RCRichie L. C. Chen

Richie L. C. Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Richie L. C. Chen has a total of 25 co-authors. Here are the top co-authors by number of shared publications:

  • Tzong-Jih Cheng

    Department of Biomechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei, Taiwan

    8 shared publications
  • Bo-Chuan Hsieh

    Department of Biomechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei 10617, Taiwan

    6 shared publications
  • Tzong-Jih Cheng

    Department of Bio-Industrial Mechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei 10617, Taiwan

    4 shared publications
  • Hsien-Yi Hsiao

    National Taiwan University

    3 shared publications
  • Hsien-Yi Hsiao

    Department of Biomechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei 106, Taiwan

    3 shared publications
  • Kiyoshi Matsumoto

    Institute of Food Biotechnology, Department of Bioscience and Biotechnology, Division of Bioresource and Bioenvironmental Sciences, Kyushu University, Fukuoka 812-8581, Japan

    3 shared publications

Latest Publications

  • Open Access

    Portable Multi-Spectral Sensing Platform and Self-Metering Microfluidic Strips for Quantitative Monitoring of o-Phthalaldehyde Disinfectants

    by Hsien-Yi Hsiao, Tzong-Jih Cheng, Hung-Yu Chen, Richie L. C. Chen

    Routine monitoring of ortho-phthalaldehyde (OPA) disinfectants is critical for endoscope reprocessing, yet commercial test strips suffer from subjective visual ambiguity, strict manual timing, and susceptibility to sample matrix dilution. This study proposes a portable multi-spectral colorimetric sensing platform paired with structurally engineered microfluidic plastic strips for quantitative OPA monitoring. The strips utilize a confined microfluidic geometry to achieve capillary-driven volumetric self-metering (5.4 μL), while cross-hatched micro-structures eliminate edge pooling, yielding uniform colorimetric responses. Analytically, the system integrates a matrix-matched reagent formulation, an interference-free indicator, and an automated steady-state ratiometric readout algorithm to counteract physical dilution and spectral interference. Cross-validation against a capillary electrophoresis benchmark confirmed quantitative accuracy (R2 = 0.9684) under physical dilution of real-world CIDEX OPA solutions. This correlation facilitated a matrix-compensated 0.32% diagnostic threshold for unambiguous, automated “[PASS]” or “[FAIL]” alerts. Ultimately, this scalable, cost-effective microfluidic architecture provides an objective point-of-care diagnostic solution, demonstrating translational potential for broad dry chemistry optical detection.

  • Open Access

    Capacitive Biosensing of Skin Irritants Using a Lanolin-Based Artificial Stratum Corneum Model

    by Chung-Ting Cheng, Yi Kung, Hung-Yu Chen, Kuang-Hua Chang, Richie L. C. Chen, Tzong-Jih Cheng

    Skin irritation testing is transitioning toward non-animal alternatives that can replicate the functional properties of the human stratum corneum (SC). To address this need, we report a capacitive biosensing platform that integrates a lanolin-based artificial SC (aSC) for rapid, indicator-free detection of chemical irritants. The approach leverages a membrane-bound lipid matrix to detect changes in interfacial capacitance caused by chemical exposure. Among candidate materials, lanolin emerged as the most effective SC mimic, showing reproducible baseline stability and responsive dielectric shifts. The system quantifies barrier integrity through the capacitance change rate (ΔC/Δt), which serves as a real-time indicator of irritation potential. By positioning the biosensor as an analog of the SC and monitoring the dielectric environment during short exposures (7.5 min), we shift the paradigm from endpoint-based biochemical assays to rapid, physicochemical screening. This concept supports the advancement of ethical, scalable testing platforms that reduce reliance on animal or cellular models while maintaining sensitivity to barrier-compromising agents.


  • Open Access

    Redoxless Electrochemical Capacitance Spectroscopy for Investigating Surfactant Adsorption on Screen-Printed Carbon Electrodes

    by Tzong-Jih Cheng, Hsien-Yi Hsiao, Pei-Chia Tsai, Richie L. C. Chen

    Electrochemical impedance spectroscopy (EIS) is a sensitive analytical method for surface and bulk properties. Classical EIS and derived electrochemical capacitance spectroscopy (ECS) with a redox couple are label-free approaches for biosensor development, but doubts arise regarding interpretability when a redox couple is employed (redox EIS) due to interactions between electroactive probes and interfacial charges or forced potential. Here, we demonstrated redoxless ECS for directly determining surfactant adsorption on screen-printed carbon electrodes (SPCEs), validated through a simulation of equivalent circuits and the electrochemistry of electronic dummy cells. Redoxless ECS provides excellent capacitance plot loci for quantifying the interfacial permittivity of di-electric layers on electrode surfaces. Redoxless ECS was compared with redox EIS/ECS, revealing a favorable discrimination of interfacial capacitances under both low and high SDS coverage on SPCEs and demonstrating potential for probeless (reagentless) sensing. Furthermore, the proposed method was applied in an electrolyte without a redox couple and bare electrodes, obtaining a high performance for the adsorption of surfactants Tween-20, Triton-X100, sodium dodecyl sulfate, and tetrapropylammonium bromide. This approach offers a simple and straightforward means for a semi-quantitative evaluation of small molecule interactions with electrode surfaces. Our proposed approach may serve as a starting point for future probeless (reagentless) and label-free biosensors based on electrochemistry, eliminating disturbance with surface charge properties and minimizing forced potential bias by avoiding redox couples. An unambiguous and quantitative determination of physicochemical properties of biochemically recognizable layers will be relevant for biosensor development.


  • Open Access

    An Electrochemical o-Phthalaldehyde Sensor Using a Modified Disposable Screen-Printed Electrode with Polyacrylate Hydrogel for Concentration Verification of Clinical Disinfectant

    by Richie L. C. Chen, Bo-Chuan Hsieh, Jia-Sin Lin, Tzong-Jih Cheng

    The study proposes an o-phthalaldehyde (OPA) sensor for rapid and reliable detection of OPA in healthcare disinfection practices, based on a hydrogel-modified screen-printed carbon electrode strip. The hydrogel film, which contains glycine and N-acetylcysteine, reacts with OPA to produce a reductive isoindole derivative. The derivative is then oxidized for OPA determination using cyclic voltammetry. The proposed sensor achieves an optimal detection time of 20–30 s and requires only a small analyte volume of 5 µL. It exhibits good precision (10%) and sensitivity (3.3 μA/cm2 mM) in a phosphate-buffered solution (pH 7.6), with excellent linearity (R2 > 0.97) and precision (2 mM) and precision around the minimum effective concentration (0.3%). Overall, the proposed sensor offers a promising and practical solution for accurate and reliable OPA detection in clinical disinfection practices.


  • Open Access

    Hand-held Colorimetry Sensor Platform for Determining Salivary α-Amylase Activity and Its Applications for Stress Assessment

    by Hsien-Yi Hsiao, Richie L. C. Chen, Chih-Chi Chou, Tzong-Jih Cheng

    This study develops a hand-held stress assessment meter with a chemically colorimetric strip for determining salivary α-amylase activity, using a 3,5 dinitrosalicylic acid (DNS) assay to quantify the reducing sugar released from soluble starch via α-amylase hydrolysis. The colorimetric reaction is produced by heating the strip with a mini polyester heater plate at boiling temperature to form a brick red colored product, which measured at 525 nm wavelength. This investigation describes in detail the design, construction, and performance evaluation of a hand-held α-amylase activity colorimeter with a light emitted diode (LED) and photo-detector with built-in filters. The dimensions and mass of the proposed prototype are only 120 × 60 × 60 mm3 and 200 g, respectively. This prototype has an excellent correlation coefficient (>0.995), comparable with a commercial ultraviolet–visible spectroscope, and has a measurable α-amylase activity range of 0.1–1.0 U mL−1. The hand-held device can measure the salivary α-amylase activity with only 5 μL of saliva within 12 min of testing. This sensor platform effectively demonstrates that the level of salivary α-amylase activity increases more significantly than serum cortisol, the other physiological stressor biomarker, under physiologically stressful exercise conditions. Thus, this work demonstrates that the hand-held α-amylase activity meter is an easy to use and cost-effective stress assessment tool for psychoneuroendocrinology research.


  • High-Speed Mass Measurement of Nanoparticle and Virus

    by Huan-Chang Lin, Jung-Lee Lin, Hsin-Hung Lin, Shiue-Wen Tsai, Alice L. Yu, Richie L. C. Chen, Chung-Hsuan Chen

    Until now, there have been no relatively easy methods to measure the mass and mass distributions of nanoparticles/viruses. In this work, we report the first set of measurements of mass and mass distributions for nanoparticles/viruses using a novel mass spectrometry technology. In the past, mass spectrometry was typically used to measure the mass of a particle or molecule with a mass less than 1 000 000 Da. We developed cell mass spectrometry that can measure the mass of a cell or a microparticle. Nevertheless, there is a gap for mass measurement methods in the mass region of a nanoparticle or virus (1 MDa to 1 GDa). Here, we developed a nanoparticle/virus mass spectrometry technique to make rapid and accurate mass and mass distribution measurements of nanoparticles/viruses. This technique should be valuable for the quality control of nanoparticle production and the identification of various viruses. In the future, this method can also serve to monitor drug delivery when nanoparticles are used as carriers. Furthermore, it may be possible to measure the degree of infection by measuring the number of viruses in specific cells or in plasma.


  • Pencil lead microelectrode and the application on cell dielectrophoresis

    by Bo-Chuan Hsieh, Tzong-Jih Cheng, Syuan-He Shih, Richie L.C. Chen


  • Determination of tannic acid after precipitation with bovine serum albumin by visible light scattering in a flow injection system

    by Tzong-Jih Cheng, Hsien-Yi Hsiao, Chien-Yu Chung, Po-Chung Chen, Richie L. C. Chen


  • Potentiometric flow-injection estimation of tea fermentation degree

    by Chi-Hua Nieh, Bo-Chuan Hsieh, Po-Chung Chen, Hsien-Yi Hsiao, Tzong-Jih Cheng, Richie L.C. Chen