Jörg U.G. Streif
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jörg U.G. Streif has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Axel Haase
Technische Universität München, Munich, Germany
3 shared publications Eberhard Rommel
3 shared publications- Christiane Waller
Medizinische Universitätsklinik, Würzburg, Germany
2 shared publications - Frank Wiesmann
Medizinische Universitätsklinik Würzburg, Germany
2 shared publications - Karl-Heinz Hiller
Research Center Magnetic-Resonance-Bavaria
2 shared publications - Matthias Nahrendorf
Center for Systems Biology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
2 shared publications
Latest Publications
- Open Access
- 19 September 2003
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 18 (4) , 516-517
Reply
- 19 September 2003
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 18 (4) , 516-517
Open AccessReply
- Open Access
- 21 January 2003
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 49 (2) , 315-321
In vivo time‐resolved quantitative motion mapping of the murine myocardium with phase contrast MRI
Myocardial motion of healthy mice and mice with myocardial infarction was assessed in vivo by phase contrast (PC) cine MRI. The imaging module was a segmented fast low angle shot (FLASH) sequence with velocity compensation in all three gradient directions. To accomplish additional motion encoding, the spin phase was prepared using bipolar gradient pulses, which resulted in a linear dependence between the voxel velocity and spin phase. This method provided accurate quantification of the velocity magnitude and direction of the murine myocardium at a spatial resolution of 234 μm and a temporal resolution of about 10 ms. The acquisition was EKG‐gated and the mice were anesthetized by inhalation of 1.5–4.0 vol.% isoflurane at 1.5 l/min oxygen flow. To validate the MRI measurements, an experiment with a calibrated rotating phantom was performed. Deviations between MR velocity measurements and optical assessment by a light detector were lower than 1.6%. During our study, myocardial motion velocities between 0.4 cm/s and 1.7 cm/s were determined for the healthy murine myocardium across the heart cycle. Areas with myocardial infarction were clearly segmented and showed a motion velocity which was significantly reduced. In conclusion, the method is an accurate technique for the assessment of murine myocardial motion in vivo. Magn Reson Med 49:315–321, 2003.
- 21 January 2003
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 49 (2) , 315-321
Open AccessIn vivo time‐resolved quantitative motion mapping of the murine myocardium with phase contrast MRI
Myocardial motion of healthy mice and mice with myocardial infarction was assessed in vivo by phase contrast (PC) cine MRI. The imaging module was a segmented fast low angle shot (FLASH) sequence with velocity compensation in all three gradient directions. To accomplish additional motion encoding, the spin phase was prepared using bipolar gradient pulses, which resulted in a linear dependence between the voxel velocity and spin phase. This method provided accurate quantification of the velocity magnitude and direction of the murine myocardium at a spatial resolution of 234 μm and a temporal resolution of about 10 ms. The acquisition was EKG‐gated and the mice were anesthetized by inhalation of 1.5–4.0 vol.% isoflurane at 1.5 l/min oxygen flow. To validate the MRI measurements, an experiment with a calibrated rotating phantom was performed. Deviations between MR velocity measurements and optical assessment by a light detector were lower than 1.6%. During our study, myocardial motion velocities between 0.4 cm/s and 1.7 cm/s were determined for the healthy murine myocardium across the heart cycle. Areas with myocardial infarction were clearly segmented and showed a motion velocity which was significantly reduced. In conclusion, the method is an accurate technique for the assessment of murine myocardial motion in vivo. Magn Reson Med 49:315–321, 2003.
- Open Access
- 23 December 2002
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 17 (1) , 147-152
In vivo assessment of absolute perfusion in the murine skeletal muscle with spin labeling MRI
Purpose To assess absolute perfusion in the skeletal muscle of mice in vivo with spin labeling magnetic resonance imaging (MRI) under normal and stress conditions. Materials and Methods Absolute perfusion in the skeletal muscle of 27 C57BL/6 mice was assessed in vivo non‐invasively by spin labeling MRI at 7.05 T. This technique was based on the acquisition of T1 maps with global and slice‐selective spin inversion in separate acquisitions. T1 mapping was performed by inversion recovery snapshot fast low angle shot imaging. To guarantee proper spin inversion within the whole mouse, a dedicated radiofrequency (RF) coil combination was constructed. A birdcage resonator was used for transmission, while detection of the MRI signal was achieved by a surface coil. Results Basal perfusion in the hindlimbs was determined to be 94 ± 10 mL (100 g · minute)–1 (mean ± standard error of the mean [SEM], N = 27). This value is in good agreement with perfusion values determined by invasive techniques such as microspheres. A subgroup of six animals received a constant dose of 4 mg (kg · minute)–1 of the vasodilator adenosine by an intraperitoneal catheter. In this case, perfusion was significantly increased to 179 ± 56 mL (100 g · minute)–1 (mean ± SEM, N = 6, P < 0.02). Mean basal perfusion in this subgroup was 96 ± 26 mL (100 g · minute)–1. Conclusion Spin labeling MRI is a well‐suited technique for the in vivo assessment of absolute perfusion in the murine skeletal muscle. J. Magn. Reson. Imaging 2003;17:147–152.
- 23 December 2002
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 17 (1) , 147-152
Open AccessIn vivo assessment of absolute perfusion in the murine skeletal muscle with spin labeling MRI
Purpose To assess absolute perfusion in the skeletal muscle of mice in vivo with spin labeling magnetic resonance imaging (MRI) under normal and stress conditions. Materials and Methods Absolute perfusion in the skeletal muscle of 27 C57BL/6 mice was assessed in vivo non‐invasively by spin labeling MRI at 7.05 T. This technique was based on the acquisition of T1 maps with global and slice‐selective spin inversion in separate acquisitions. T1 mapping was performed by inversion recovery snapshot fast low angle shot imaging. To guarantee proper spin inversion within the whole mouse, a dedicated radiofrequency (RF) coil combination was constructed. A birdcage resonator was used for transmission, while detection of the MRI signal was achieved by a surface coil. Results Basal perfusion in the hindlimbs was determined to be 94 ± 10 mL (100 g · minute)–1 (mean ± standard error of the mean [SEM], N = 27). This value is in good agreement with perfusion values determined by invasive techniques such as microspheres. A subgroup of six animals received a constant dose of 4 mg (kg · minute)–1 of the vasodilator adenosine by an intraperitoneal catheter. In this case, perfusion was significantly increased to 179 ± 56 mL (100 g · minute)–1 (mean ± SEM, N = 6, P < 0.02). Mean basal perfusion in this subgroup was 96 ± 26 mL (100 g · minute)–1. Conclusion Spin labeling MRI is a well‐suited technique for the in vivo assessment of absolute perfusion in the murine skeletal muscle. J. Magn. Reson. Imaging 2003;17:147–152.