Mohammad Kazem Sharbatdar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohammad Kazem Sharbatdar has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Ali Kheyroddin
Faculty of Civil Engineering, Semnan University, Semnan, Iran
3 shared publications - Hosein Naderpour
Semnan University
3 shared publications - Reza Mahjub
Department of Pharmaceutics, School of Pharmacy, Hamadan University of Medical Sciences, Hamadan, Iran
3 shared publications Ali Kheyroddin
2 shared publicationsKhaled Sennah
Civil Engineering Department, Toronto Metropolitan University, Toronto, Canada
2 shared publicationsMasoud Haghani Chegeni
Ph.D. Candidate
2 shared publications
Latest Publications
- Open Access
- 16 September 2026
- Published by Springer Nature in Scientific Reports
Enhancing impact resistance of self-compacting concrete using recycled PET fibers and metallized plastic fibers: an integrated experimental and analytical investigation
The intrinsic brittleness of cementitious composites under localized dynamic loading, combined with the accumulating environmental burden of post-consumer polyethylene terephthalate (PET) and metallized plastic (MP) packaging waste, motivates the search for concrete mixtures that simultaneously provide energy-absorption capacity and material circularity. This study presents an integrated experimental and analytical assessment of self-compacting concrete (SCC) modified with recycled PET particles as a partial replacement for fine aggregate (0–15% by mass) and two families of discrete polymeric reinforcement, recycled PET fibers and metallized plastic fibers, incorporated at volume fractions of 0–2.0%. Twenty mixtures were proportioned at a constant water-to-cementitious-material ratio of 0.36, with silica fume contents of 5–20% and scoria lightweight coarse aggregate occupying approximately 40% of the total aggregate volume. A total of 240 specimens were characterized through fresh-state assessments (slump flow, V-funnel, L-box, J-ring, and U-tunnel), hardened mechanical testing (compressive, splitting tensile, and flexural strength, UPV, density, and water absorption), and repeated drop-weight impact loading adapted from ASTM D2444 using a 4.54 kg hammer released from 457 mm onto 150 × 65 mm discs. Filling and passing ability deteriorated monotonically with plastic content, with slump flow declining from 679 to 586 mm and V-funnel time increasing from 5.6 s to 10.8 s; linear regression demonstrated that the fiber-bearing series lost flowability more than twice as rapidly per unit PET addition (− 5.24 and − 5.60 mm/%) as the fiber-free series (− 2.49 and − 2.47 mm/%). Compressive strength peaked at 43.4 MPa in the unmodified reference, whereas the peak splitting tensile strength (9.2 MPa), flexural strength (5.28 MPa), and maximum impact resistance (486 blows; 10.8 kJ) occurred in PET-fiber mixtures with substantially lower compressive capacity. This mechanistic decoupling establishes that compressive strength is an unreliable proxy for impact toughness and identifies 10% PET replacement with 1.0–1.5% fiber as the governing design envelope.
- 16 September 2026
- Published by Springer Nature in Scientific Reports
Open AccessEnhancing impact resistance of self-compacting concrete using recycled PET fibers and metallized plastic fibers: an integrated experimental and analytical investigation
The intrinsic brittleness of cementitious composites under localized dynamic loading, combined with the accumulating environmental burden of post-consumer polyethylene terephthalate (PET) and metallized plastic (MP) packaging waste, motivates the search for concrete mixtures that simultaneously provide energy-absorption capacity and material circularity. This study presents an integrated experimental and analytical assessment of self-compacting concrete (SCC) modified with recycled PET particles as a partial replacement for fine aggregate (0–15% by mass) and two families of discrete polymeric reinforcement, recycled PET fibers and metallized plastic fibers, incorporated at volume fractions of 0–2.0%. Twenty mixtures were proportioned at a constant water-to-cementitious-material ratio of 0.36, with silica fume contents of 5–20% and scoria lightweight coarse aggregate occupying approximately 40% of the total aggregate volume. A total of 240 specimens were characterized through fresh-state assessments (slump flow, V-funnel, L-box, J-ring, and U-tunnel), hardened mechanical testing (compressive, splitting tensile, and flexural strength, UPV, density, and water absorption), and repeated drop-weight impact loading adapted from ASTM D2444 using a 4.54 kg hammer released from 457 mm onto 150 × 65 mm discs. Filling and passing ability deteriorated monotonically with plastic content, with slump flow declining from 679 to 586 mm and V-funnel time increasing from 5.6 s to 10.8 s; linear regression demonstrated that the fiber-bearing series lost flowability more than twice as rapidly per unit PET addition (− 5.24 and − 5.60 mm/%) as the fiber-free series (− 2.49 and − 2.47 mm/%). Compressive strength peaked at 43.4 MPa in the unmodified reference, whereas the peak splitting tensile strength (9.2 MPa), flexural strength (5.28 MPa), and maximum impact resistance (486 blows; 10.8 kJ) occurred in PET-fiber mixtures with substantially lower compressive capacity. This mechanistic decoupling establishes that compressive strength is an unreliable proxy for impact toughness and identifies 10% PET replacement with 1.0–1.5% fiber as the governing design envelope.
- Open Access
- 23 July 2026
- Published by Bilingual Publishing Group in Journal of Building Material Science
- p. 48-63
Experimental Assessment of Reinforced Concrete Incorporating Waste Tile Powder and Metakaolin under Aggressive Environmental Conditions
Concrete deterioration in aggressive environments poses significant challenges for the durability of reinforced concrete structures. The incorporation of supplementary cementitious materials offers a promising strategy to enhance performance while reducing cement consumption. This experimental study investigates the effects of metakaolin and waste ceramic tile powder as partial cement replacements on the compressive and flexural behavior of reinforced concrete members exposed to aggressive environmental conditions. Ten concrete mix designs were prepared with replacement levels of 10%, 20%, and 30% using metakaolin and waste tile powder. A total of 120 concrete cubes (100 mm) and 56 reinforced concrete slabs (40 × 200 × 600 mm) were cast and subjected to both standard curing and aggressive exposure regimes, including continuous immersion and alternating wet–dry cycles. The results demonstrate that the pozzolanic activity of metakaolin became more pronounced after 3–6 months, leading to enhanced mechanical performance. All mixtures containing waste tile powder exhibited higher compressive strength than the control mix. An increase of up to 11% in flexural capacity was observed for slabs incorporating 20% metakaolin, while slabs with 30% waste tile powder achieved an 8% improvement compared to lower replacement levels. Notably, specimens with 30% waste tile powder showed a significant increase in the experimental-to-nominal flexural capacity ratio, reaching values of 1.57 and 1.50 at 90 and 180 days, respectively. Overall, the combined use of metakaolin and waste tile powder improved durability and structural performance under aggressive conditions, indicating their potential for sustainable construction and rehabilitation of reinforced concrete structures.
- 23 July 2026
- Published by Bilingual Publishing Group in Journal of Building Material Science
- p. 48-63
Open AccessExperimental Assessment of Reinforced Concrete Incorporating Waste Tile Powder and Metakaolin under Aggressive Environmental Conditions
Concrete deterioration in aggressive environments poses significant challenges for the durability of reinforced concrete structures. The incorporation of supplementary cementitious materials offers a promising strategy to enhance performance while reducing cement consumption. This experimental study investigates the effects of metakaolin and waste ceramic tile powder as partial cement replacements on the compressive and flexural behavior of reinforced concrete members exposed to aggressive environmental conditions. Ten concrete mix designs were prepared with replacement levels of 10%, 20%, and 30% using metakaolin and waste tile powder. A total of 120 concrete cubes (100 mm) and 56 reinforced concrete slabs (40 × 200 × 600 mm) were cast and subjected to both standard curing and aggressive exposure regimes, including continuous immersion and alternating wet–dry cycles. The results demonstrate that the pozzolanic activity of metakaolin became more pronounced after 3–6 months, leading to enhanced mechanical performance. All mixtures containing waste tile powder exhibited higher compressive strength than the control mix. An increase of up to 11% in flexural capacity was observed for slabs incorporating 20% metakaolin, while slabs with 30% waste tile powder achieved an 8% improvement compared to lower replacement levels. Notably, specimens with 30% waste tile powder showed a significant increase in the experimental-to-nominal flexural capacity ratio, reaching values of 1.57 and 1.50 at 90 and 180 days, respectively. Overall, the combined use of metakaolin and waste tile powder improved durability and structural performance under aggressive conditions, indicating their potential for sustainable construction and rehabilitation of reinforced concrete structures.
- Open Access
- 1 January 2026
- Published by Wiley in Advances in Civil Engineering
- Vol. 2026 (1) , 4568260
Behavior of FRP‐Reinforced Concrete Columns Subjected to Combined Axial Compression and Lateral Loading
This study assessed the structural properties of carbon fiber‐reinforced polymer (CFRP)‐reinforced concrete columns through large‐scale experimental testing. Ten columns, representing a segment of a first‐story building column from the footing to the point of inflection, were tested under constant axial load to simulate seismic loading conditions. Test parameters included the arrangement of longitudinal bars, spacing of transverse reinforcement, specimen length, and level of constant axial load. Columns with higher CFRP bar content, reduced CFRP grid spacing, and higher axial compression levels exhibited ductile behavior, developing inelastic displacement with minimal strength loss before failure. The predominant failure mode was governed by concrete crushing, which preceded rupture of the CFRP reinforcement in tension. In compression, CFRP bars failed through an instability (buckling) mechanism distinct from that of steel reinforcing bars: unlike steel, which undergoes plastic deformation, CFRP bars exhibited significant bending prior to reaching instability, without any capacity for plastic yielding. All columns sustained applied drift ratios with no or only limited loss of lateral strength, exceeding the 2% and 2.5% drift limits specified for earthquake‐resistant columns in the National Building Code of Canada. Hysteretic behavior revealed stiffness degradation resulting from cracking and inelastic concrete crushing; however, the hysteresis loops of CFRP‐reinforced members differed markedly from those of steel‐reinforced columns. Displacement ductility ratios ranged from 1.9 to 3.4 depending on the test parameters, while drift ratios ranged from a maximum of 2% at peak lateral strength to an ultimate value of 4.55% at failure. To further evaluate the behavior of CFRP‐reinforced concrete members, a confined concrete model originally developed from tests on steel‐reinforced columns under concentric loading was applied. Analytical moment‐curvature and moment‐axial force interaction relationships were computed and compared against experimental results, with the confined concrete model underestimating experimental values by 5%–28%. These results confirm that plane‐section analysis remains applicable for evaluating the behavior of concrete members reinforced with FRP bars.
- 1 January 2026
- Published by Wiley in Advances in Civil Engineering
- Vol. 2026 (1) , 4568260
Open AccessBehavior of FRP‐Reinforced Concrete Columns Subjected to Combined Axial Compression and Lateral Loading
This study assessed the structural properties of carbon fiber‐reinforced polymer (CFRP)‐reinforced concrete columns through large‐scale experimental testing. Ten columns, representing a segment of a first‐story building column from the footing to the point of inflection, were tested under constant axial load to simulate seismic loading conditions. Test parameters included the arrangement of longitudinal bars, spacing of transverse reinforcement, specimen length, and level of constant axial load. Columns with higher CFRP bar content, reduced CFRP grid spacing, and higher axial compression levels exhibited ductile behavior, developing inelastic displacement with minimal strength loss before failure. The predominant failure mode was governed by concrete crushing, which preceded rupture of the CFRP reinforcement in tension. In compression, CFRP bars failed through an instability (buckling) mechanism distinct from that of steel reinforcing bars: unlike steel, which undergoes plastic deformation, CFRP bars exhibited significant bending prior to reaching instability, without any capacity for plastic yielding. All columns sustained applied drift ratios with no or only limited loss of lateral strength, exceeding the 2% and 2.5% drift limits specified for earthquake‐resistant columns in the National Building Code of Canada. Hysteretic behavior revealed stiffness degradation resulting from cracking and inelastic concrete crushing; however, the hysteresis loops of CFRP‐reinforced members differed markedly from those of steel‐reinforced columns. Displacement ductility ratios ranged from 1.9 to 3.4 depending on the test parameters, while drift ratios ranged from a maximum of 2% at peak lateral strength to an ultimate value of 4.55% at failure. To further evaluate the behavior of CFRP‐reinforced concrete members, a confined concrete model originally developed from tests on steel‐reinforced columns under concentric loading was applied. Analytical moment‐curvature and moment‐axial force interaction relationships were computed and compared against experimental results, with the confined concrete model underestimating experimental values by 5%–28%. These results confirm that plane‐section analysis remains applicable for evaluating the behavior of concrete members reinforced with FRP bars.
- Open Access
- 21 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 41222
Enhancing flexural behavior and ductility of fixed-end RC beams using high-performance fiber-reinforced cementitious composites
This paper investigates the effect of High-Performance Fiber-Reinforced Cementitious Composite (HPFRCC) with steel fibers on two fixed-end beams. Eight beams with identical sections were tested: two reference specimens and six reinforced with 1% or 2% steel fibers, with varied stirrup spacing near the beam ends. Results showed that fiber addition and stirrup adjustments markedly improved ductility and energy absorption. With 1% fibers, ductility nearly doubled, while 2% fibers more than doubled load capacity and tripled energy ductility. Adjusting loading points further enhanced strength and ductility. Overall, HPFRCC beams absorbed about 12% more energy than conventional concrete and extended the plastic hinge zone by nearly 50%.
- 21 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 41222
Open AccessEnhancing flexural behavior and ductility of fixed-end RC beams using high-performance fiber-reinforced cementitious composites
This paper investigates the effect of High-Performance Fiber-Reinforced Cementitious Composite (HPFRCC) with steel fibers on two fixed-end beams. Eight beams with identical sections were tested: two reference specimens and six reinforced with 1% or 2% steel fibers, with varied stirrup spacing near the beam ends. Results showed that fiber addition and stirrup adjustments markedly improved ductility and energy absorption. With 1% fibers, ductility nearly doubled, while 2% fibers more than doubled load capacity and tripled energy ductility. Adjusting loading points further enhanced strength and ductility. Overall, HPFRCC beams absorbed about 12% more energy than conventional concrete and extended the plastic hinge zone by nearly 50%.
- 23 September 2025
- Published by Elsevier in Journal of Building Engineering
- Vol. 113
Performance evaluation of deteriorated reinforced concrete flat slab-column connections: An experimental study
- 23 September 2025
- Published by Elsevier in Journal of Building Engineering
- Vol. 113
Performance evaluation of deteriorated reinforced concrete flat slab-column connections: An experimental study
- 8 July 2025
- Published by Springer Nature in Innovative Infrastructure Solutions
- Vol. 10 (8) , 1-18
Experimental investigation of the interaction between mechanical strength and skid resistance on the fiber-reinforced RCC pavements
- 8 July 2025
- Published by Springer Nature in Innovative Infrastructure Solutions
- Vol. 10 (8) , 1-18
Experimental investigation of the interaction between mechanical strength and skid resistance on the fiber-reinforced RCC pavements
- 1 February 2025
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Design and Construction Practice
- Vol. 30 (1)
Critical Factors Influencing the Labor Productivity of Mass Housing Construction
- 1 February 2025
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Design and Construction Practice
- Vol. 30 (1)
Critical Factors Influencing the Labor Productivity of Mass Housing Construction
- Open Access
- 20 December 2023
- Published by SCI AND TECH UNIVERSAL INC in Scientia Iranica
A hybrid unsupervised learning method for structural health monitoring by artificial neural networks and k-means clustering
This article proposes a hybrid unsupervised learning method as a combination of a novel two-level artificial neural network (TLANN) algorithm for data normalization regarding the removal of environmental variations and k-means clustering (KMC) for damage detection. In the proposed TLANN algorithm, feature samples are fed into the first neural network to generate its output and determine a residual matrix from the difference between the network input and output. In such a case, a new residual matrix from the difference between the input and output of the second network is extracted as the main feature for damage detection via the KMC, classical Silhouette value technique is applied to determine the number of clusters. The contribution of this article is to develop an innovative hybrid unsupervised learning method. The great advantages of this method consist in dealing with the negative effects of environmental variability and increasing the detectability of damage. The performance and reliability of the proposed method are validated by the well-known Z24 bridge along with several comparisons. Results show that the proposed hybrid method is highly capable of detecting damage and removing strong environmental variations. It is also observed that this method is superior to some classical and existing techniques.
- 20 December 2023
- Published by SCI AND TECH UNIVERSAL INC in Scientia Iranica
Open AccessA hybrid unsupervised learning method for structural health monitoring by artificial neural networks and k-means clustering
This article proposes a hybrid unsupervised learning method as a combination of a novel two-level artificial neural network (TLANN) algorithm for data normalization regarding the removal of environmental variations and k-means clustering (KMC) for damage detection. In the proposed TLANN algorithm, feature samples are fed into the first neural network to generate its output and determine a residual matrix from the difference between the network input and output. In such a case, a new residual matrix from the difference between the input and output of the second network is extracted as the main feature for damage detection via the KMC, classical Silhouette value technique is applied to determine the number of clusters. The contribution of this article is to develop an innovative hybrid unsupervised learning method. The great advantages of this method consist in dealing with the negative effects of environmental variability and increasing the detectability of damage. The performance and reliability of the proposed method are validated by the well-known Z24 bridge along with several comparisons. Results show that the proposed hybrid method is highly capable of detecting damage and removing strong environmental variations. It is also observed that this method is superior to some classical and existing techniques.