ALAzien Laqmani

Azien Laqmani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Azien Laqmani has a total of 77 co-authors. Here are the top co-authors by number of shared publications:

  • Cyrus Behzadi

    Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany

    4 shared publications
  • Gerhard Adam

    Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Centre Hamburg-Eppendorf, Martinistrasse 52, D 20246, Hamburg, Germany

    4 shared publications
  • G. Adam

    Department of Diagnostic and Interventional Radiology and Nuclearmedicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany

    3 shared publications
  • Marc Regier

    Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg, Germany

    3 shared publications
  • Susanne Sehner

    Department of Medical Biometry and Epidemiology, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg, Germany

    3 shared publications
  • Cyrus Behzadi

    Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg, Germany

    2 shared publications

Latest Publications

  • Clinical Application of Ultrahigh-Field-Strength Wrist MRI: A Multireader 3-T and 7-T Comparison Study

    by Rafael Heiss, Marc-André Weber, Eva Balbach, Rainer Schmitt, Christoph Rehnitz, Azien Laqmani, Andreas Sternberg, Jutta J. Ellermann, Armin M. Nagel, Mark E. Ladd, et al.

    Ultrahigh-field-strength MRI at 7 T in patients with chronic wrist pain has potential advantages over 3-T MRI, particularly regarding visualization of cartilage, but superiority was not shown for a... Background Ultrahigh-field-strength MRI at 7 T may permit superior visualization of noninflammatory wrist pathologic conditions, particularly due to its high signal-to-noise ratio compared with the...


  • Vergleich zwischen quantitativer T2*-Analyse des retropatellaren Knorpels und der TTTG-Distanz bei jungen professionellen Fußballspielern

    by K Maas, M Warncke, C Behzadi, M Regier, A Laqmani, G Schön, M Kaul, G Adam, F Henes

    Zielsetzung Aktuell herrscht ein Diskurs über den Stellenwert der TTTG-Distanz (tibial tuberosity-trochlea groove) als Risikofaktor für Entstehung einer Knorpeldegeneration am Retropatellargelenk. Zur weiteren Klärung der Frage, welchen Einfluss die TTTG-Distanz auf initiale Knorpeldegenerationen hat, wurde eine quantitative MRT des retropatellaren Knorpels bei Nachwuchsprofis durchgeführt und ein Vergleich zwischen den T2*-Relaxationszeiten und der TTTG-Distanz erstellt. Material und Methoden Es wurden 36 Knie von 18 Profisportlern an einem 3T MRT untersucht. Für die quantitative Analyse wurden T2*-Messungen (22 Echozeiten zwischen 4,6-53,6 ms;) in 3D Akquisitionen in sagittaler Schichtführung angefertigt. Datensätze wurden mithilfe der Softwareapplizierung qMapit postprozessiert und quantitative Maps generiert. Die tiefen und oberflächlichen Schichten von insgesamt 12 prädefinierten Knorpelsegmenten in 3 Kompartimenten der Patella wurden analysiert. TTTG-Distanzen wurden in der MRT ermittelt und mit den quantitativen Messungen im Knorpel verglichen. Zur statistischen Analyse wurden ein Random-Effects-Modell sowie Student-T-test verwendet. Ergebnisse Es wurden signifikant erhöhte T2*-Relaxationszeiten in den oberflächlichen (Mittelwert ± Standardabweichung : 31,3 ± 3,8 ms), verglichen mit den tiefen Knorpelschichten (20,5 ± 4,2ms; Differenz -10,8 ms; p<0,001) ermittelt. Es wurde kein signifikanter Unterschied beim Vergleich der einzelnen Knorpelkompartimente detektiert. Die durchschnittliche TTTG-Distanz betrug 10±4 mm (Range 3-19 mm). Es konnte keine signifikante Korrelation zwischen der TTTG-Distanz und den T2*-Relaxationszeiten im retropatellaren Knorpel festgestellt werden. Schlußfolgerungen Es konnten keine erhöhten T2*-Relaxationszeiten als Indikator für initiale Knorpelschäden unter Bezugnahme erhöhter TTTG-Distanzen festgestellt werden. Unsere Ergebnisse unterstützen die Theorie, dass die TTTG-Distanz allein kein signifikanter Risikofaktor für die Entwicklung von Knorpeldegenerationen im Retropatellargelenk darstellt.

  • Feasibility of sub-milliSievert CT of the cervical spine: Initial results in fresh human cadavers

    by Julius Matthias Weinrich, Marc Regier, Lennart Well, Peter Bannas, Oleh Nykolyn, Axel Heinemann, Susanne Sehner, Cyrus Behzadi, Klaus Püschel, Gerhard Adam, et al.


  • CT der knöchernen Halswirbelsäule – wieviel Dosisreduktion ist möglich?

    by J Weinrich, M Regier, L Well, P Bannas, O Nykolyn, H Axel, S Sehner, K Püschel, G Adam, C Behzadi, et al.

    Zielsetzung: In dieser Studie sollte untersucht werden, wie weit sich die Strahlenexposition einer Computertomografie (CT) der Halswirbelsäule (HWS) bei noch diagnostisch akzeptabler Bildqualität senken lässt. Material und Methoden: Es wurde die HWS von 29 Leichen mittels jeweils vier Dosis-reduzierten CT (DRCT) Protokollen (DRCT-1 – 4) mit absteigender Referenz-Röhrenspannung (DRCT-1:70 mAs; DRCT-2:50 mAs; DRCT-3:30 mAs; DRCT-4:10 mAs) bei 140 kV untersucht. Ein klinisch implementiertes Protokoll diente hierbei als Referenz (160 mAs, 120 kV). Die Rohdaten wurden im Knochenkernel mittels gefilterter Rückprojektion (FBP) und zwei aufsteigenden Stufen der iterativen Rekonstruktion (IR) rekonstruiert. Die subjektive Bildqualität jeweils für die untere und obere HWS wurde von zwei Untersuchern geblindet beurteilt. Für die statistische Auswertung wurde ein gemischtes Effekt-Modell für wiederholte Messungen durchgeführt. Ein P-Wert von < 0,05 wurde als statistisch signifikant angesehen. Ergebnisse: Die Bildqualität der oberen HWS wurde, mit Ausnahme von DRCT-4 mit FBP, in allen Protokollen als diagnostisch akzeptabel beurteilt. Die Bildqualität der unteren HWS war für DRCT-3 mit FBP und DRCT-4 mit IR und FBP nicht akzeptabel. DRCT-3 mit IR war das am stärksten Dosis-reduzierte Protokoll, welches eine diagnostische akzeptable Bildqualität sowohl für die obere als auch die untere HWS erlaubte. Im Vergleich zum Referenz-Protokoll gab es eine signifikante Dosisreduktion in den DRCT Protokollen (Referenz: 1,5 ± 0,7 mSv; DRCT-1: 1 ± 0,6 mSv; DRCT-2: 0,7 ± 0,4 mSv; DRCT-3: 0,4 ± 0,2 mSv; DRCT-4: 0,2 ± 0,1 mSv; p < 0,001). Schlussfolgerungen: Dosis-reduzierte CT-Protokolle erlauben in Kombination mit IR die Durchführung von sub-mSv CT-Untersuchungen der HWS. Eine weitere Dosis-Senkung ist durch die verminderte Bildqualität der unteren HWS eingeschränkt. Das in dieser Arbeit noch als akzeptabel bewertete CT-Protokoll ist mit einer effektiven Dosis von 0,4 mSv einem Röntgenbild der HWS ähnlich und könnte dieses in Zukunft ersetzen.

  • Diagnosing acute pancreatitis—Clinical and radiological characterisation of patients without threefold increase of serum lipase

    by Maxim Avanesov, Anastassia Löser, Sarah Keller, Julius M. Weinrich, Azien Laqmani, Gerhard Adam, Murat Karul, Jin Yamamura


  • Comparison of image quality and visibility of normal and abnormal findings at submillisievert chest CT using filtered back projection, iterative model reconstruction (IMR) and iDose 4 ™

    by Azien Laqmani, Maxim Avanesov, Sebastian Butscheidt, Maximilian Kurfürst, Susanne Sehner, Jakob Schmidt-Holtz, Thorsten Derlin, Cyrus Behzadi, Hans D. Nagel, Gerhard Adam, et al.


  • Open Access

    CT Pulmonary Angiography at Reduced Radiation Exposure and Contrast Material Volume Using Iterative Model Reconstruction and iDose4 Technique in Comparison to FBP

    by Azien Laqmani, Maximillian Kurfürst, Sebastian Butscheidt, Susanne Sehner, Jakob Schmidt-Holtz, Cyrus Behzadi, Hans Dieter Nagel, Gerhard Adam, Marc Regier

    To assess image quality of CT pulmonary angiography (CTPA) at reduced radiation exposure (RD-CTPA) and contrast medium (CM) volume using two different iterative reconstruction (IR) algorithms (iDose4 and iterative model reconstruction (IMR)) in comparison to filtered back projection (FBP). 52 patients (body weight < 100 kg, mean BMI: 23.9) with suspected pulmonary embolism (PE) underwent RD-CTPA (tube voltage: 80 kV; mean CTDIvol: 1.9 mGy) using 40 ml CM. Data were reconstructed using FBP and two different IR algorithms (iDose4 and IMR). Subjective and objective image quality and conspicuity of PE were assessed in central, segmental, and subsegmental arteries. Noise reduction of 55% was achieved with iDose4 and of 85% with IMR compared to FBP. Contrast-to-noise ratio significantly increased with iDose4 and IMR compared to FBP (p4 and FBP. Conspicuity of central and segmental PE significantly improved with the use of IMR. In subsegmental arteries, iDose4 was superior to IMR. CTPA at reduced radiation exposure and contrast medium volume is feasible with the use of IMR, which provides improved image quality and conspicuity of pulmonary embolism in central and segmental arteries.


  • The immediate effect of long-distance running onT2andT2* relaxation times of articular cartilage of the knee in young healthy adults at 3.0 T MR imaging

    by Cyrus Behzadi, Goetz H Welsch, Azien Laqmani, Frank O Henes, Michael G Kaul, Gerhard Schoen, Gerhard Adam, Marc Regier

    Objective:To quantitatively assess the immediate effect of long-distance running on T2 and T2* relaxation times of the articular cartilage of the knee at 3.0 T in young healthy adults.Methods:30 healthy male adults (18–31 years) who perform sports at an amateur level underwent an initial MRI at 3.0 T with T2 weighted [16 echo times (TEs): 9.7–154.6 ms] and T2* weighted (24 TEs: 4.6–53.6 ms) relaxation measurements. Thereafter, all participants performed a 45-min run. After the run, all individuals were immediately re-examined. Data sets were post-processed using dedicated software (ImageJ; National Institute of Health, Bethesda, MD). 22 regions of interest were manually drawn in segmented areas of the femoral, tibial and patellar cartilage. For statistical evaluation, Pearson product–moment correlation coefficients and confidence intervals were computed.Results:Mean initial values were 35.7 ms for T2 and 25.1 ms for T2*. After the run, a significant decrease in the mean T2 and T2* relaxation times was obs...


  • Accuracy of Coronary Plaque Detection and Assessment of Interobserver Agreement for Plaque Quantification Using Automatic Coronary Plaque Analysis Software on Coronary CT Angiography

    by A. Laqmani, T. Klink, M. Quitzke, D. D. Creder, G. Adam, G. Lund

    Purpose: To evaluate the accuracy of automatic plaque detection and the interobserver agreement of automatic versus manually adjusted quantification of coronary plaques on coronary CT angiography (cCTA) using commercially available software. Materials and Methods: 10 cCTA datasets were evaluated using plaque software. First, the automatically detected plaques were verified. Second, two observers independently performed plaque quantification without revising the automatically constructed plaque contours (automatic approach). Then, each observer adjusted the plaque contours according to plaque delineation (adjusted approach). The interobserver agreement of both approaches was analyzed. Results: 32 of 114 automatically identified findings were true-positive plaques, while 82 (72 %) were false-positive. 20 of 52 plaques (38 %) were missed by the software (false-negative). The automatic approach provided good interobserver agreement with relative differences of 0.9 ± 16.0 % for plaque area and –3.3 ± 33.8 % for plaque volume. Both observers independently adjusted all contours because they did not represent the plaque delineation. Interobserver agreement decreased for the adjusted approach with relative differences of 25.0 ± 24.8 % for plaque area and 20.0 ± 40.4 % for plaque volume. Conclusion: The automatic plaque analysis software is of limited value due to high numbers of false-positive and false-negative plaque findings. The automatic approach was reproducible but it necessitated adjustment of all constructed plaque contours resulting in deterioration of the interobserver agreement. Key points: • Automatic plaque detection is limited due to high false-positive and false-negative findings. • Automatic plaque quantification was reproducible in the few accurately detected plaques. • The automatically constructed contours did not represent the plaque delineation. • Both observers independently adjusted the plaque contours. • Manual adjustment of plaque contours reduced the interobserver agreement. Citation Format: • Laqmani A, Klink T, Quitzke M et al. Accuracy of Coronary Plaque Detection and Assessment of Interobserver Agreement for Plaque Quantification Using Automatic Coronary Plaque Analysis Software on Coronary CT Angiography. Fortschr Röntgenstr 2016; 188: 933 – 939 Ziel: Evaluation der Detektionsgenauigkeit und der Interobserver-Übereinstimmung von automatischer gegenüber manuell adjustierter Quantifizierung von Koronarplaques mit der Koronar-CT-Angiografie (cCTA) unter Verwendung einer kommerziell erhältlichen Software. Material und Methoden: 10 cCTA-Datensätze wurden unter Verwendung einer Plaqueanalyse-Software evaluiert. Als erstes wurden die automatisch detektierten Plaques verifiziert. Danach führten 2 Untersucher unabhängig voneinander die automatische Plaque-Quantifizierung durch ohne die automatisch konstruierten Plaquekonturen zu revidieren (automatische Vorgehensweise). Anschließend konnten die Untersucher die Konturen gemäß der Plaquegrenzen anpassen (adjustierte Vorgehensweise). Die Interobserver-Übereinstimmung beider Vorgehensweisen wurde überprüft. Ergebnisse: 32 der 114 automatisch identifizierten Befunde waren richtig-positiv, während 82 (72 %) der Befunde falsch-positiv waren. 20 der 52 (38 %) Plaques wurden nicht von der Software detektiert (falsch-negativ). Die automatische Vorgehensweise bot eine gute Interobserver-Übereinstimmung mit relativen Unterschieden von 0,9 ± 16,0 % für Plaquefläche und –3,3 ± 33,8 % für Plaquevolumen. Beide Untersucher passten unabhängig von einander alle Plaquekonturen an, da die automatisch konstruierten Konturen nicht den Plaquegrenzen entsprachen. Die anschließende adjustierte Vorgehensweise verschlechterte die Interobserver-Übereinstimmung mit relativen Unterschieden von 25.0 ± 24.8 % für Plaquefläche und 20,0 ± 40,4 % für Plaquevolumen. Schlussfolgerung: Die untersuchte Software ist wegen vieler falsch-positiven und falsch-negativen Plaque-Detektionen von begrenztem Nutzen. Die automatische Vorgehensweise lieferte reproduzierbare Ergebnisse, benötigte jedoch eine Adjustierung sämtlicher Plaquekonturen, die zu einer Verschlechterung der Interobserver-Übereinstimmung führte. Kernaussagen: • Automatische Plaquedetektion ist durch hohe Raten an falsch-positiven und falsch-negativen Befunden limitiert. • Bei den wenigen korrekt detektierten Plaques ist die automatische Plaquequantifizierung reproduzierbar. • Die automatisch konstruierten Konturen entsprachen nicht den Plaquegrenzen. • Folglich passten beide Untersucher unabhängig von einander die Plaquekonturen an. • Diese Anpassung der Plaquekonturen führte zu einer Herabsetzung der Interobserver-Übereinstimmung.


  • Reduced-dose abdominopelvic CT using hybrid iterative reconstruction in suspected left-sided colonic diverticulitis

    by Azien Laqmani, Simon Veldhoen, Simon Dulz, Thorsten Derlin, Cyrus Behzadi, Jakob Schmidt-Holtz, Felicia Wassenberg, Susanne Sehner, Hans-Dieter Nagel, Gerhard Adam, et al.