Gerhard Hindricks
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gerhard Hindricks has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
- Arash Arya
Department of Electrophysiology, Heart Center, University of Leipzig, Leipzig, Germany
8 shared publications - Christopher Piorkowski
Department of Electrophysiology, University of Leipzig, Heart Center, Leipzig, Germany
7 shared publications Daniela Husser
6 shared publications- Philipp Sommer
Universität Leipzig – Herzzentrum
6 shared publications - Andreas Bollmann
Department of Cardiology, Lund University, Lund, Sweden
5 shared publications - Jelena Kornej
Boston University's and National Heart, Lung, and Blood Institute's Framingham Heart Study Framingham, MA United States
5 shared publications
Latest Publications
- Open Access
- 3 January 2016
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 37 (7) , 587-593
The year in cardiology 2015: arrhythmias and device therapy
The year 2015 was once more filled with exciting and important novel developments in the field of invasive electrophysiology and implantable cardiac devices. These include technical innovation, novel molecular and cellular insights, and presentation of large randomized clinical trials as well as important ‘real-world’ registries. In addition, several new guidelines surfaced in 2015, including those for the treatment of ventricular arrhythmias and prevention of sudden cardiac death. It is virtually impossible to cover all novel developments that would merit discussion in this type of overview; as a result, the authors had to make a selection, focusing on several important developments with direct implications for daily clinical practice.
- 3 January 2016
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 37 (7) , 587-593
Open AccessThe year in cardiology 2015: arrhythmias and device therapy
The year 2015 was once more filled with exciting and important novel developments in the field of invasive electrophysiology and implantable cardiac devices. These include technical innovation, novel molecular and cellular insights, and presentation of large randomized clinical trials as well as important ‘real-world’ registries. In addition, several new guidelines surfaced in 2015, including those for the treatment of ventricular arrhythmias and prevention of sudden cardiac death. It is virtually impossible to cover all novel developments that would merit discussion in this type of overview; as a result, the authors had to make a selection, focusing on several important developments with direct implications for daily clinical practice.
- Open Access
- 8 November 2015
- Published by Elsevier in The Lancet
- Vol. 387 (10017) , 408-410
Pulmonary pressure, telemedicine, and heart failure therapy
- 8 November 2015
- Published by Elsevier in The Lancet
- Vol. 387 (10017) , 408-410
Open AccessPulmonary pressure, telemedicine, and heart failure therapy
- 1 January 2015
- Published by Elsevier in International Journal of Cardiology
- Vol. 179, 493-494
NT-proBNP in “low risk” patients with atrial fibrillation
- 1 January 2015
- Published by Elsevier in International Journal of Cardiology
- Vol. 179, 493-494
NT-proBNP in “low risk” patients with atrial fibrillation
- Top Cited Papers
- 1 August 2014
- Published by Elsevier in The Lancet
- Vol. 384 (9943) , 583-590
Implant-based multiparameter telemonitoring of patients with heart failure (IN-TIME): a randomised controlled trial
- 1 August 2014
- Published by Elsevier in The Lancet
- Vol. 384 (9943) , 583-590
Top Cited PapersImplant-based multiparameter telemonitoring of patients with heart failure (IN-TIME): a randomised controlled trial
- 1 May 2013
- Published by Elsevier in The American Journal of Cardiology
- Vol. 111 (9) , 1311-1314
Usefulness of Dronedarone in Patients With Atrial Arrhythmias
- 1 May 2013
- Published by Elsevier in The American Journal of Cardiology
- Vol. 111 (9) , 1311-1314
Usefulness of Dronedarone in Patients With Atrial Arrhythmias
- Open Access
- 2 August 2012
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 15 (4) , 578-581
Initial experience in ablation of typical atrial flutter using a novel three-dimensional catheter tracking system
Three-dimensional (3D) mapping has been established for clinical routine in an interventional electrophysiology (EP). Recently, a novel sensor-based 3D catheter tracking system has been introduced integrating 3D non-fluoroscopic catheter navigation into the environment of pre-recorded 2D fluoroscopy [MediGuide™ Technology (MG)]. We are reporting on the first clinical experience for ablation of typical atrial flutter. First we aimed to demonstrate safety and feasibility of this new technique. Secondly, procedural aspects such as effectiveness, procedure, and fluoroscopy time should be evaluated. Ten consecutive patients (100% male, age 68 ± 8 years) were ablated using MG technology. Two steerable diagnostic EP catheters (MediGuide Enabled Livewire™ Catheter, SJM) were used for coronary sinus cannulation and anatomical cavo-tricuspidal isthmus (CTI) reconstruction within the EnSite NavX™ System (NavX). Ablation was performed with a conventional 8 mm tip ablation catheter (IBI, SJM). In all 10 patients both sensor-equipped MG catheters could be tracked non-fluoroscopically. Successful anatomical CTI reconstruction was performed and complete isthmus block was documented after the ablation. Total procedure duration was comparable with conventional procedures (55 ± 8 min). Usage of the MG tracking system resulted in a fluoroscopy time of 2.5 ± 2 min. No adverse events occurred during the procedures. For the first clinical application of the MG technology in an interventional electrophysiology we found a stable system enabling excellent 3D orientation for spatial catheter positioning on the basis of underlying pre-recorded cine loops. Clinically, the MG technology allowed successful procedures with short fluoroscopy times, even though a sensor-equipped ablation catheter was not yet available for use in the study.
- 2 August 2012
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 15 (4) , 578-581
Open AccessInitial experience in ablation of typical atrial flutter using a novel three-dimensional catheter tracking system
Three-dimensional (3D) mapping has been established for clinical routine in an interventional electrophysiology (EP). Recently, a novel sensor-based 3D catheter tracking system has been introduced integrating 3D non-fluoroscopic catheter navigation into the environment of pre-recorded 2D fluoroscopy [MediGuide™ Technology (MG)]. We are reporting on the first clinical experience for ablation of typical atrial flutter. First we aimed to demonstrate safety and feasibility of this new technique. Secondly, procedural aspects such as effectiveness, procedure, and fluoroscopy time should be evaluated. Ten consecutive patients (100% male, age 68 ± 8 years) were ablated using MG technology. Two steerable diagnostic EP catheters (MediGuide Enabled Livewire™ Catheter, SJM) were used for coronary sinus cannulation and anatomical cavo-tricuspidal isthmus (CTI) reconstruction within the EnSite NavX™ System (NavX). Ablation was performed with a conventional 8 mm tip ablation catheter (IBI, SJM). In all 10 patients both sensor-equipped MG catheters could be tracked non-fluoroscopically. Successful anatomical CTI reconstruction was performed and complete isthmus block was documented after the ablation. Total procedure duration was comparable with conventional procedures (55 ± 8 min). Usage of the MG tracking system resulted in a fluoroscopy time of 2.5 ± 2 min. No adverse events occurred during the procedures. For the first clinical application of the MG technology in an interventional electrophysiology we found a stable system enabling excellent 3D orientation for spatial catheter positioning on the basis of underlying pre-recorded cine loops. Clinically, the MG technology allowed successful procedures with short fluoroscopy times, even though a sensor-equipped ablation catheter was not yet available for use in the study.