XTXiangyang Tang

Xiangyang Tang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xiangyang Tang has a total of 226 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Need for Demonstrated Clinical Translational Evidence in Submissions to the IEEE Journal of Translational Engineering in Health and Medicine

    by Gerard Boyle, Arturo Forner-Cordero, Anubha Kalra, Vaclav Kremen, Alfonso Maria Ponsiglione, Mahsa Ranji, Sharad Sinha, Xiangyang Tang, Po Yang, Richard B. Reilly

    The IEEE Journal of Translational Engineering in Health and Medicine (JTEHM) exists at the intersection of biomedical engineering and clinical practice. Published articles go beyond laboratory proof-of-concept to provide tangible, real-world evidence of translation into clinical settings. This editorial provides the rationale for manuscripts submitted to IEEE JTEHM to demonstrate evidence of clinical translation. It also provides examples of acceptable forms of evidence and offers guidance to authors on how to meet this expectation. Clinical and Impact—By requiring demonstrated clinical translational evidence IEEE JTEHM endeavours to publish high-quality research with scientific novelty and practical clinical impact. This expectation strengthens the journal’s aim to accelerate the adoption of innovative solutions into healthcare systems and ultimately deliver quantifiable benefits to patients.


  • Open Access

    Dual‐focal‐spot single‐detector CT: A simulation study to assess cone‐beam artifacts and noise

    by Baojun Li, Xiangyang Tang

    Background: Ultra‐wide coverage CT (> 128 detector rows) makes it possible to image a heart or brain in a single rotation but are associated with large cone angles, which can severely degrade the image quality. Purpose: This study evaluate the image quality and artifact levels of a dual‐focal‐spot single‐detector (DFSSD) CT geometry designed to achieve 140 mm z‐axis coverage, through a simulation study. Methods: The DFSSD CT system employs two x‐ray focal spots spaced 90 mm apart along the z‐axis and a 100 mm CT detector. It provides 140 mm z‐axis coverage at the iso‐center. A research CT simulation package (CatSim) was employed throughout this study. To compare the image quality, three system geometries were simulated: (A) single focal spot with 40 mm detector (VCT40), (B) single focal spot with 140 mm detector (VCT140), and (C) the DFSSD CT system. A simulated helical body phantom (45 cm x 30 cm x 16 cm) containing various bony structures was used to assess cone‐beam artifacts and noise uniformity across the edge, central, and intermediate slices under different acquisition modes: axial half scan, axial full scan, and helical scan at various helical pitch (0.5, 0.75, 1.0). All images were reconstructed using a cone‐beam filtered back‐projection algorithm with 3D cone‐angle‐dependent pixel‐wise weighting. Results: Under helical scan conditions (pitch 0.5 to 1.0), all geometries demonstrated similar levels of cone‐beam artifacts and noises. Slightly increased artifacts observed on some slices in VCT140 and DFSSD CT, but overall image quality are acceptable. However, under axial half scan condition, the VCT140 geometry exhibited significantly worse artifacts and image uniformity in intermediate and edge slices compared to VCT40, whereas DFSSD CT showed artifact and image uniformity comparable to VCT40. Conclusion: Simulation results indicate that the DFSSD CT geometry can achieve 140 mm z‐axis coverage while maintaining image quality similar to the VCT40 system.

  • Open Access

    Optimization-based image reconstruction regularized with inter-spectral structural similarity for limited-angle dual-energy cone-beam CT

    by Junbo Peng, Tonghe Wang, Huiqiao Xie, Richard L J Qiu, Chih-Wei Chang, Justin Roper, David S Yu, Xiangyang Tang, Xiaofeng Yang

    Objective. Limited-angle dual-energy (DE) cone-beam CT (CBCT) is considered as a potential solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, its clinical implementations are hindered by the challenging image reconstruction from limited-angle projections. While optimization-based and deep learning-based methods have been proposed for image reconstruction, their utilization is limited by the requirement for x-ray spectra measurement or paired datasets for model training. This work aims to facilitate the clinical applications of fast and low-dose DE-CBCT by developing a practical solution for image reconstruction in limited-angle DE-CBCT. Approach. An inter-spectral structural similarity-based regularization was integrated into the iterative image reconstruction in limited-angle DE-CBCT. By enforcing the similarity between the DE images, limited-angle artifacts were efficiently reduced in the reconstructed DECBCT images. The proposed method was evaluated using two physical phantoms and three digital phantoms, demonstrating its efficacy in quantitative DECBCT imaging. Main results. In all the studies, the proposed method achieves accurate image reconstruction without visible residual artifacts from limited-angle DE-CBCT projection data. In the digital phantom studies, the proposed method reduces the mean-absolute-error from 309/290 HU to 14/20 HU, increases the peak signal-to-noise ratio from 40/39 dB to 70/67 dB, and improves the structural similarity index measurement from 0.74/0.72–1.00/1.00. Significance. The proposed method can efficiently reduce limited-angle artifacts during the image reconstruction, enabling quantitative DE-CBCT with comparable data acquisition time and radiation dose to that of a single-energy scan on current onboard scanners without hardware modification. This work is of great clinical significance and can boost the clinical application of DE-CBCT in image-guided radiation therapy and surgical interventions.


  • Open Access

    Noise correlation and its impact on the performance of multi‐material decomposition‐based spectral imaging in photon‐counting CT

    by Xiangyang Tang, Yan Ren, Huiqiao Xie

    Purpose: It has been known that noise correlation plays an important role in the determination of the performance of spectral imaging based on two‐material decomposition (2‐MD). To further understand the basics of spectral imaging in photon‐counting CT toward optimal design and implementation, we study the noise correlation in multi‐MD (m‐MD) and its impact on the performance of spectral imaging.Method: We derive the equations that characterize the noise and noise correlation in the material‐specific (basis) images inm‐MD, followed by a simulation study to verify the derived equations and study the noise correlation's impact on the performance of spectral imaging. Using a specially designed digital phantom, the study of noise correlation runs over the cases of two‐, three‐, and four‐MD (2‐MD, 3‐MD, and 4‐MD). Then, the noise correlation's impact on the performance of spectral imaging in photon‐counting CT is investigated, using a modified Shepp–Logan phantom.Results: The results in 2‐MD show that, in‐line with what has been reported in the literature, the noise correlation coefficient between the material‐specific images corresponding to the basis materials approaches −1. The results inm‐MD (m ≥ 3) are more complicated and interesting, as the noise correlation coefficients between a pair of the material‐specific images alternate between ±1, and so do in the case of 4‐MD. Them‐MD data show that the noise in virtual monochromatic imaging (a form of spectral imaging) is moderate even though the noises in material‐specific (basis) images vary drastically.Conclusions: The observation of noise correlation in 3‐MD, 4‐MD, and beyond (i.e.,m‐MD) is informative to the community. The relationship between noise correlation and the performance of spectral imaging revealed in this work may help clinical medical physicists understand the fundamentals of spectral imaging based on MD and optimize the performance of spectral imaging in photon‐counting CT and other X‐ray imaging modalities.


  • Photon‐counting CT via interleaved/gapped spectral channels: Feasibility and imaging performance

    by Xiangyang Tang, Yan Ren, Huiqiao Xie

    Purpose Compared to energy-integration, photon-counting x-ray detection facilitates the spectral channelization (energy binning) in spectral CT and thus offers the opportunity of implementing data acquisition via sophisticated schemes, e.g., gapping or interleaving in spectral channels. In this article, we report our investigation of the performance of material decomposition based spectral imaging in photon-counting CT implemented in such data acquisition schemes, and their comparison with the benchmark scheme and other schemes without spectral gapping or interleaving. Materials and Methods Using a deliberately designed anthropomorphic head phantom that mimics the intracranial soft tissues and bony structures, a simulation study is carried out with the focus on two-material decomposition-based spectral imaging in photon-counting CT, under both ideal and realistic detector spectral responses. The projection data are acquired in four spectral channels, and then are sorted to implement the schemes of gapping ((ch1, ch3); (ch2, ch4); (ch1, ch4)) and interleaving ((ch1, ch3)+(ch2, ch4); (ch1, ch4)+(ch2, ch3); ((ch1+ch3), (ch2+ch4)); ((ch1+ch4), (ch2+ch3))) in spectral channels, in addition to the benchmark scheme ((ch1+ch2), (ch3+ch4)) and other conventional schemes (ch1, ch2), (ch2, ch3) and (ch3, ch4), where ‘ch’ denotes channel, ‘+’ denote addition, and (·,·) the operation of material decomposition and image reconstruction. Using the contrast-to-noise ratio between targeted regions of interest as the figure of merit, we study the performance of spectral imaging (material specific and virtual monochromatic) associated with these spectral channelization schemes. Results Under ideal detector spectral response, the scheme (ch1, ch4) outperforms the benchmark scheme ((ch1+ch2), (ch3+ch4)) and others in gapped and/or interleaved spectral channelization in material specific imaging, while the interleaved scheme (ch1, ch4)+(ch2, ch3) performs the best in virtual monochromatic imaging. Notably, only about half x-ray dose is utilized in the scheme (ch1, ch4) for image formation. Under realistic detector spectral response, the difference in imaging performance over all spectral channelization schemes diminishes, along with degradation in each scheme's individual performance. The results suggest that (i) different strategy in spectral channelization may have to be exercised in material specific imaging and virtual monochromatic imaging, respectively, and (ii) the spectral distortion in realistic detector's response due to charge-sharing, Compton scattering and fluorescent escaping should be mitigated as much as possible. Conclusion The spectral channelization schemes and associated imaging performance reported herein are novel and thus informative to the community, which may further the understanding of physical fundamentals and design principles for material decomposition based spectral imaging in photon-counting CT and other x-ray related imaging modalities. This article is protected by copyright. All rights reserved


  • High through-plane resolution CT imaging with self-supervised deep learning

    by Huiqiao Xie, Yang Lei, Tonghe Wang, Zhen Tian, Justin Roper, Jeffrey D Bradley, Walter J Curran, Xiangyang Tang, Tian Liu, Xiaofeng Yang

    CT images for radiotherapy planning are usually acquired in thick slices to reduce the imaging dose, especially for pediatric patients, and to lessen the need for contouring and treatment planning on more slices. However, low through-plane resolution may degrade the accuracy of dose calculations. In this paper, a self-supervised deep learning workflow is proposed to synthesize high through-plane resolution CT images by learning from their high in-plane resolution features. The proposed workflow was designed to facilitate neural networks to learn the mapping from low-resolution (LR) to high-resolution (HR) images in the axial plane. During the inference step, the HR sagittal and coronal images were generated by feeding two parallel-trained neural networks with the respective LR sagittal and coronal images to the trained neural networks. The CT simulation images of a cohort of 75 patients with head and neck cancer (1 mm slice thickness) and 200 CT images of a cohort of 20 lung cancer patients (3 mm slice thickness) were retrospectively investigated in a cross-validation manner. The HR images generated with the proposed method were qualitatively (visual quality, image intensity profiles and preliminary observer study) and quantitatively (mean absolute error, edge keeping index, structural similarity index measurement, information fidelity criterion and visual information fidelity in pixel domain) inspected, while taking the original CT images of the head and neck and lung cancer patients as the reference. The qualitative results showed the capability of the proposed method for generating high through-plane resolution CT images with data from both groups of cancer patients. All the improvements in the measure metrics were confirmed to be statistically significant with paired two-sample t -test analysis. The innovative point of the work is that the proposed deep learning workflow for CT image generation with high through-plane resolution in radiotherapy is self-supervised, meaning that it does not rely on ground truth CT images to train the network. In addition, the assumption that the in-plane HR information can supervise the through-plane HR generation is confirmed. We hope that this will inspire more research on this topic to further improve the through-plane resolution of medical images.


  • On the conditioning of basis materials and its impact on multimaterial decomposition‐based spectral imaging in photon‐counting CT

    by Xiangyang Tang, Yan Ren

    Purpose Material specific imaging and virtual monochromatic imaging/analysis are the two forms of spectral imaging in CT implemented via either energy‐integration or photon‐counting data acquisition. Aimed at further understanding the fundamentals and providing guidelines on its design and implementation, we quantitatively investigate the conditioning (sufficiency in dimensionality, well‐posedness in basis functions and matching of K‐edge materials) of basis materials and its impact on the performance of spectral imaging in photon‐counting CT. Materials and Methods Initially, singular value decomposition (SVD) is employed to investigate the dimensionality of material space for multi‐material decomposition based spectral imaging in photon‐counting CT over the energy range [18 150] keV. Then, the SVD is extended to study the well‐posedness of basis functions, its relationship with the dimensionality of materials to be imaged, and its impact on imaging performance. A number of phantoms are designed to mimic the soft and bony tissues in the head and contrast enhancement materials (Iodine and Gadolinium). Simulation studies, in which the geometry of photon‐counting CT is similar to a clinical CT, are carried out to evaluate and verify the proposed approach of conditioning analysis and the relationship between the conditioning of basis materials and the performance of spectral imaging in photon‐counting CT. Results The preliminary data shows that the dimensionality of biological tissues, including both soft and bony tissues, is effectively equal to two. The dimensionality increments with inclusion of K‐edge materials into the materials to be imaged. The well‐posedness of basis functions depends on the correlation between the functions and impacts the noise in material decomposition substantially, but affects the noise in virtual monochromatic imaging/analysis moderately. If a K‐edge material is in the materials to be imaged, the same K‐edge material has to be one of the basis materials, but its concentration does not affect the accuracy of material decomposition significantly. Moreover, inclusion of K‐edge material into the basis material makes the tuning of correlation among the basis functions feasible and thus improves the performance of spectral imaging in photon‐counting CT. Conclusion The extension of SVD for systematic analysis of multi‐material decomposition based spectral imaging in photon‐counting CT is of innovation and significance. In addition to providing more information on the fundamentals, the approach used in this study and the data obtained so far may provide guidelines on the implementation of spectral imaging in either photon‐counting or energy‐integration CT, as well as other x‐ray related imaging modalities such as radiography and tomosynthesis.