CT Pulmonary Angiography at Reduced Radiation Exposure and Contrast Material Volume Using Iterative Model Reconstruction and iDose4 Technique in Comparison to FBP
Authors:
Open Access
- 9 September 2016
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (9) , e0162429
Abstract
To assess image quality of CT pulmonary angiography (CTPA) at reduced radiation exposure (RD-CTPA) and contrast medium (CM) volume using two different iterative reconstruction (IR) algorithms (iDose4 and iterative model reconstruction (IMR)) in comparison to filtered back projection (FBP). 52 patients (body weight < 100 kg, mean BMI: 23.9) with suspected pulmonary embolism (PE) underwent RD-CTPA (tube voltage: 80 kV; mean CTDIvol: 1.9 mGy) using 40 ml CM. Data were reconstructed using FBP and two different IR algorithms (iDose4 and IMR). Subjective and objective image quality and conspicuity of PE were assessed in central, segmental, and subsegmental arteries. Noise reduction of 55% was achieved with iDose4 and of 85% with IMR compared to FBP. Contrast-to-noise ratio significantly increased with iDose4 and IMR compared to FBP (p4 and FBP. Conspicuity of central and segmental PE significantly improved with the use of IMR. In subsegmental arteries, iDose4 was superior to IMR. CTPA at reduced radiation exposure and contrast medium volume is feasible with the use of IMR, which provides improved image quality and conspicuity of pulmonary embolism in central and segmental arteries.Keywords
This publication has 42 references indexed in Scilit:
- Optimizing Contrast Media Injection Protocols in State-of-the Art Computed Tomographic AngiographyInvestigative Radiology, 2015
- Value of knowledge-based iterative model reconstruction in low-kV 256-slice coronary CT angiographyJournal of Cardiovascular Computed Tomography, 2014
- Intraindividual Evaluation of the Influence of Iterative Reconstruction and Filter Kernel on Subjective and Objective Image Quality in Computed Tomography of the BrainRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2013
- Impact of Tube Current-Time and Tube Voltage Reduction in 64-Detector-row Computed Tomography Pulmonary Angiography for Pulmonary Embolism in a Porcine ModelJournal of Thoracic Imaging, 2012
- Initial Performance Characterization of a Clinical Noise–Suppressing Reconstruction Algorithm for MDCTAmerican Journal of Roentgenology, 2011
- Low volume contrast CTPA in patients with renal dysfunctionJournal of Medical Imaging and Radiation Oncology, 2011
- Multidetector Computed Tomography Chest Examinations With Low-Kilovoltage Protocols in AdultsJournal of Computer Assisted Tomography, 2009
- Management of Suspected Acute Pulmonary Embolism in the Era of CT Angiography: A Statement from the Fleischner SocietyRadiology, 2007
- Peripheral Pulmonary Arteries: How Far in the Lung Does Multi-Detector Row Spiral CT Allow Analysis?Radiology, 2001
- Contrast-media-induced nephrotoxicity: a consensus reportEuropean Radiology, 1999