Tzong-Jih Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tzong-Jih Cheng has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Richie L. C. Chen
Department of Biomechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei 106, Taiwan
8 shared publications - Bo-Chuan Hsieh
Department of Biomechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei 10617, Taiwan
6 shared publications Po-Chung Chen
Department of Biomechatronic Engineering, College of Bioresources, National Ilan University, Yilan, Taiwan
5 shared publicationsHsien-Yi Hsiao
Department of Bio-Industrial Mechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei, Taiwan
3 shared publications- Hsien-Yi Hsiao
Department of Biomechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei 106, Taiwan
3 shared publications Richie L.C. Chen
Department of Bio-Industrial Mechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei, Taiwan
3 shared publications
Latest Publications
- Open Access
- 24 June 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (7) , 145
Portable Multi-Spectral Sensing Platform and Self-Metering Microfluidic Strips for Quantitative Monitoring of o-Phthalaldehyde Disinfectants
Routine monitoring of ortho-phthalaldehyde (OPA) disinfectants is critical for endoscope reprocessing, yet commercial test strips suffer from subjective visual ambiguity, strict manual timing, and susceptibility to sample matrix dilution. This study proposes a portable multi-spectral colorimetric sensing platform paired with structurally engineered microfluidic plastic strips for quantitative OPA monitoring. The strips utilize a confined microfluidic geometry to achieve capillary-driven volumetric self-metering (5.4 μL), while cross-hatched micro-structures eliminate edge pooling, yielding uniform colorimetric responses. Analytically, the system integrates a matrix-matched reagent formulation, an interference-free indicator, and an automated steady-state ratiometric readout algorithm to counteract physical dilution and spectral interference. Cross-validation against a capillary electrophoresis benchmark confirmed quantitative accuracy (R2 = 0.9684) under physical dilution of real-world CIDEX OPA solutions. This correlation facilitated a matrix-compensated 0.32% diagnostic threshold for unambiguous, automated “[PASS]” or “[FAIL]” alerts. Ultimately, this scalable, cost-effective microfluidic architecture provides an objective point-of-care diagnostic solution, demonstrating translational potential for broad dry chemistry optical detection.
- 24 June 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (7) , 145
Open AccessPortable Multi-Spectral Sensing Platform and Self-Metering Microfluidic Strips for Quantitative Monitoring of o-Phthalaldehyde Disinfectants
Routine monitoring of ortho-phthalaldehyde (OPA) disinfectants is critical for endoscope reprocessing, yet commercial test strips suffer from subjective visual ambiguity, strict manual timing, and susceptibility to sample matrix dilution. This study proposes a portable multi-spectral colorimetric sensing platform paired with structurally engineered microfluidic plastic strips for quantitative OPA monitoring. The strips utilize a confined microfluidic geometry to achieve capillary-driven volumetric self-metering (5.4 μL), while cross-hatched micro-structures eliminate edge pooling, yielding uniform colorimetric responses. Analytically, the system integrates a matrix-matched reagent formulation, an interference-free indicator, and an automated steady-state ratiometric readout algorithm to counteract physical dilution and spectral interference. Cross-validation against a capillary electrophoresis benchmark confirmed quantitative accuracy (R2 = 0.9684) under physical dilution of real-world CIDEX OPA solutions. This correlation facilitated a matrix-compensated 0.32% diagnostic threshold for unambiguous, automated “[PASS]” or “[FAIL]” alerts. Ultimately, this scalable, cost-effective microfluidic architecture provides an objective point-of-care diagnostic solution, demonstrating translational potential for broad dry chemistry optical detection.
- 21 February 2026
- Published by Elsevier in Food and Chemical Toxicology
- Vol. 212, 116024
Capacitive sensor-based artificial stratum corneum for skin irritating assessment of botanical insect repellent products and a de-irritation formulation
- 21 February 2026
- Published by Elsevier in Food and Chemical Toxicology
- Vol. 212, 116024
Capacitive sensor-based artificial stratum corneum for skin irritating assessment of botanical insect repellent products and a de-irritation formulation
- Open Access
- 28 August 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (9) , 564
Capacitive Biosensing of Skin Irritants Using a Lanolin-Based Artificial Stratum Corneum Model
Skin irritation testing is transitioning toward non-animal alternatives that can replicate the functional properties of the human stratum corneum (SC). To address this need, we report a capacitive biosensing platform that integrates a lanolin-based artificial SC (aSC) for rapid, indicator-free detection of chemical irritants. The approach leverages a membrane-bound lipid matrix to detect changes in interfacial capacitance caused by chemical exposure. Among candidate materials, lanolin emerged as the most effective SC mimic, showing reproducible baseline stability and responsive dielectric shifts. The system quantifies barrier integrity through the capacitance change rate (ΔC/Δt), which serves as a real-time indicator of irritation potential. By positioning the biosensor as an analog of the SC and monitoring the dielectric environment during short exposures (7.5 min), we shift the paradigm from endpoint-based biochemical assays to rapid, physicochemical screening. This concept supports the advancement of ethical, scalable testing platforms that reduce reliance on animal or cellular models while maintaining sensitivity to barrier-compromising agents.
- 28 August 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (9) , 564
Open AccessCapacitive Biosensing of Skin Irritants Using a Lanolin-Based Artificial Stratum Corneum Model
Skin irritation testing is transitioning toward non-animal alternatives that can replicate the functional properties of the human stratum corneum (SC). To address this need, we report a capacitive biosensing platform that integrates a lanolin-based artificial SC (aSC) for rapid, indicator-free detection of chemical irritants. The approach leverages a membrane-bound lipid matrix to detect changes in interfacial capacitance caused by chemical exposure. Among candidate materials, lanolin emerged as the most effective SC mimic, showing reproducible baseline stability and responsive dielectric shifts. The system quantifies barrier integrity through the capacitance change rate (ΔC/Δt), which serves as a real-time indicator of irritation potential. By positioning the biosensor as an analog of the SC and monitoring the dielectric environment during short exposures (7.5 min), we shift the paradigm from endpoint-based biochemical assays to rapid, physicochemical screening. This concept supports the advancement of ethical, scalable testing platforms that reduce reliance on animal or cellular models while maintaining sensitivity to barrier-compromising agents.
- 18 July 2024
- Published by Elsevier in Science of The Total Environment
- Vol. 948, 174841
Cellulose acetate-coated capacitive sensor for determining carbon-cycle enzymes activity and as a microbial Indicator for soil health
- 18 July 2024
- Published by Elsevier in Science of The Total Environment
- Vol. 948, 174841
Cellulose acetate-coated capacitive sensor for determining carbon-cycle enzymes activity and as a microbial Indicator for soil health
- 9 May 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 258, 116376
Nitrocellulose/acrylic resin coated screen-printed carbon electrode to construct a capacitive immunosensor for anti-BSA
- 9 May 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 258, 116376
Nitrocellulose/acrylic resin coated screen-printed carbon electrode to construct a capacitive immunosensor for anti-BSA
- 26 August 2023
- Published by Springer Nature in Analytical Sciences
- Vol. 39 (12) , 2007-2017
Determination of o-phthalaldehyde for dose verification of the clinical disinfectant by fluorescent sequential injection analysis
A new automated, generic analytical approach for determining the clinical disinfectant o-phthalaldehyde (OPA) is reported in this study. The proposed sequential injection analysis (SIA) is based on the online reaction of the OPA with glycine/N-acetylcysteine (NAC) in a neutral medium (pH = 7.0) to form a highly fluorescent isoindole derivative. All critical flow and reaction variables were investigated, while validation was carried out in the linearity detection range (0.0075–0.02%). As a result, excellent linearity (R2 > 0.99) and precision (1.5–2.4% for repeatability and 0.7–2.2% for reproducibility) were achieved for the reference OPA solutions. Furthermore, reasonable concentration verification of OPA disinfection (0.2–0.6%) in healthcare institutes can be achieved using the developed fluorescent SIA due to its good sensitivity (0.111 V/%) and precision (1.0–2.3% for intermediate precision) around the minimum effective concentration (MEC) of 0.3% for Cidex-OPA disinfectant. Graphical abstract
- 26 August 2023
- Published by Springer Nature in Analytical Sciences
- Vol. 39 (12) , 2007-2017
Determination of o-phthalaldehyde for dose verification of the clinical disinfectant by fluorescent sequential injection analysis
A new automated, generic analytical approach for determining the clinical disinfectant o-phthalaldehyde (OPA) is reported in this study. The proposed sequential injection analysis (SIA) is based on the online reaction of the OPA with glycine/N-acetylcysteine (NAC) in a neutral medium (pH = 7.0) to form a highly fluorescent isoindole derivative. All critical flow and reaction variables were investigated, while validation was carried out in the linearity detection range (0.0075–0.02%). As a result, excellent linearity (R2 > 0.99) and precision (1.5–2.4% for repeatability and 0.7–2.2% for reproducibility) were achieved for the reference OPA solutions. Furthermore, reasonable concentration verification of OPA disinfection (0.2–0.6%) in healthcare institutes can be achieved using the developed fluorescent SIA due to its good sensitivity (0.111 V/%) and precision (1.0–2.3% for intermediate precision) around the minimum effective concentration (MEC) of 0.3% for Cidex-OPA disinfectant. Graphical abstract
- Open Access
- 11 June 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (6) , 343
Redoxless Electrochemical Capacitance Spectroscopy for Investigating Surfactant Adsorption on Screen-Printed Carbon Electrodes
Electrochemical impedance spectroscopy (EIS) is a sensitive analytical method for surface and bulk properties. Classical EIS and derived electrochemical capacitance spectroscopy (ECS) with a redox couple are label-free approaches for biosensor development, but doubts arise regarding interpretability when a redox couple is employed (redox EIS) due to interactions between electroactive probes and interfacial charges or forced potential. Here, we demonstrated redoxless ECS for directly determining surfactant adsorption on screen-printed carbon electrodes (SPCEs), validated through a simulation of equivalent circuits and the electrochemistry of electronic dummy cells. Redoxless ECS provides excellent capacitance plot loci for quantifying the interfacial permittivity of di-electric layers on electrode surfaces. Redoxless ECS was compared with redox EIS/ECS, revealing a favorable discrimination of interfacial capacitances under both low and high SDS coverage on SPCEs and demonstrating potential for probeless (reagentless) sensing. Furthermore, the proposed method was applied in an electrolyte without a redox couple and bare electrodes, obtaining a high performance for the adsorption of surfactants Tween-20, Triton-X100, sodium dodecyl sulfate, and tetrapropylammonium bromide. This approach offers a simple and straightforward means for a semi-quantitative evaluation of small molecule interactions with electrode surfaces. Our proposed approach may serve as a starting point for future probeless (reagentless) and label-free biosensors based on electrochemistry, eliminating disturbance with surface charge properties and minimizing forced potential bias by avoiding redox couples. An unambiguous and quantitative determination of physicochemical properties of biochemically recognizable layers will be relevant for biosensor development.
- 11 June 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (6) , 343
Open AccessRedoxless Electrochemical Capacitance Spectroscopy for Investigating Surfactant Adsorption on Screen-Printed Carbon Electrodes
Electrochemical impedance spectroscopy (EIS) is a sensitive analytical method for surface and bulk properties. Classical EIS and derived electrochemical capacitance spectroscopy (ECS) with a redox couple are label-free approaches for biosensor development, but doubts arise regarding interpretability when a redox couple is employed (redox EIS) due to interactions between electroactive probes and interfacial charges or forced potential. Here, we demonstrated redoxless ECS for directly determining surfactant adsorption on screen-printed carbon electrodes (SPCEs), validated through a simulation of equivalent circuits and the electrochemistry of electronic dummy cells. Redoxless ECS provides excellent capacitance plot loci for quantifying the interfacial permittivity of di-electric layers on electrode surfaces. Redoxless ECS was compared with redox EIS/ECS, revealing a favorable discrimination of interfacial capacitances under both low and high SDS coverage on SPCEs and demonstrating potential for probeless (reagentless) sensing. Furthermore, the proposed method was applied in an electrolyte without a redox couple and bare electrodes, obtaining a high performance for the adsorption of surfactants Tween-20, Triton-X100, sodium dodecyl sulfate, and tetrapropylammonium bromide. This approach offers a simple and straightforward means for a semi-quantitative evaluation of small molecule interactions with electrode surfaces. Our proposed approach may serve as a starting point for future probeless (reagentless) and label-free biosensors based on electrochemistry, eliminating disturbance with surface charge properties and minimizing forced potential bias by avoiding redox couples. An unambiguous and quantitative determination of physicochemical properties of biochemically recognizable layers will be relevant for biosensor development.
- Open Access
- 17 April 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (4) , 485
An Electrochemical o-Phthalaldehyde Sensor Using a Modified Disposable Screen-Printed Electrode with Polyacrylate Hydrogel for Concentration Verification of Clinical Disinfectant
The study proposes an o-phthalaldehyde (OPA) sensor for rapid and reliable detection of OPA in healthcare disinfection practices, based on a hydrogel-modified screen-printed carbon electrode strip. The hydrogel film, which contains glycine and N-acetylcysteine, reacts with OPA to produce a reductive isoindole derivative. The derivative is then oxidized for OPA determination using cyclic voltammetry. The proposed sensor achieves an optimal detection time of 20–30 s and requires only a small analyte volume of 5 µL. It exhibits good precision (10%) and sensitivity (3.3 μA/cm2 mM) in a phosphate-buffered solution (pH 7.6), with excellent linearity (R2 > 0.97) and precision (2 mM) and precision around the minimum effective concentration (0.3%). Overall, the proposed sensor offers a promising and practical solution for accurate and reliable OPA detection in clinical disinfection practices.
- 17 April 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (4) , 485
Open AccessAn Electrochemical o-Phthalaldehyde Sensor Using a Modified Disposable Screen-Printed Electrode with Polyacrylate Hydrogel for Concentration Verification of Clinical Disinfectant
The study proposes an o-phthalaldehyde (OPA) sensor for rapid and reliable detection of OPA in healthcare disinfection practices, based on a hydrogel-modified screen-printed carbon electrode strip. The hydrogel film, which contains glycine and N-acetylcysteine, reacts with OPA to produce a reductive isoindole derivative. The derivative is then oxidized for OPA determination using cyclic voltammetry. The proposed sensor achieves an optimal detection time of 20–30 s and requires only a small analyte volume of 5 µL. It exhibits good precision (10%) and sensitivity (3.3 μA/cm2 mM) in a phosphate-buffered solution (pH 7.6), with excellent linearity (R2 > 0.97) and precision (2 mM) and precision around the minimum effective concentration (0.3%). Overall, the proposed sensor offers a promising and practical solution for accurate and reliable OPA detection in clinical disinfection practices.
- Open Access
Hand-held Colorimetry Sensor Platform for Determining Salivary α-Amylase Activity and Its Applications for Stress Assessment
This study develops a hand-held stress assessment meter with a chemically colorimetric strip for determining salivary α-amylase activity, using a 3,5 dinitrosalicylic acid (DNS) assay to quantify the reducing sugar released from soluble starch via α-amylase hydrolysis. The colorimetric reaction is produced by heating the strip with a mini polyester heater plate at boiling temperature to form a brick red colored product, which measured at 525 nm wavelength. This investigation describes in detail the design, construction, and performance evaluation of a hand-held α-amylase activity colorimeter with a light emitted diode (LED) and photo-detector with built-in filters. The dimensions and mass of the proposed prototype are only 120 × 60 × 60 mm3 and 200 g, respectively. This prototype has an excellent correlation coefficient (>0.995), comparable with a commercial ultraviolet–visible spectroscope, and has a measurable α-amylase activity range of 0.1–1.0 U mL−1. The hand-held device can measure the salivary α-amylase activity with only 5 μL of saliva within 12 min of testing. This sensor platform effectively demonstrates that the level of salivary α-amylase activity increases more significantly than serum cortisol, the other physiological stressor biomarker, under physiologically stressful exercise conditions. Thus, this work demonstrates that the hand-held α-amylase activity meter is an easy to use and cost-effective stress assessment tool for psychoneuroendocrinology research.
Open AccessHand-held Colorimetry Sensor Platform for Determining Salivary α-Amylase Activity and Its Applications for Stress Assessment
This study develops a hand-held stress assessment meter with a chemically colorimetric strip for determining salivary α-amylase activity, using a 3,5 dinitrosalicylic acid (DNS) assay to quantify the reducing sugar released from soluble starch via α-amylase hydrolysis. The colorimetric reaction is produced by heating the strip with a mini polyester heater plate at boiling temperature to form a brick red colored product, which measured at 525 nm wavelength. This investigation describes in detail the design, construction, and performance evaluation of a hand-held α-amylase activity colorimeter with a light emitted diode (LED) and photo-detector with built-in filters. The dimensions and mass of the proposed prototype are only 120 × 60 × 60 mm3 and 200 g, respectively. This prototype has an excellent correlation coefficient (>0.995), comparable with a commercial ultraviolet–visible spectroscope, and has a measurable α-amylase activity range of 0.1–1.0 U mL−1. The hand-held device can measure the salivary α-amylase activity with only 5 μL of saliva within 12 min of testing. This sensor platform effectively demonstrates that the level of salivary α-amylase activity increases more significantly than serum cortisol, the other physiological stressor biomarker, under physiologically stressful exercise conditions. Thus, this work demonstrates that the hand-held α-amylase activity meter is an easy to use and cost-effective stress assessment tool for psychoneuroendocrinology research.
- 1 April 2019
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 131, 53-59
Label-free and reagentless capacitive aptasensor for thrombin
- 1 April 2019
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 131, 53-59
Label-free and reagentless capacitive aptasensor for thrombin