Hargsoon Yoon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hargsoon Yoon has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Kyo Young Song
Center for Materials Research, Norfolk State University, Norfolk, VA 23504, USA
2 shared publications - Sang H. Choi
NASA Langley Research Ctr. (United States)
2 shared publications Courtney S. Smith
Department of Engineering, Norfolk State University, 700 Park Avenue, Norfolk, VA 23504
1 shared publication- Fei Zhao
Department of Chemical and Biological Engineering, Gachon University, Seongnam 13120, Korea
1 shared publication - Guoliang Huang
Department of Systems Engineering, University of Arkansas at Little Rock, Little Rock, AR 72204
1 shared publication - Jaehwan Kim
Creative Research Center for Nanocellulose Future Composites, Inha University, Incheon, Republic of Korea
1 shared publication
Latest Publications
- Open Access
Miniaturized and Wireless Optical Neurotransmitter Sensor for Real-Time Monitoring of Dopamine in the Brain
Real-time monitoring of extracellular neurotransmitter concentration offers great benefits for diagnosis and treatment of neurological disorders and diseases. This paper presents the study design and results of a miniaturized and wireless optical neurotransmitter sensor (MWONS) for real-time monitoring of brain dopamine concentration. MWONS is based on fluorescent sensing principles and comprises a microspectrometer unit, a microcontroller for data acquisition, and a Bluetooth wireless network for real-time monitoring. MWONS has a custom-designed application software that controls the operation parameters for excitation light sources, data acquisition, and signal processing. MWONS successfully demonstrated a measurement capability with a limit of detection down to a 100 nanomole dopamine concentration, and high selectivity to ascorbic acid (90:1) and uric acid (36:1).
Open AccessMiniaturized and Wireless Optical Neurotransmitter Sensor for Real-Time Monitoring of Dopamine in the Brain
Real-time monitoring of extracellular neurotransmitter concentration offers great benefits for diagnosis and treatment of neurological disorders and diseases. This paper presents the study design and results of a miniaturized and wireless optical neurotransmitter sensor (MWONS) for real-time monitoring of brain dopamine concentration. MWONS is based on fluorescent sensing principles and comprises a microspectrometer unit, a microcontroller for data acquisition, and a Bluetooth wireless network for real-time monitoring. MWONS has a custom-designed application software that controls the operation parameters for excitation light sources, data acquisition, and signal processing. MWONS successfully demonstrated a measurement capability with a limit of detection down to a 100 nanomole dopamine concentration, and high selectivity to ascorbic acid (90:1) and uric acid (36:1).
- Open Access
- 16 June 2016
- Published by MDPI AG in Biosensors
- Vol. 6 (2) , 27
Computational Assessment of Neural Probe and Brain Tissue Interface under Transient Motion
The functional longevity of a neural probe is dependent upon its ability to minimize injury risk during the insertion and recording period in vivo, which could be related to motion-related strain between the probe and surrounding tissue. A series of finite element analyses was conducted to study the extent of the strain induced within the brain in an area around a neural probe. This study focuses on the transient behavior of neural probe and brain tissue interface with a viscoelastic model. Different stages of the interface from initial insertion of neural probe to full bonding of the probe by astro-glial sheath formation are simulated utilizing analytical tools to investigate the effects of relative motion between the neural probe and the brain while friction coefficients and kinematic frequencies are varied. The analyses can provide an in-depth look at the quantitative benefits behind using soft materials for neural probes.
- 16 June 2016
- Published by MDPI AG in Biosensors
- Vol. 6 (2) , 27
Open AccessComputational Assessment of Neural Probe and Brain Tissue Interface under Transient Motion
The functional longevity of a neural probe is dependent upon its ability to minimize injury risk during the insertion and recording period in vivo, which could be related to motion-related strain between the probe and surrounding tissue. A series of finite element analyses was conducted to study the extent of the strain induced within the brain in an area around a neural probe. This study focuses on the transient behavior of neural probe and brain tissue interface with a viscoelastic model. Different stages of the interface from initial insertion of neural probe to full bonding of the probe by astro-glial sheath formation are simulated utilizing analytical tools to investigate the effects of relative motion between the neural probe and the brain while friction coefficients and kinematic frequencies are varied. The analyses can provide an in-depth look at the quantitative benefits behind using soft materials for neural probes.
- 1 August 2011
- Published by Wiley in Journal of Nanotechnology in Engineering and Medicine
- Vol. 2 (3) , 031001
Biomechanical Strain Analysis at the Interface of Brain and Nanowire Electrodes on a Neural Probe
The viability of neural probes with microelectrodes for neural recording and stimulation in the brain is important for the development of neuroprosthetic devices. Vertically aligned nanowire microelectrode arrays can significantly enhance the capabilities of neuroprosthetic devices. However, when they are implanted into the brain, micromotion and mechanical stress around the neural probe may cause tissue damage and reactive immune response, which may degrade recording signals from neurons. In this research, a finite-element model of the nanowire microelectrode and brain tissue was developed. A rigid body method was provided, and the simulation efficiency was significantly increased. The interface between the microelectrode and brain tissue was modeled by contact elements. Brain micromotion was mimicked by applying a displacement load to the electrode and fixing the boundaries of the brain region. It was observed that the vertically aligned nanostructures on the electrode of the neural probe do increase the cellular sheath area. The strain field distributions under various physical coupling cases at the interface were analyzed along with different loading effects on the neural electrode.
- 1 August 2011
- Published by Wiley in Journal of Nanotechnology in Engineering and Medicine
- Vol. 2 (3) , 031001
Biomechanical Strain Analysis at the Interface of Brain and Nanowire Electrodes on a Neural Probe
The viability of neural probes with microelectrodes for neural recording and stimulation in the brain is important for the development of neuroprosthetic devices. Vertically aligned nanowire microelectrode arrays can significantly enhance the capabilities of neuroprosthetic devices. However, when they are implanted into the brain, micromotion and mechanical stress around the neural probe may cause tissue damage and reactive immune response, which may degrade recording signals from neurons. In this research, a finite-element model of the nanowire microelectrode and brain tissue was developed. A rigid body method was provided, and the simulation efficiency was significantly increased. The interface between the microelectrode and brain tissue was modeled by contact elements. Brain micromotion was mimicked by applying a displacement load to the electrode and fixing the boundaries of the brain region. It was observed that the vertically aligned nanostructures on the electrode of the neural probe do increase the cellular sheath area. The strain field distributions under various physical coupling cases at the interface were analyzed along with different loading effects on the neural electrode.
- 24 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7980, 798012
Near field effects of millimeter-wave power transmission for medical applications
An integration of micro devices system and wireless power transmission (WPT) technology offers a great potential to revolutionize current health care devices. The system integration of wireless power transmission devices with smart microsensors is crucial for replacing a power storage devices and miniaturizing wireless biomedical systems. Our research goal is to replace battery power supply with an implantable millimeter-wave rectenna. Recently, a hat system with a small millimeter-wave antenna which can feed millimeter-wave power to thin-film rectenna array embedding Schottky diodes was introduced for neural sensing and stimulation applications. In order to prove the design concept and investigate wireless power coupling efficiency under the system design, near-field wireless power transmission was studied in terms of wave frequency and distance. Also, in this paper, we will present the influence of biological objects to the wireless power transmission, simulating the experimental conditions of human objects for future medical applications.
- 24 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7980, 798012
Near field effects of millimeter-wave power transmission for medical applications
An integration of micro devices system and wireless power transmission (WPT) technology offers a great potential to revolutionize current health care devices. The system integration of wireless power transmission devices with smart microsensors is crucial for replacing a power storage devices and miniaturizing wireless biomedical systems. Our research goal is to replace battery power supply with an implantable millimeter-wave rectenna. Recently, a hat system with a small millimeter-wave antenna which can feed millimeter-wave power to thin-film rectenna array embedding Schottky diodes was introduced for neural sensing and stimulation applications. In order to prove the design concept and investigate wireless power coupling efficiency under the system design, near-field wireless power transmission was studied in terms of wave frequency and distance. Also, in this paper, we will present the influence of biological objects to the wireless power transmission, simulating the experimental conditions of human objects for future medical applications.