Isidoros Vitellas
Research Subjects
Isidoros Vitellas has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Dionisios Pylarinos
Islands Network Operation Department, Hellenic Electricity Distribution Network Operator S.A. (HEDNO), Greece
2 shared publications - Eleftheria C. Pyrgioti
Department of Electrical and Computer Engineering, University of Patras, Patras, Greece
2 shared publications - Emmanuel Thalassinakis
Public Power Corporation (PPC), Terma Kastorias Str, 71307, Katsambas, Iraklion Crete, Greece
2 shared publications - Kiriakos Siderakis
Electrical Engineering Department,Technological Educational Institute of Crete, Greece
2 shared publications - Stratos David
Department of Biomedical Engineering, University of West Attica, Athens, Greece
1 shared publication
Latest Publications
- 31 March 2012
- Published by Elsevier in Electric Power Systems Research
- Vol. 84 (1) , 65-71
Online applicable techniques to evaluate field leakage current waveforms
- 31 March 2012
- Published by Elsevier in Electric Power Systems Research
- Vol. 84 (1) , 65-71
Online applicable techniques to evaluate field leakage current waveforms
- 31 January 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 18 (1) , 122-129
Impact of noise related waveforms on long term field leakage current measurements
Leakage current (LC) monitoring is widely employed in order to investigate electrical surface activity on high voltage (HV) insulators. Long term field monitoring is required in order to obtain an actual view of the phenomena. Therefore any monitoring system is bound to encounter data size problems. A number of solutions have been proposed to address this problem by extracting different values from the measured waveforms as a performance indication. However, a parameter that is fully representative of the waveform is yet to be determined. Hence, measuring and storing of the actual LC waveform is still required on sites for research and monitoring purposes. In addition, field related noise can result to misinterpretation of the actual activity. In this paper, a number of 26089 waveforms, recorded in a 150 kV Substation on four different post insulators that are part of the grid, are investigated. The monitoring period exceeded six years. Different techniques are applied and evaluated on the data set, employing simple numeric criteria and more advanced techniques such as Fourier and Wavelet analysis. Results are presented towards addressing the problems of noise and data size. The study objective is the incorporation of the results in improved leakage current monitoring systems.
- 31 January 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 18 (1) , 122-129
Impact of noise related waveforms on long term field leakage current measurements
Leakage current (LC) monitoring is widely employed in order to investigate electrical surface activity on high voltage (HV) insulators. Long term field monitoring is required in order to obtain an actual view of the phenomena. Therefore any monitoring system is bound to encounter data size problems. A number of solutions have been proposed to address this problem by extracting different values from the measured waveforms as a performance indication. However, a parameter that is fully representative of the waveform is yet to be determined. Hence, measuring and storing of the actual LC waveform is still required on sites for research and monitoring purposes. In addition, field related noise can result to misinterpretation of the actual activity. In this paper, a number of 26089 waveforms, recorded in a 150 kV Substation on four different post insulators that are part of the grid, are investigated. The monitoring period exceeded six years. Different techniques are applied and evaluated on the data set, employing simple numeric criteria and more advanced techniques such as Fourier and Wavelet analysis. Results are presented towards addressing the problems of noise and data size. The study objective is the incorporation of the results in improved leakage current monitoring systems.