W. Tiefenthaler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
W. Tiefenthaler has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
C. Keller
Department of Anaesthesia Schulthess Klinik Lengghalde Zürich Switzerland
3 shared publicationsJ. Brimacombe
Department of Anaesthesia and Intensive Care Cairns Base Hospital Australia
3 shared publicationsM. Kaufmann
Department of Anaesthesia and Intensive Care Medicine Medical University Innsbruck Austria
2 shared publicationsS. Eschertzhuber
Department of Anaesthesia and Intensive Care Medicine Medical University Innsbruck Austria
2 shared publicationsA. Tonin
Department of Anaesthesia and Intensive Care Medicine Medical University Innsbruck Innsbruck Austria
1 shared publicationD. Perkhofer
Department of Anaesthesia and Intensive Care Medicine Medical University Innsbruck Innsbruck Austria
1 shared publication
Latest Publications
- Open Access
- 1 April 2013
- Published by Wiley in Anaesthesia
- Vol. 68 (6) , 600-604
A randomised, non‐crossover study of the Guardian CPV™ Laryngeal Mask versus the LMA Supreme ™ in paralysed, anaesthetised female patients
Summary: We investigated the hypothesis that the oropharyngeal leak pressure would differ between the Guardian CPV™ and the LMA Supreme ™ in anaesthetised patients. We randomly assigned 120 patients to receive either the Guardian CPV or the LMA Supreme for airway management. Oropharyngeal leak pressure was measured during cuff inflation from 0 to 40 ml in 10‐ml steps. In addition, intracuff pressure, fibreoptic position of the airway and drain tube, device insertion success, ventilation success, blood staining and airway morbidity were determined. Mean ( SD ) oropharyngeal leak pressures for clinically acceptable cuff volumes of 20–40 ml were 31 (7) cmH 2 O for the Guardian CPV and 27 (7) cmH 2 O for the LMA Supreme (p < 0.0001); mean ( SD ) intracuff pressures were 68 (33) cmH 2 O and 88 (43) cmH 2 O (p < 0.0001), respectively. We found no differences in device insertion success, ventilation success, fibreoptic position of the airway and drain tube, blood staining or airway morbidity. We conclude that the oropharyngeal leak pressure is better for the Guardian CPV than for the LMA Supreme in anaesthetised patients.
- 1 April 2013
- Published by Wiley in Anaesthesia
- Vol. 68 (6) , 600-604
Open AccessA randomised, non‐crossover study of the Guardian CPV™ Laryngeal Mask versus the LMA Supreme ™ in paralysed, anaesthetised female patients
Summary: We investigated the hypothesis that the oropharyngeal leak pressure would differ between the Guardian CPV™ and the LMA Supreme ™ in anaesthetised patients. We randomly assigned 120 patients to receive either the Guardian CPV or the LMA Supreme for airway management. Oropharyngeal leak pressure was measured during cuff inflation from 0 to 40 ml in 10‐ml steps. In addition, intracuff pressure, fibreoptic position of the airway and drain tube, device insertion success, ventilation success, blood staining and airway morbidity were determined. Mean ( SD ) oropharyngeal leak pressures for clinically acceptable cuff volumes of 20–40 ml were 31 (7) cmH 2 O for the Guardian CPV and 27 (7) cmH 2 O for the LMA Supreme (p < 0.0001); mean ( SD ) intracuff pressures were 68 (33) cmH 2 O and 88 (43) cmH 2 O (p < 0.0001), respectively. We found no differences in device insertion success, ventilation success, fibreoptic position of the airway and drain tube, blood staining or airway morbidity. We conclude that the oropharyngeal leak pressure is better for the Guardian CPV than for the LMA Supreme in anaesthetised patients.
- 4 September 2012
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 56 (10) , 1321-1324
LMA ProSealTM vs. i‐GelTM in ventilated children: A randomised, crossover study using the size 2 mask
The Laryngeal Mask Airway (LMA) ProSeal(TM) and the i-Gel(TM) are two extraglottic devices with either an inflatable cuff or a non-inflatable cuff. We test the hypothesis that oropharyngeal leak pressure and fiberoptic position of the airway tube differ between the size 2 LMA ProSeal(TM) and the i-Gel(TM) in non-paralysed ventilated children. Fifty-one children aged 1.5-6 years weighing 10-25 kg were studied using a crossover design. Anaesthesia was with remifentanil/propofol mixture. The LMA ProSeal(TM) and the i-Gel(TM) were inserted into each patient in random order. Oropharyngeal leak pressure for the LMA ProSeal(TM) and the i-Gel(TM) was similar at 22 (5) and 21 (5) cm H(2) O, respectively. Fiberoptic position of the airway tube for the LMA ProSeal(TM) and the i-Gel(TM) was similar, with the vocal cords visible from the distal airway tube in 94% and 96%, respectively. We conclude that oropharyngeal leak pressure and fiberoptic position of the airway tube are similar for the size 2 LMA ProSeal(TM) and i-Gel(TM) in non-paralysed ventilated children.
- 4 September 2012
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 56 (10) , 1321-1324
LMA ProSealTM vs. i‐GelTM in ventilated children: A randomised, crossover study using the size 2 mask
The Laryngeal Mask Airway (LMA) ProSeal(TM) and the i-Gel(TM) are two extraglottic devices with either an inflatable cuff or a non-inflatable cuff. We test the hypothesis that oropharyngeal leak pressure and fiberoptic position of the airway tube differ between the size 2 LMA ProSeal(TM) and the i-Gel(TM) in non-paralysed ventilated children. Fifty-one children aged 1.5-6 years weighing 10-25 kg were studied using a crossover design. Anaesthesia was with remifentanil/propofol mixture. The LMA ProSeal(TM) and the i-Gel(TM) were inserted into each patient in random order. Oropharyngeal leak pressure for the LMA ProSeal(TM) and the i-Gel(TM) was similar at 22 (5) and 21 (5) cm H(2) O, respectively. Fiberoptic position of the airway tube for the LMA ProSeal(TM) and the i-Gel(TM) was similar, with the vocal cords visible from the distal airway tube in 94% and 96%, respectively. We conclude that oropharyngeal leak pressure and fiberoptic position of the airway tube are similar for the size 2 LMA ProSeal(TM) and i-Gel(TM) in non-paralysed ventilated children.
- Open Access
- 11 February 2012
- Published by Wiley in Anaesthesia
- Vol. 67 (4) , 407-410
Directly measured mucosal pressures produced by the i‐gel TM and laryngeal mask airway Supreme TM in paralysed anaesthetised patients
Summary: The i‐gel TM and LMA Supreme TM are extraglottic airway devices with non‐inflatable and inflatable cuffs, respectively. We hypothesised that directly measured mucosal pressures would differ between these devices in anesthetised paralysed patients. Thirty patients were randomly allocated to receive one of these two devices. Four pressure sensors were attached to all airway devices used to measure mucosal pressure at the base of the tongue, the distal oropharynx, the hypopharynx and the pyriform fossa. At these four places, median (IQR [range]) i‐gel mucosal pressures were 8.0 (2.7–10.7 [0–26.7]), 5.0 (2.7–7 [1.0–37.3]), 9.3 (2.7–13.3 [0–22.7] and 8.0 (2.7–10.7 [0–25.3]) cmH 2 O, respectively, and for the LMA Supreme, these were 5.0 (0.5–8.0 [0–33]), 4.0 (1.3–9.3 [0–24]), 10.7 (4–17.3 [0–26.7]) and 8.0 (0–10.7 [0–36]) cmH 2 O, respectively. Mucosal pressures were low and similar for both devices. The LMA Supreme mucosal pressures were higher in the hypopharynx than in the distal oropharynx (p = 0.04) and base of the tongue (p = 0.011). There were no pressure differences between the locations for the i‐gel.
- 11 February 2012
- Published by Wiley in Anaesthesia
- Vol. 67 (4) , 407-410
Open AccessDirectly measured mucosal pressures produced by the i‐gel TM and laryngeal mask airway Supreme TM in paralysed anaesthetised patients
Summary: The i‐gel TM and LMA Supreme TM are extraglottic airway devices with non‐inflatable and inflatable cuffs, respectively. We hypothesised that directly measured mucosal pressures would differ between these devices in anesthetised paralysed patients. Thirty patients were randomly allocated to receive one of these two devices. Four pressure sensors were attached to all airway devices used to measure mucosal pressure at the base of the tongue, the distal oropharynx, the hypopharynx and the pyriform fossa. At these four places, median (IQR [range]) i‐gel mucosal pressures were 8.0 (2.7–10.7 [0–26.7]), 5.0 (2.7–7 [1.0–37.3]), 9.3 (2.7–13.3 [0–22.7] and 8.0 (2.7–10.7 [0–25.3]) cmH 2 O, respectively, and for the LMA Supreme, these were 5.0 (0.5–8.0 [0–33]), 4.0 (1.3–9.3 [0–24]), 10.7 (4–17.3 [0–26.7]) and 8.0 (0–10.7 [0–36]) cmH 2 O, respectively. Mucosal pressures were low and similar for both devices. The LMA Supreme mucosal pressures were higher in the hypopharynx than in the distal oropharynx (p = 0.04) and base of the tongue (p = 0.011). There were no pressure differences between the locations for the i‐gel.