Learning from adverse incidents involving medical devices
While an adverse event involving a medical device is often ascribed to either user error or device failure, the causes are typically multifactorial. A number of incidents involving medical devices are explored using this approach to investigate the various causes of the incident and the protective barriers that minimised or prevented adverse consequences. User factors, including mistakes, omissions and lack of training, conspired with background factors--device controls and device design, storage conditions, hidden device damage and physical layout of equipment when in use--to cause the adverse events. Protective barriers that prevented or minimised the consequences included staff vigilance, operating procedures and alarms.
- 2 April 2003
- Published by Royal College of Nursing in Nursing Standard
- Vol. 17 (29) , 41-46
Open AccessLearning from adverse incidents involving medical devices
While an adverse event involving a medical device is often ascribed to either user error or device failure, the causes are typically multifactorial. A number of incidents involving medical devices are explored using this approach to investigate the various causes of the incident and the protective barriers that minimised or prevented adverse consequences. User factors, including mistakes, omissions and lack of training, conspired with background factors--device controls and device design, storage conditions, hidden device damage and physical layout of equipment when in use--to cause the adverse events. Protective barriers that prevented or minimised the consequences included staff vigilance, operating procedures and alarms.
- 26 March 2003
- Published by Royal College of Nursing in Nursing Standard
- Vol. 17 (28) , 45-52
Infusion devices: characteristics, limitations and risk management
Safe administration of IV therapy requires skilled use of the equipment, knowledge of the associated risks and the prevention of adverse consequences. The authors outline the basic principles underpinning safe use of infusion devices.
- 26 March 2003
- Published by Royal College of Nursing in Nursing Standard
- Vol. 17 (28) , 45-52
Infusion devices: characteristics, limitations and risk management
Safe administration of IV therapy requires skilled use of the equipment, knowledge of the associated risks and the prevention of adverse consequences. The authors outline the basic principles underpinning safe use of infusion devices.
Learning from adverse incidents involving medical devices
Problem: The NHS is perceived to have a poor record of learning from incidents. Despite efforts of the Medical Devices Agency, which issues safety warnings, adverse incidents with medical devices continue to occur, some of which result in serious injury or death through device failures, user errors, and organisational problems. Design: Introduction of feedback notes on a supportive investigation that seeks to determine latent factors, immediate triggers, causes, and positive actions taken by staff that minimised adverse consequences. Background and setting: Medical physics department providing equipment management services in a major NHS teaching trust. Key measures for improvement: Reduction in repetitions of adverse incidents and improved staff competency in using devices. Strategy for change: A feedback note was developed to describe the incident and generic details of the equipment, summarise the investigation (focusing on latent causes and immediate triggers), and describe lessons to be learnt and positive actions by staff. Effects of change: Feedback notes have been used in teaching sessions and given to ward link nurses. Despite being new, the positive supportive approach has encouraged an open reporting culture. Lessons learnt: Adverse incidents are typically caused by alignment of different factors, but good practice can prevent errors becoming incidents. Careful analysis of incidents reveals both the multifactorial causes and the good practices that can help minimise repetitions.
Learning from adverse incidents involving medical devices
Problem: The NHS is perceived to have a poor record of learning from incidents. Despite efforts of the Medical Devices Agency, which issues safety warnings, adverse incidents with medical devices continue to occur, some of which result in serious injury or death through device failures, user errors, and organisational problems. Design: Introduction of feedback notes on a supportive investigation that seeks to determine latent factors, immediate triggers, causes, and positive actions taken by staff that minimised adverse consequences. Background and setting: Medical physics department providing equipment management services in a major NHS teaching trust. Key measures for improvement: Reduction in repetitions of adverse incidents and improved staff competency in using devices. Strategy for change: A feedback note was developed to describe the incident and generic details of the equipment, summarise the investigation (focusing on latent causes and immediate triggers), and describe lessons to be learnt and positive actions by staff. Effects of change: Feedback notes have been used in teaching sessions and given to ward link nurses. Despite being new, the positive supportive approach has encouraged an open reporting culture. Lessons learnt: Adverse incidents are typically caused by alignment of different factors, but good practice can prevent errors becoming incidents. Careful analysis of incidents reveals both the multifactorial causes and the good practices that can help minimise repetitions.
- 1 April 2000
- Vol. 5 (2) , 81-9
Can simulators evaluate systematic differences between oscillometric non-invasive blood-pressure monitors?
Oscillometric non-invasive blood-pressure (NIBP) monitors estimate the arterial pressure using model-specific signal processing and algorithms. Hence each model's accuracy must be clinically evaluated. Simulators may assist the evaluation, but their ability to do so has not been verified. To investigate whether simulators can detect systematic differences between NIBP monitors. We tested whether a simulator can distinguish between the two different algorithms available in a particular monitor, detect calibration errors and detect systematic differences between monitors that are observed clinically. Simulator evaluation correctly detected 1.8 and 4.2 mmHg systolic and diastolic differences between the two Nellcor N-3100 algorithms (with specified 2 and 5 mmHg differences) but found no difference between their mean arterial pressures (as expected from the specification). Simulator evaluations detected calibration adjustments at 80/50, 120/80 and 200/150 mmHg. Simulator and clinical comparisons of two devices of the same type recording slightly different blood pressures were in close agreement, but simulator and clinical comparisons of three different models (Propaq, Critikon DINAMAP and Datex Cardiocap) were not consistently in agreement. The simulators generated oscillometric pulse shapes different from physiological recordings. The results suggest that, although simulators can reveal systematic differences between devices of the same model, they cannot be used to detect systematic differences between different NIBP models. This could be at least partly because the oscillometric pulses generated by the simulators are dissimilar to physiologically recorded pulses.
- 1 April 2000
- Vol. 5 (2) , 81-9
Can simulators evaluate systematic differences between oscillometric non-invasive blood-pressure monitors?
Oscillometric non-invasive blood-pressure (NIBP) monitors estimate the arterial pressure using model-specific signal processing and algorithms. Hence each model's accuracy must be clinically evaluated. Simulators may assist the evaluation, but their ability to do so has not been verified. To investigate whether simulators can detect systematic differences between NIBP monitors. We tested whether a simulator can distinguish between the two different algorithms available in a particular monitor, detect calibration errors and detect systematic differences between monitors that are observed clinically. Simulator evaluation correctly detected 1.8 and 4.2 mmHg systolic and diastolic differences between the two Nellcor N-3100 algorithms (with specified 2 and 5 mmHg differences) but found no difference between their mean arterial pressures (as expected from the specification). Simulator evaluations detected calibration adjustments at 80/50, 120/80 and 200/150 mmHg. Simulator and clinical comparisons of two devices of the same type recording slightly different blood pressures were in close agreement, but simulator and clinical comparisons of three different models (Propaq, Critikon DINAMAP and Datex Cardiocap) were not consistently in agreement. The simulators generated oscillometric pulse shapes different from physiological recordings. The results suggest that, although simulators can reveal systematic differences between devices of the same model, they cannot be used to detect systematic differences between different NIBP models. This could be at least partly because the oscillometric pulses generated by the simulators are dissimilar to physiologically recorded pulses.
- 1 January 1995
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 19 (5) , 162-176
An automated system for the functional evaluation of oscillometric non-invasive blood pressure monitors
Most of the automated non-invasive blood pressure (NIBP) monitors in clinical use rely on the oscillometric technique for measuring the blood pressures. The functional evaluation of these monitors has relied on comparison with intra-arterial blood pressure measurements or comparison with ‘standard’ non-invasive blood pressure meters such as the Hawksley random zero sphygmomanometer. The commercial availability of simulated arm test instruments provides the opportunity for developing an alternative evaluation method. We describe the control of an NIBP simulator by a personal computer which is also linked to the NIBP monitor under test. An evaluation protocol is described and the data analysed to present graphically and in tabular form an assessment of the NIBP monitor.
- 1 January 1995
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 19 (5) , 162-176
An automated system for the functional evaluation of oscillometric non-invasive blood pressure monitors
Most of the automated non-invasive blood pressure (NIBP) monitors in clinical use rely on the oscillometric technique for measuring the blood pressures. The functional evaluation of these monitors has relied on comparison with intra-arterial blood pressure measurements or comparison with ‘standard’ non-invasive blood pressure meters such as the Hawksley random zero sphygmomanometer. The commercial availability of simulated arm test instruments provides the opportunity for developing an alternative evaluation method. We describe the control of an NIBP simulator by a personal computer which is also linked to the NIBP monitor under test. An evaluation protocol is described and the data analysed to present graphically and in tabular form an assessment of the NIBP monitor.