  • Comparison of 2 monocular pupillometers and an autorefractor for measurement of the dark-adapted pupil diameter

    by Sandra M. Brown, Jay C. Bradley

    To compare the performance of the Marco Nidek ARK-530A autorefractor pupillometer function and the Keeler PupilScan II pupillometer (study pupillometer) against the clinical standard NeurOptics PLR-200 pupillometer (standard pupillometer) for measurement of the dark-adapted pupil diameter. Department of Ophthalmology and Visual Sciences, Texas Tech University Health Sciences Center, Lubbock, Texas, USA. Evaluation of diagnostic test or technology. Subjects aged 20 to 60 years were dark-adapted for 2 minutes at 1 lux ambient illumination. Accommodation was controlled through distance fixation. The dark-adapted pupil diameter was measured with the standard pupillometer, then the study pupillometer, then the autorefractor. Results were compared using Bland-Altman graphs. The autorefractor underestimated the dark-adapted pupil diameter by a mean of 1.03 mm (range 0.0 to 2.3 mm). Thirty-four (85%) measurements were at least 0.5 mm smaller than the corresponding standard pupillometer values, and 16 (40%) were more than 1.0 mm smaller. Observer experience did not improve accuracy. The study pupillometer underestimated the dark-adapted pupil diameter by a mean of 0.31 mm (range 0.0 to 0.9 mm). Ten (25%) measurements were at least 0.5 mm smaller than the standard pupillometer values. Accuracy improved in the final 10 subjects (study pupillometer smaller; mean difference 0.16 mm; range 0.0 to 0.4 mm). The autorefractor pupillometry function had an unpredictable negative bias (variable underestimation of dark-adapted pupil diameter). The study pupillometer had a slight negative bias but required significant examiner skill and knowledge of normal pupil movement to obtain a valid result. Neither device was sufficiently accurate for confident surgical planning or clinical diagnosis. Neither author has a financial or proprietary interest in any material or method mentioned.


  • Dark-Adapted Pupil Diameter as a Function of Age Measured with the NeurOptics Pupillometer

    by Jay C. Bradley, Karl C. Bentley, Aleem I. Mughal, Hari Bodhireddy, Sandra M. Brown

    Purpose: To measure the dark-adapted pupil diameter of normal research participants in their second through ninth decades of life using the NeurOptics pupillometer (Neuroptics Inc). Methods: Individuals aged 18 to 80 years with no history of eye disease or injury, intraocular surgery, or use of systemic antihistamines or opiates were recruited. After 2 minutes of adaptation at 1 lux illumination, the right dark-adapted pupil diameter was measured using the NeurOptics pupillometer, with accommodation controlled by distance fixation. The NeurOptics pupillometer reported a mean dark-adapted pupil diameter and a standard deviation of the mean, which were analyzed as a function of age-decade. Results: Two-hundred sixty-three individuals participated. For participants aged 18 to 19 years (n=6), the mean dark-adapted pupil diameter was 6.85 mm (range: 5.6 to 7.5 mm); 20 to 29 years (n=66), 7.33 mm (range: 5.7 to 8.8 mm); 30 to 39 years (n=50), 6.64 mm (range: 5.3 to 8.7 mm); 40 to 49 years (n=51), 6.15 mm (range: 4.5 to 8.2 mm); 50 to 59 years (n=50), 5.77 mm (range: 4.4 to 7.2 mm); 60 to 69 years (n=30), 5.58 mm (range: 3.5 to 7.5 mm); 70 to 79 years (n=6), 5.17 mm (range: 4.6 to 6.0 mm); and 80 years (n=4), 4.85 mm (range: 4.1 to 5.3 mm). These values were consistent with studies using infrared photography. The standard deviation was >0.1 mm in 10 (3.8%) participants, all of whom were younger than 55 years. Conclusions: The dark-adapted pupil diameter is an important clinical variable when planning refractive surgery. Surgeons can compare a patient’s dark-adapted pupil diameter with the results of this population study to identify outlier measurements, which may be erroneous, and repeat testing prior to surgery.


  • Pediatric Refractive Surgery

    by Sandra M. Brown

    Is refractive surgery an appropriate treatment for some pediatric eye disorders? Proponents believe it is useful in the management of anisometropic amblyopia and bilateral high ametropia. Noncompliance with standard optical correction by glasses or contact lenses is the customary indication in the peer-reviewed literature. Authors argue that surgical treatment is better for the child than continued unsuccessful efforts at conventional optical management or discontinuation of therapy. Refractive surgery in pediatric patients functions as optical correction that cannot be removed at will, lost, or broken.


  • Time- and Temperature-Dependent Stability of Growth Factor Peptides in Human Autologous Serum Eye Drops

    by Jay C Bradley, Jan Dvm Simoni, Rachael H Bradley, David L McCartney, Sandra M Brown

    Purposes: To develop a step-by-step production method for human autologous serum (AS) eye drops that was broadly compliant with US Food and Drug Administration requirements for reinjection of processed biological substances. To determine optimum storage conditions for AS eye drops by measuring the concentration of growth factor peptides (GFP) as a function of storage temperature and storage duration. Methods: AS derived from the blood of 3 healthy male volunteers was produced using a closed, vacuum-driven, cascade-filtration system under sterile, low-pyrogen conditions. In-process controls included methods for monitoring protein electrophoretic mobility and degradation rate and the content of free hemoglobin and endotoxin. Stability of transforming growth factor β1, substance P, nerve growth factor, calcitonin gene-related peptide, insulin-like growth factor 1, and epidermal growth factor was evaluated at -15°C, +4°C, +25°C, +37°C, and +42°C at different time intervals (hours to weeks). The main outcome measures were the concentrations of GFP, endotoxin, and lipid peroxidation by-products (a proxy measure for protein degradation) in dilute AS. Results: The stability of GFP varies: transforming growth factor β1, nerve growth factor, epidermal growth factor, and insulin-like growth factor 1 were more temperature and time resistant, but substance P and calcitonin gene-related peptide significantly degraded at +4°C in 24 hours. Endotoxin and lipid peroxidation by-products were not significantly increased by processing. Conclusions: This pilot study developed a closed, cascade-filtration system that was an effective method for the production of high-quality, low-pyrogen AS. The processing method broadly complied with Food and Drug Administration requirements for reinjection of biological substances. Variable GFP stability was observed at +4°C and above. For clinical use, AS should be packaged in daily-use containers, which should be stored frozen; the container in active use should be refrigerated between doses.


  • The effective corneal refractive surface as a function of a point in visual space: a three‐dimensional analysis

    by Kenn A. Freedman, Sandra M. Brown

    Purpose:  To develop a three‐dimensional optical model of the anterior segment which will provide a basis for understanding the effects of corneal and adnexal problems on vision. Methods:  A three‐dimensional optical model of the anterior segment was developed to calculate the effective corneal refractive surface (ECRS), which is a specific area of cornea that refracts incident light rays arising from an object in visual space through the physical pupil (PP); light rays refracted by cornea outside the ECRS do not traverse the PP. This model incorporated the patient variables of central anterior chamber depth ( A ) and central corneal curvature ( K ). A vector analysis was combined with three‐dimensional analytic geometry to create a unified solution for all object locations in visual space. A computer program in BASIC on a PC was developed to perform the calculations. Results:  The ECRS was circular for objects on the line of sight, but with increasing displacement from the fixation point it became oval and eventually crescent shaped. The size of the ECRS increased as the distance of the object from the eye increased, but it rapidly reached a limiting value at about 200 mm. The size of the ECRS increased with PP diameter, but showed only a small dependence on A and minimal dependence on K . Conclusion:  This comprehensive optical model of object space and the anterior segment of the eye allows clinicians to better understand the effects of corneal light transmission on vision.