Christiane Waller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christiane Waller has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Axel Haase
Technische Universität München, Munich, Germany
3 shared publications Georg Ertl
Medizinische Klinik und Poliklinik I, Universität Würzburg, Germany
3 shared publicationsKarl-Heinz Hiller
Physikalisches Institut, Universität Würzburg, Germany
3 shared publicationsEberhard Rommel
2 shared publications- Frank Wiesmann
Medizinische Universitätsklinik Würzburg, Germany
2 shared publications - Jörg U.G. Streif
Physikalisches Institut, Lehrstuhl für Experimentelle Physik V (Biophysik), Universität Würzburg, Am Hubland, Würzburg, Germany
2 shared publications
Latest Publications
- 1 January 2008
- Published by Elsevier in Microvascular Research
- Vol. 75 (1) , 104-111
Functional mechanisms of myocardial microcirculation in left ventricular hypertrophy
- 1 January 2008
- Published by Elsevier in Microvascular Research
- Vol. 75 (1) , 104-111
Functional mechanisms of myocardial microcirculation in left ventricular hypertrophy
- Open Access
- 1 June 2005
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 288 (6) , H2588-H2593
Impaired resting perfusion in viable myocardium distal to chronic coronary stenosis in rats
Chronic coronary artery stenosis results in patchy necrosis in the dependent myocardium and impairs global and regional left ventricular (LV) function in rats in vivo. The aim of the present study was to compare regional myocardial blood flow (RMBF) and function (F) in poststenotic myocardium by using magnetic resonance imaging (MRI) and to compare MRI blood flow changes to histological alterations to assess whether RMBF in the viable poststenotic tissue remains normal. MRI was performed in 11 anesthetized Wistar rats with 2-wk stenosis of the left coronary artery. Postmortem, the extent of fibrotic tissue was quantified. Poststenotic RMBF was significantly reduced to 2.21 ± 0.30 ml·g−1·min−1 compared with RMBF in the remote myocardium (4.05 ± 0.50 ml·g−1·min−1). A significant relationship between the poststenotic RMBF (%remote area) and the poststenotic F (%remote myocardium) was calculated ( r = 0.61, P < 0.05). Assuming perfusion in scar tissue to be 32 ± 5% of perfusion of remote myocardium, as measured in five additional rats, and that in remote myocardium to be 114 ± 25% of that in normal myocardium, as assessed in five sham rats, the calculated perfusion in partially fibrotic tissue samples (35.7 ± 5.2% of analyzed area) was 2.88 ± 0.18 ml·g−1·min−1, whereas measured MRI perfusion was only 1.86 ± 0.24 ml·g−1·min−1 ( P < 0.05). These results indicate that resting perfusion in viable poststenotic myocardium is moderately reduced. Alterations in global and regional LV function are therefore secondary to both patchy fibrosis and reduced resting perfusion.
- 1 June 2005
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 288 (6) , H2588-H2593
Open AccessImpaired resting perfusion in viable myocardium distal to chronic coronary stenosis in rats
Chronic coronary artery stenosis results in patchy necrosis in the dependent myocardium and impairs global and regional left ventricular (LV) function in rats in vivo. The aim of the present study was to compare regional myocardial blood flow (RMBF) and function (F) in poststenotic myocardium by using magnetic resonance imaging (MRI) and to compare MRI blood flow changes to histological alterations to assess whether RMBF in the viable poststenotic tissue remains normal. MRI was performed in 11 anesthetized Wistar rats with 2-wk stenosis of the left coronary artery. Postmortem, the extent of fibrotic tissue was quantified. Poststenotic RMBF was significantly reduced to 2.21 ± 0.30 ml·g−1·min−1 compared with RMBF in the remote myocardium (4.05 ± 0.50 ml·g−1·min−1). A significant relationship between the poststenotic RMBF (%remote area) and the poststenotic F (%remote myocardium) was calculated ( r = 0.61, P < 0.05). Assuming perfusion in scar tissue to be 32 ± 5% of perfusion of remote myocardium, as measured in five additional rats, and that in remote myocardium to be 114 ± 25% of that in normal myocardium, as assessed in five sham rats, the calculated perfusion in partially fibrotic tissue samples (35.7 ± 5.2% of analyzed area) was 2.88 ± 0.18 ml·g−1·min−1, whereas measured MRI perfusion was only 1.86 ± 0.24 ml·g−1·min−1 ( P < 0.05). These results indicate that resting perfusion in viable poststenotic myocardium is moderately reduced. Alterations in global and regional LV function are therefore secondary to both patchy fibrosis and reduced resting perfusion.
- 1 January 2005
- Published by Wiley in Microcirculation
- Vol. 12 (4) , 339-347
Noninvasive Imaging of Angiogenesis Inhibition Following Nitric Oxide Synthase Blockade in the Ischemic Rat Heart in Vivo
Objective: Nitric oxide synthase inhibition has anti‐angiogenic properties. Magnetic resonance (MR) imaging was used to image the functional significance of these microvascular changes in a rat model of chronic ischemic myocardium in vivo. Methods: The authors quantitatively determined myocardial perfusion and regional blood volume, left ventricular geometry, and function using MR imaging. Animals received either L‐NAME + hydralazine or no treatment and were investigated 1 and 2 weeks after induction of coronary artery stenosis or sham operation at rest and during vasodilatation. Double‐labeling immunohistochemistry was used to visualize angiogenesis and to compare with data obtained by MR imaging. Results: Left ventricular mass and end‐diastolic volumes were comparable in both groups 2 weeks after treatment. However, basal and maximum perfusion in animals with L‐NAME + hydralazine treatment were reduced compared to animals not treated (p < .05). Basal regional blood volume remained constant in all groups, whereas maximum regional blood volume was reduced by L‐NAME + hydralazine (p < .05). Endothelial cell proliferation, a direct marker for angiogenesis, was reduced by L‐NAME + hydralazine (p < .01). Conclusions: MR imaging allows noninvasive quantification of functional microcirculation and angiogenesis in the rat heart in vivo. Nitric oxide synthase blockade results in changes in functional microcirculation and in an inhibition of angiogenesis in both ischemic and nonischemic myocardial tissue.
- 1 January 2005
- Published by Wiley in Microcirculation
- Vol. 12 (4) , 339-347
Noninvasive Imaging of Angiogenesis Inhibition Following Nitric Oxide Synthase Blockade in the Ischemic Rat Heart in Vivo
Objective: Nitric oxide synthase inhibition has anti‐angiogenic properties. Magnetic resonance (MR) imaging was used to image the functional significance of these microvascular changes in a rat model of chronic ischemic myocardium in vivo. Methods: The authors quantitatively determined myocardial perfusion and regional blood volume, left ventricular geometry, and function using MR imaging. Animals received either L‐NAME + hydralazine or no treatment and were investigated 1 and 2 weeks after induction of coronary artery stenosis or sham operation at rest and during vasodilatation. Double‐labeling immunohistochemistry was used to visualize angiogenesis and to compare with data obtained by MR imaging. Results: Left ventricular mass and end‐diastolic volumes were comparable in both groups 2 weeks after treatment. However, basal and maximum perfusion in animals with L‐NAME + hydralazine treatment were reduced compared to animals not treated (p < .05). Basal regional blood volume remained constant in all groups, whereas maximum regional blood volume was reduced by L‐NAME + hydralazine (p < .05). Endothelial cell proliferation, a direct marker for angiogenesis, was reduced by L‐NAME + hydralazine (p < .01). Conclusions: MR imaging allows noninvasive quantification of functional microcirculation and angiogenesis in the rat heart in vivo. Nitric oxide synthase blockade results in changes in functional microcirculation and in an inhibition of angiogenesis in both ischemic and nonischemic myocardial tissue.
- 1 January 2004
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 6 (2) , 165-168
Adverse effects of direct current cardioversion on cardiac pacemakers and electrodes
Use of pacing in sick sinus syndrome and recent developments in pacemaker therapy for intermittent atrial fibrillation raise the question of whether external electrical cardioversion should be used for termination of atrial fibrillation. This paper analyzes three cases of pacemaker and/or electrode dysfunction appearing after direct current (DC) cardioversion for termination of atrial fibrillation. Despite similar conditions during cardioversion in all cases, different dysfunctions reflecting damage to the pulse generator and/or a rise of the stimulation threshold in both, atrial and ventricular leads, have been observed. The possible mechanisms for these effects are discussed and recommendations for the management of cardioversion in patients with permanent pacemaker systems are given.
- 1 January 2004
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 6 (2) , 165-168
Adverse effects of direct current cardioversion on cardiac pacemakers and electrodes
Use of pacing in sick sinus syndrome and recent developments in pacemaker therapy for intermittent atrial fibrillation raise the question of whether external electrical cardioversion should be used for termination of atrial fibrillation. This paper analyzes three cases of pacemaker and/or electrode dysfunction appearing after direct current (DC) cardioversion for termination of atrial fibrillation. Despite similar conditions during cardioversion in all cases, different dysfunctions reflecting damage to the pulse generator and/or a rise of the stimulation threshold in both, atrial and ventricular leads, have been observed. The possible mechanisms for these effects are discussed and recommendations for the management of cardioversion in patients with permanent pacemaker systems are given.
- 1 November 2003
- Published by Elsevier in Microvascular Research
- Vol. 66 (3) , 173-182
Microvascular adaptation to coronary stenosis in the rat heart in vivo: a serial magnetic resonance imaging study
- 1 November 2003
- Published by Elsevier in Microvascular Research
- Vol. 66 (3) , 173-182
Microvascular adaptation to coronary stenosis in the rat heart in vivo: a serial magnetic resonance imaging study
- Open Access
- 19 September 2003
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 18 (4) , 516-517
Reply
- 19 September 2003
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 18 (4) , 516-517
Open AccessReply
- Open Access
- 23 December 2002
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 17 (1) , 147-152
In vivo assessment of absolute perfusion in the murine skeletal muscle with spin labeling MRI
Purpose To assess absolute perfusion in the skeletal muscle of mice in vivo with spin labeling magnetic resonance imaging (MRI) under normal and stress conditions. Materials and Methods Absolute perfusion in the skeletal muscle of 27 C57BL/6 mice was assessed in vivo non‐invasively by spin labeling MRI at 7.05 T. This technique was based on the acquisition of T1 maps with global and slice‐selective spin inversion in separate acquisitions. T1 mapping was performed by inversion recovery snapshot fast low angle shot imaging. To guarantee proper spin inversion within the whole mouse, a dedicated radiofrequency (RF) coil combination was constructed. A birdcage resonator was used for transmission, while detection of the MRI signal was achieved by a surface coil. Results Basal perfusion in the hindlimbs was determined to be 94 ± 10 mL (100 g · minute)–1 (mean ± standard error of the mean [SEM], N = 27). This value is in good agreement with perfusion values determined by invasive techniques such as microspheres. A subgroup of six animals received a constant dose of 4 mg (kg · minute)–1 of the vasodilator adenosine by an intraperitoneal catheter. In this case, perfusion was significantly increased to 179 ± 56 mL (100 g · minute)–1 (mean ± SEM, N = 6, P < 0.02). Mean basal perfusion in this subgroup was 96 ± 26 mL (100 g · minute)–1. Conclusion Spin labeling MRI is a well‐suited technique for the in vivo assessment of absolute perfusion in the murine skeletal muscle. J. Magn. Reson. Imaging 2003;17:147–152.
- 23 December 2002
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 17 (1) , 147-152
Open AccessIn vivo assessment of absolute perfusion in the murine skeletal muscle with spin labeling MRI
Purpose To assess absolute perfusion in the skeletal muscle of mice in vivo with spin labeling magnetic resonance imaging (MRI) under normal and stress conditions. Materials and Methods Absolute perfusion in the skeletal muscle of 27 C57BL/6 mice was assessed in vivo non‐invasively by spin labeling MRI at 7.05 T. This technique was based on the acquisition of T1 maps with global and slice‐selective spin inversion in separate acquisitions. T1 mapping was performed by inversion recovery snapshot fast low angle shot imaging. To guarantee proper spin inversion within the whole mouse, a dedicated radiofrequency (RF) coil combination was constructed. A birdcage resonator was used for transmission, while detection of the MRI signal was achieved by a surface coil. Results Basal perfusion in the hindlimbs was determined to be 94 ± 10 mL (100 g · minute)–1 (mean ± standard error of the mean [SEM], N = 27). This value is in good agreement with perfusion values determined by invasive techniques such as microspheres. A subgroup of six animals received a constant dose of 4 mg (kg · minute)–1 of the vasodilator adenosine by an intraperitoneal catheter. In this case, perfusion was significantly increased to 179 ± 56 mL (100 g · minute)–1 (mean ± SEM, N = 6, P < 0.02). Mean basal perfusion in this subgroup was 96 ± 26 mL (100 g · minute)–1. Conclusion Spin labeling MRI is a well‐suited technique for the in vivo assessment of absolute perfusion in the murine skeletal muscle. J. Magn. Reson. Imaging 2003;17:147–152.