HWHsiang-Yu Wang

Hsiang-Yu Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hsiang-Yu Wang has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A PDMS-Based Cylindrical Hybrid Lens for Enhanced Fluorescence Detection in Microfluidic Systems

    by Bor-Shyh Lin, Yu-Ching Yang, Chong-Yi Ho, Han-Yu Yang, Hsiang-Yu Wang

    Microfluidic systems based on fluorescence detection have been developed and applied for many biological and chemical applications. Because of the tiny amount of sample in the system; the induced fluorescence can be weak. Therefore, most microfluidic systems deploy multiple optical components or sophisticated equipment to enhance the efficiency of fluorescence detection. However, these strategies encounter common issues of complex manufacturing processes and high costs. In this study; a miniature, cylindrical and hybrid lens made of polydimethylsiloxane (PDMS) to improve the fluorescence detection in microfluidic systems is proposed. The hybrid lens integrates a laser focusing lens and a fluorescence collecting lens to achieve dual functions and simplify optical setup. Moreover, PDMS has advantages of low-cost and straightforward fabrication compared with conventional optical components. The performance of the proposed lens is first examined with two fluorescent dyes and the results show that the lens provides satisfactory enhancement for fluorescence detection of Rhodamine 6G and Nile Red. The overall increments in collected fluorescence signal and detection sensitivity are more than 220% of those without lens, and the detection limits of Rhodamine 6G and Nile red are lowered to 0.01 μg/mL and 0.05 μg/mL, respectively. The hybrid lens is further applied to the detection of Nile red-labeled Chlorella vulgaris cells and it increases both signal intensity and detection sensitivity by more than 520%. The proposed hybrid lens also dramatically reduces the variation in detected signal caused by the deviation in incident angle of excitation light.


  • Current developments in high‐throughput analysis for microalgae cellular contents

    by Tsung‐Hua Lee, Jo‐Shu Chang, Hsiang‐Yu Wang

    Microalgae have emerged as one of the most promising feedstocks for biofuels and bio‐based chemical production. However, due to the lack of effective tools enabling rapid and high‐throughput analysis of the content of microalgae biomass, the efficiency of screening and identification of microalgae with desired functional components from the natural environment is usually quite low. Moreover, the real‐time monitoring of the production of target components from microalgae is also difficult. Recently, research efforts focusing on overcoming this limitation have started. In this review, the recent development of high‐throughput methods for analyzing microalgae cellular contents is summarized. The future prospects and impacts of these detection methods in microalgae‐related processing and industries are also addressed.


  • Rapid and in Vivo Quantification of Cellular Lipids in Chlorella vulgaris Using Near-Infrared Raman Spectrometry

    by Tsung-Hua Lee, Jo-Shu Chang, Hsiang-Yu Wang

    A rapid and noninvasive quantification method for cellular lipids in Chlorella vulgaris is demonstrated in this study. This method applied near-infrared Raman spectroscopy to monitor the change of signal intensities at 1440 cm–1 and 2845–3107 cm–1 along the nitrogen depletion period, and calibration curves relating signal intensity and cellular lipid abundance were established. The calibration curves show that signal intensity at 2845–3107 cm–1 and cellular lipid abundance were highly correlated. When the calibration curve was applied on the lipid quantification of two unknown samples, the differences between lipid abundances estimated by the calibration curve and measured by gas chromatography were less than 2 wt %. Carotenoids produced a strong and broad peak near 1440 cm–1, and it weakened the correlation between signal intensity and lipid abundance. The consistency of detection and effects of cellular contents and water on the Raman spectrogram of Chlorella vulgaris were also addressed. The sample pretreatment only involved centrifugation, and the time required for lipid quantification was shortened to less than 1.5 h. The rapid detection has great potential in high-throughput screening of microalgae and also provides valuable information for monitoring the quality of microalgae culture and determining parameters for the mass production of biodiesel from microalgae.


  • Enhanced fluorescence detection using liquid–liquid extraction in a microfluidic droplet system

    by Yan-Yu Chen, Zhao-Ming Chen, Hsiang-Yu Wang

    Reducing the fluorescence background in microfluidic assays is important in obtaining accurate outcomes and enhancing the quality of detections. This study demonstrates an integrated process including cell labelling, fluorescence background reduction, and biomolecule detection using liquid–liquid extraction in a microfluidic droplet system. The cellular lipids in Chlorella vulgaris and NIH/3T3 cells were labelled with a hydrophobic dye, Nile red, to investigate the performance of the proposed method. The fluorescence background of the lipid detection can be reduced by 85% and the removal efficiency increased with the volume of continuous phase surrounding a droplet. The removal rate of the fluorescence background increased as the surface area to volume ratio of a droplet increased. Before Nile red was removed from the droplet, the signal to noise ratio was as low as 1.30 and it was difficult to distinguish cells from the background. Removing Nile red increased the signal to noise ratio to 22 and 34 for Chlorella vulgaris and NIH/3T3, respectively, and these were 17 fold and 10 fold of the values before extraction. The proposed method successfully demonstrates the enhancement of fluorescence detection of cellular lipids and has great potential in improving other fluorescence-based detections in microfluidic systems.


  • Micro-sized microbial fuel cell: A mini-review

    by Hsiang-Yu Wang, Angela Bernarda, Chih-Yung Huang, Duu-Jong Lee, Jo-Shu Chang