhibits two distinct elastic constants connected by a bifurcation point along the stress strain diagram. The initial Young’s modulus of EAPap is in the range of 5-8GPa, -- quite high compared to other polymer materials. The thermo-mechanical analysis of EAPap is investigated to determine such factors as the degree of dimensional change due to dehydration and the maximum use temperature. Fatigue test identifies critical properties of this under-analyzed class of materials to provide a measure of its fatigue capabilities. The Electrical impedance analysis and dielectric property measurement with frequency are also important information that allows us to characterize the electrical behavior of EAPap. The performance of Eapap is measured in terms of tip displacement, blocking force and electrical power consumption. Through this series of tests, better understanding of the EAPap materials is obtained to researchers and designers interested in smart materials and EAP areas.


  • Rectenna performance under a 200-W amplifier microwave

    by Kyo D. Song, Sang H. Choi, Walter T. Golembiewski, Kevin Henderson, Glen C. King

    The concept of microwave driven smart material actuators is envisioned as the best option to alleviate the complexity associated with hard wired control circuitry for applications such as membrane actuators, insect-like flying objects, or micro-aero-vehicles. Accordingly, rectenna technology was adopted to convert power from microwave to DC and run actuator devices. Previous experimental results showed that 230 VDC output was obtained from a 6 x 6 rectenna array at a far-field exposure (1.8 meters away) with an x-band input power of 20 watts. This result showed the feasibility of using microwaves to power feed and control smart actuators. We have tested a 6 x 6 JPL array patch rectenna which was designed to generate theoretical voltages up to 540 volts. The test result indicated that the performance degradation of Shottky barrier diodes on the rectenna array caused the output voltage to drop. Thus, an estimation of output voltage was made to show the performance beyond the previous measurement by extrapolating and correlating the measured data with a 200 W TWT amplifier in a reverse process. The estimated peak output voltage was 515 volts. In this experiment, due to the degradation of the rectenna performance, we had to measure the output performance based on comparison of the previous result of the rectenna output of a 20W amplifier with the output from the 200 W amplifier. For the real applications, the degradation of Schottky diodes will be a critical issue to be resolved in the fabrication process.