JMJon Ingulf Medbø

Jon Ingulf Medbø

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jon Ingulf Medbø has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • New examination of the performance of the MetaMax I metabolic analyser with the Douglas-bag technique

    by Jon I. Medbø, Asgeir Mamen, Geir K. Resaland

    Purpose. To examine the performance of the MetaMax® I metabolic analyser of Cortex Biophysik, running a recent version of the software (MetaSoft v. 1.11.05), using the Douglas-bag method as reference. Experiments. First, 182 measurements of the maximal O2 uptake on school children were analysed both by a former version of the software (MetaMax Analysis) and by a recent version (MetaSoft). In further experiments, seven grown-up subjects of different fitness levels cycled for 5 min at constant powers between 50 and 350 W while the O2 uptake was measured simultaneously by the MetaMax I and the Douglas-bag method during the last minute of altogether 39 exercises. Results. The calculated maximal O2 uptake of the 182 school children was on average 3% lower when the data were reanalysed by MetaSoft than when analysed by the former version of the software. There was in addition a 2% variation. In further experiments on grown-up subjects the O2 uptake reported by the MetaMax I did not differ from that reported by the Douglas-bag system when data for all subjects were pooled, and the random error was 4%. However, the relationships differed slightly between the subjects (p = 0.005), and consequently the random error within each subject was 2–3%. The respiratory exchange ratio (R-value) reported by the MetaMax I differed systematically from that of the control method. However, a reliable R-value could be calculated from the instrument's raw data. Conclusions. Our data suggest that the MetaMax I running MetaSoft reports unbiased values of the O2 uptake and with moderate random error.


  • Blood flow in the brachial artery increases after intense cycling exercise

    by Jon Ingulf Medbø, Jonny Hisdal, Einar Stranden

    During cycling blood flow is redistributed from physically inactive tissues to working leg muscles. It is unknown how long this situation persists after very intense exercise or whether it differs between intense exhausting and non-exhausting exercise. It is also not known to what extent the redistribution differs between different types of non-active tissues. Therefore nine healthy young men cycled first for 2 min at 328 W (non-exhausting exercise, mean). Blood velocity in thigh and arm (ultrasound-doppler), perfusion of forearm skin (non-acral skin) and finger tip (acral skin, with arterio-venous anastomoses) were measured for 30 min after exercise (laser-doppler). To be able to study vascular resistance and central circulation, blood pressure (Finometer), heart rate (ECG), and stroke volume (ultrasound-doppler) were measured. Thereafter the subjects cycled at the same power to exhaustion (4 min), and the measurements were repeated. After both exercises mean blood pressure was unchanged (< or = 80 mm Hg) despite increased cardiac output (> or = + 30% vs. pre-exercise). Blood velocity in the brachial artery was higher during the whole recovery period than at rest (p< or =0.02; no differences between exercises). Blood perfusion of non-acral skin was unchanged from pre-exercise level after 2 min of non-exhausting exercise, but it was twice as high after 4 min cycling to exhaustion as at rest (p=0.02). Blood perfusion of acral skin rose after both exercises and did not differ between exhausting and non-exhausting exercise. In conclusion, arm blood flow increases above the pre-exercise level in the recovery period after short-lasting, strenuous exercise.


  • Examination of blood haemoglobin concentration measured using the OSM2

    by Jon Ingulf Medbø

    Blood haemoglobin concentration is regularly measured automatically by instruments reporting the value in around 1 min. The OSM2 from Radiometer is an example. Results from this instrument have been compared with those of a reference method using the hemiglobincyanide principle. Four healthy, moderately trained, young men (non‐smokers) cycled for 2 min to exhaustion. Blood samples were drawn from indwelling catheters in the femoral artery and vein before exercise, during exercise and in the 1 h recovery. Blood haemoglobin concentration was analysed using both methods. The results of the OSM2 were linearly related to those of the control method, with a random variation of 0.14 mmol L−1 (1.5 %). For arterial blood, the OSM2 showed a systematic bias of −0.36 mmol L−1 (−4 %). For femoral venous samples the bias varied depending on the haemoglobin concentration, being negative at low concentrations and positive at high values (−3 to +2 %). Consequently, the arteriovenous (a‐v) difference differed systematically between the two methods. The varying bias in the results of the OSM2 for femoral‐venous samples correlated with pH, pCO2, O2 saturation of haemoglobin (sO2) and with the haemoglobin concentration itself (cHb). Partial correlation analyses suggest that only the latter two correlations were independent, while correlations of the bias with pH and pCO2 were removed when correcting for the effect of sO2 and cHb. In conclusion, the OSM2 measures the blood haemoglobin concentration fairly precisely, but there is a variable bias of up to 4 % in absolute value. Finally, the instrument does not report a‐v differences reliably.


  • Leg gas exchange, release of glycerol, and uptake of fats after two minutes bicycling to exhaustion.

    by J.I. Medbø, E. Jebens

    It is not known to what extent the muscles use fats and carbohydrates as substrate for oxidation after intense, anaerobic types of bicycling. Six healthy young men therefore bicycled at constant power for 2 min to exhaustion. Blood was drawn from indwelling catheters in the femoral artery and vein at intervals during the 1-h postexercise recovery. The blood samples were analysed for concentrations of O2 and CO2, and for free fatty acids (FFA), triacylglycerols (TG), and glycerol in plasma. The blood flow was also measured, and the rate of leg uptake of FFA, TG, and O2 and the release of CO2 and glycerol as well as its gas exchange ratio were calculated and integrated over the recovery period. The leg gas exchange ratio integrated over the exercise plus 1-h recovery period was 0.67 +/- 0.06 (mean +/- SEM ), suggesting pure fat oxidation. There was no statistically significant arterial-femoral-venous difference of FFA across the leg. The concentration of TG in plasma fell by 0.18 +/- 0.09 mmol L(-1) (32%) during the first 10 min of the recovery period, and the leg took up 18 +/- 8 micromol TG kg(-1) body mass (bm) during the whole 1-h recovery period. Free glycerol was released from the leg throughout the recovery period in excess of that released from hydrolysis of TG from plasma, suggesting that 30 +/- 10 micromol TG kg (-1) bm was hydrolysed, probably from intra-muscular stores. If fully oxidized, the triacylglycerols hydrolysed can account for 101% of the measured O2 uptake. Thus, muscle seems to use only triacylglycerols as substrate for its oxidative energy release after intense exercise.


  • Effect of strenuous strength training on the Na-K pump concentration in skeletal muscle of well-trained men

    by Einar Jebens, Harald Vikne, Per Egil Refsnes, Petter Gramvik, Jon Ingulf Medbø


  • Lactate Release, Concentration in Blood, and Apparent Distribution Volume after Intense Bicycling.

    by Jon Ingulf Medbø, Karin Toska

    To study the release of lactate from muscle and its relationship to the blood lactate concentration during and after intense bicycling, young men cycled at 5.5 W kg(-1) body mass for 2 min to exhaustion or stopped after 1 min (nonexhaustive ride). The leg's release of lactate during and after each ride was taken from the measured blood flow and lactate concentrations in arterial and femoral-venous blood. Muscle biopsies were taken in separate experiments and analyzed for lactate. During the bicycling, 6 to 10% of the lactate produced was released to the blood. During exercise and for the first few minutes after, the rate of lactate release did not differ between 2 min exhaustive and 1 min nonexhaustive bicycling. The integrated release (exercise plus recovery) for the 1 min bicycling was 60 to 80% of the corresponding value of the 2 min exhaustive bicycling. In the late recovery, the blood lactate concentration was 3 to 5 times higher after 2 min exhaustive bicycling than after the 1 min nonexhaustive bicycling. There was thus a mismatch between the amount of lactate released and measured concentration in blood, reflecting a smaller distribution volume after the exhaustive bicycling. The blood lactate concentration may therefore not be a good measure of the lactate production and anaerobic energy release during bicycling.


  • Examination of four different instruments for measuring blood lactate concentration

    by J. I. Medbø, A. Mamen, O. Holt Olsen, E. Evertsen

    Information on the performance of different instruments used to measure blood lactate concentration is incomplete. We therefore examined instruments from Yellow Springs Instruments (YSI 23L and YSI 1500) and three cheaper and simpler instruments: Dr. Lange's LP8+, Lactate Pro from Arkray in the KDK corporation and Accusport from Boehringer Mannheim. First, a number of blood samples were analysed by standard enzymatic photofluorometry (our reference method) and, in addition, by one or more of the instruments mentioned above. Second, measurements using two or more identical instruments were compared. Third, since Lactate Pro and Accusport are small (approximately 100 g, pocket-size), battery-driven, instruments that could be used for outdoor testing, the performance of these instruments was examined at simulated altitudes (O2 pressure of <10 kPa) and at temperatures below -20 degrees C, while screening the instruments as much as possible from the cold. Most of the different instruments showed systematically too high or too low values (10-25% deviation). The observed differences between instruments may affect the "blood lactate threshold" by 2-5%. We found different readings between "equal" YSI 1500 instruments, while we could see no difference when comparing the other instruments of the same type. Lactate Pro gave reliable results at both -21+/-1 degrees C and at simulated altitude. Accusport gave reliable results in the cold, but 1.85+/-0.08 mmol L(-1) (mean+/-SD) too high readings at the simulated altitude. Of the three simpler instruments examined, the Lactate Pro was at least as good as the YSI instruments and superior to the other two.