Rolf F. Schulte
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rolf F. Schulte has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Florian Wiesinger
GE Healthcare, Munich, Germany
3 shared publications- Jim Wild
POLARIS, Division of Clinical Medicine, School of Medicine & Population Health, Faculty of Health The University of Sheffield Sheffield UK
2 shared publications - Markus Schwaiger
Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
2 shared publications Martin A. Janich
GE Global Research, Munich, Germany
2 shared publicationsAna Beatriz Solana
GE Healthcare, Munich, Germany
1 shared publicationAnne Menini
GE Healthcare, Menlo Park, California
1 shared publication
Latest Publications
- 2 November 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (4) , 2277-2287
Silent T2* and T2 encoding using ZTE combined with BURST
Purpose: To obtain T2* and T2‐weighted images as well as quantitative T2*, T2, and susceptibility maps with a novel, silent 3D imaging method, which combines zero‐echo‐time (ZTE) imaging with gradient‐ and spin‐echo BURST encoding.Methods: After a segment of standard ZTE encoding with multiple 3D radial k‐space spokes, the direction of traversing k‐space is reversed while excitation is switched off. This recalls gradient echoes for each spoke/excitation. This results in multiple images: one FID image from ZTE and multiple BURST echo images at different echo times weighted by a T2* decay. By adding a pair of 180° pulses with an appropriate wait period, it is also possible to obtain spin echoes, leading to T2‐weighted images. Data is reconstructed using standard 3D gridding and Fourier transformation. In vivo feasibility was demonstrated by imaging the brain of multiple healthy volunteers.Results: It is possible to acquire high‐quality T2*‐ and T2‐weighted brain images in a silent manner. From images acquired with gradient‐echo ZTE‐BURST, it is possible to extract quantitative T2* and magnetic susceptibility maps, whereas the spin echo version yields T2 maps.Conclusion: ZTE combined with BURST enables silent acquisition of T2*‐ and T2‐weighted images with good image quality.
- 2 November 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (4) , 2277-2287
Silent T2* and T2 encoding using ZTE combined with BURST
Purpose: To obtain T2* and T2‐weighted images as well as quantitative T2*, T2, and susceptibility maps with a novel, silent 3D imaging method, which combines zero‐echo‐time (ZTE) imaging with gradient‐ and spin‐echo BURST encoding.Methods: After a segment of standard ZTE encoding with multiple 3D radial k‐space spokes, the direction of traversing k‐space is reversed while excitation is switched off. This recalls gradient echoes for each spoke/excitation. This results in multiple images: one FID image from ZTE and multiple BURST echo images at different echo times weighted by a T2* decay. By adding a pair of 180° pulses with an appropriate wait period, it is also possible to obtain spin echoes, leading to T2‐weighted images. Data is reconstructed using standard 3D gridding and Fourier transformation. In vivo feasibility was demonstrated by imaging the brain of multiple healthy volunteers.Results: It is possible to acquire high‐quality T2*‐ and T2‐weighted brain images in a silent manner. From images acquired with gradient‐echo ZTE‐BURST, it is possible to extract quantitative T2* and magnetic susceptibility maps, whereas the spin echo version yields T2 maps.Conclusion: ZTE combined with BURST enables silent acquisition of T2*‐ and T2‐weighted images with good image quality.
- Open Access
- 6 January 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 73 (1) , 21-30
Radiofrequency pulse design for the selective excitation of dissolved129Xe
Purpose To optimize radiofrequency (RF) pulses for the selective excitation of dissolved phase 129Xe that take into account the very short T2*, while simultaneously, minimally exciting the much larger gas signal. Methods Numerical simulations of Shinnar le-Roux pulses and binomial coefficient composite-element pulses were performed and experimentally implemented on a 1.5 Tesla (T) clinical scanner. These were compared with pulses commonly used for short T2* imaging from the literature. The pulses were then experimentally tested in vivo with healthy volunteers inhaling hyperpolarized 129Xe using nuclear MR spectroscopy on a 1.5T clinical scanner. Results Standard RF excitation pulses inadvertently excite the gas compartment, or are long enough that the T2* of the dissolved compartment deteriorates the received signal. Amplitude modulated binomial composite pulses perform well being short and having high selectivity, however, deteriorate at high amplifier gain setting. Composite pulses using pulse width modulation provide the desired frequency response even in these nonlinear, high gain regimes. Conclusion Composite pulses provide a means of very narrow band frequency selectivity in a short duration pulse that is well suited to dissolved 129Xe imaging. Pulse width modulation maintains the desired frequency response even in the presence of amplitude distortion. Magn Reson Med 73:21–30, 2015.
- 6 January 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 73 (1) , 21-30
Open AccessRadiofrequency pulse design for the selective excitation of dissolved129Xe
Purpose To optimize radiofrequency (RF) pulses for the selective excitation of dissolved phase 129Xe that take into account the very short T2*, while simultaneously, minimally exciting the much larger gas signal. Methods Numerical simulations of Shinnar le-Roux pulses and binomial coefficient composite-element pulses were performed and experimentally implemented on a 1.5 Tesla (T) clinical scanner. These were compared with pulses commonly used for short T2* imaging from the literature. The pulses were then experimentally tested in vivo with healthy volunteers inhaling hyperpolarized 129Xe using nuclear MR spectroscopy on a 1.5T clinical scanner. Results Standard RF excitation pulses inadvertently excite the gas compartment, or are long enough that the T2* of the dissolved compartment deteriorates the received signal. Amplitude modulated binomial composite pulses perform well being short and having high selectivity, however, deteriorate at high amplifier gain setting. Composite pulses using pulse width modulation provide the desired frequency response even in these nonlinear, high gain regimes. Conclusion Composite pulses provide a means of very narrow band frequency selectivity in a short duration pulse that is well suited to dissolved 129Xe imaging. Pulse width modulation maintains the desired frequency response even in the presence of amplitude distortion. Magn Reson Med 73:21–30, 2015.
- Open Access
- 30 May 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 69 (5) , 1209-1216
Saturation‐recovery metabolic‐exchange rate imaging with hyperpolarized [1‐13C] pyruvate using spectral‐spatial excitation
Within the last decade hyperpolarized [1‐13C] pyruvate chemical‐shift imaging has demonstrated impressive potential for metabolic MR imaging for a wide range of applications in oncology, cardiology, and neurology. In this work, a highly efficient pulse sequence is described for time‐resolved, multislice chemical shift imaging of the injected substrate and obtained downstream metabolites. Using spectral‐spatial excitation in combination with single‐shot spiral data acquisition, the overall encoding is evenly distributed between excitation and signal reception, allowing the encoding of one full two‐dimensional metabolite image per excitation. The signal‐to‐noise ratio can be flexibly adjusted and optimized using lower flip angles for the pyruvate substrate and larger ones for the downstream metabolites. Selectively adjusting the excitation of the down‐stream metabolites to 90° leads to a so‐called “saturation‐recovery” scheme with the detected signal content being determined by forward conversion of the available pyruvate. In case of repetitive excitations, the polarization is preserved using smaller flip angles for pyruvate. Metabolic exchange rates are determined spatially resolved from the metabolite images using a simplified two‐site exchange model. This novel contrast is an important step toward more quantitative metabolic imaging. Goal of this work was to derive, analyze, and implement this “saturation‐recovery metabolic exchange rate imaging” and demonstrate its capabilities in four rats bearing subcutaneous tumors. Magn Reson Med, 2013.
- 30 May 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 69 (5) , 1209-1216
Open AccessSaturation‐recovery metabolic‐exchange rate imaging with hyperpolarized [1‐13C] pyruvate using spectral‐spatial excitation
Within the last decade hyperpolarized [1‐13C] pyruvate chemical‐shift imaging has demonstrated impressive potential for metabolic MR imaging for a wide range of applications in oncology, cardiology, and neurology. In this work, a highly efficient pulse sequence is described for time‐resolved, multislice chemical shift imaging of the injected substrate and obtained downstream metabolites. Using spectral‐spatial excitation in combination with single‐shot spiral data acquisition, the overall encoding is evenly distributed between excitation and signal reception, allowing the encoding of one full two‐dimensional metabolite image per excitation. The signal‐to‐noise ratio can be flexibly adjusted and optimized using lower flip angles for the pyruvate substrate and larger ones for the downstream metabolites. Selectively adjusting the excitation of the down‐stream metabolites to 90° leads to a so‐called “saturation‐recovery” scheme with the detected signal content being determined by forward conversion of the available pyruvate. In case of repetitive excitations, the polarization is preserved using smaller flip angles for pyruvate. Metabolic exchange rates are determined spatially resolved from the metabolite images using a simplified two‐site exchange model. This novel contrast is an important step toward more quantitative metabolic imaging. Goal of this work was to derive, analyze, and implement this “saturation‐recovery metabolic exchange rate imaging” and demonstrate its capabilities in four rats bearing subcutaneous tumors. Magn Reson Med, 2013.
- 8 March 2011
- Published by Wiley in NMR in Biomedicine
- Vol. 24 (9) , 1068-1072
Transmit gain calibration for nonproton MR using the Bloch–Siegert shift
Transmit gain (B) calibration is necessary for the adjustment of radiofrequency (RF) power levels to the desired flip angles. In proton MRI, this is generally an automated process before the actual scan without any user interaction. For other nuclei, it is usually time consuming and difficult, especially in the case of hyperpolarised MR. In the current work, transmit gain calibration was implemented on the basis of the Bloch–Siegert phase shift. From the same data, the centre frequency, line broadening and SNR could also be determined. The T1 and B0 insensitivity, and the wide range of B over which this technique is effective, make it well suited for nonproton applications. Examples are shown for hyperpolarised 13C and 3He applications. Copyright © 2011 John Wiley & Sons, Ltd.
- 8 March 2011
- Published by Wiley in NMR in Biomedicine
- Vol. 24 (9) , 1068-1072
Transmit gain calibration for nonproton MR using the Bloch–Siegert shift
Transmit gain (B) calibration is necessary for the adjustment of radiofrequency (RF) power levels to the desired flip angles. In proton MRI, this is generally an automated process before the actual scan without any user interaction. For other nuclei, it is usually time consuming and difficult, especially in the case of hyperpolarised MR. In the current work, transmit gain calibration was implemented on the basis of the Bloch–Siegert phase shift. From the same data, the centre frequency, line broadening and SNR could also be determined. The T1 and B0 insensitivity, and the wide range of B over which this technique is effective, make it well suited for nonproton applications. Examples are shown for hyperpolarised 13C and 3He applications. Copyright © 2011 John Wiley & Sons, Ltd.
- 13 November 2007
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 190 (2) , 271-279
Design of phase-modulated broadband refocusing pulses
- 13 November 2007
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 190 (2) , 271-279
Design of phase-modulated broadband refocusing pulses