Latest Publications

  • Electrical Performance of Penetrating Microelectrodes Chronically Implanted in Cat Cortex

    by Sheryl R. Kane, Stuart F. Cogan, Julia Ehrlich, Timothy D. Plante, Douglas B. McCreery, Philip R. Troyk

    Penetrating microelectrode arrays with 2000 μm 2 sputtered iridium oxide (SIROF) electrode sites were implanted in cat cerebral cortex, and their long-term electrochemical performance evaluated in vivo by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and current pulsing. Measurements were made from days 33 to 328 postimplantation. The CV-defined charge storage capacity, measured at 50 mV/s, increased linearly with time over the course of implantation for two arrays and was unchanged for one array. A modest decrease in 1 kHz impedance was also observed. These results suggest an ongoing increase in the apparent electrochemical surface area of the electrodes, which is attributed to electrical leakage pathways arising from cracking of Parylene insulation observed by SEM of explanted arrays. During current pulsing with a 0.0 V interpulse bias, the electrodes readily delivered 8 nC/phase in vitro, but some channels approached or exceeded the water reduction potential during in vivo pulsing. The charge injection capacity in vivo increased linearly with the interpulse bias (0-0.6 V Ag|AgCl) from 11.5 to 21.8 nC/ph and with pulse width (150-500 μs) from 8.8 to 14 nC/ph (at 0.0 V bias). These values are lower than those determined from measurements in buffered physiological saline, emphasizing the importance of in vivo measurements in assessing chronic electrode performance. The consequence of current leakage pathways on the charge-injection measurements is also discussed.


  • Open Access

    Communication and control system for a 15-channel hermetic retinal prosthesis

    by Shawn K. Kelly, Douglas B. Shire, Jinghua Chen, Patrick Doyle, Marcus D. Gingerich, Stuart F. Cogan, William A. Drohan, Luke S. Theogarajan, John L. Wyatt, Joseph F. Rizzo


  • A Hermetic Wireless Subretinal Neurostimulator for Vision Prostheses

    by Shawn K. Kelly, Douglas B. Shire, Jinghua Chen, Patrick Doyle, Marcus D. Gingerich, Stuart F. Cogan, William A. Drohan, Sonny Behan, Luke Theogarajan, John L. Wyatt, et al.

    A miniaturized, hermetically encased, wirelessly operated retinal prosthesis has been developed for preclinical studies in the Yucatan minipig, and includes several design improvements over our previously reported device. The prosthesis attaches conformally to the outside of the eye and electrically drives a microfabricated thin-film polyimide array of sputtered iridium oxide film electrodes. This array is implanted into the subretinal space using a customized ab externo surgical technique. The implanted device includes a hermetic titanium case containing a 15-channel stimulator chip and discrete circuit components. Feedthroughs in the case connect the stimulator chip to secondary power and data receiving coils on the eye and to the electrode array under the retina. Long-term in vitro pulse testing of the electrodes projected a lifetime consistent with typical devices in industry. The final assembly was tested in vitro to verify wireless operation of the system in physiological saline using a custom RF transmitter and primary coils. Stimulation pulse strength, duration, and frequency were programmed wirelessly from a Peripheral Component Interconnect eXtensions for Instrumentation (PXI) computer. Operation of the retinal implant has been verified in two pigs for up to five and a half months by detecting stimulus artifacts generated by the implanted device.


  • Penetrating microelectrode arrays with low-impedance sputtered iridium oxide electrode coatings

    by Stuart F. Cogan, Julia Ehrlich, Timothy D. Plante, Rick Van Wagenen

    Sputtered iridium oxide (SIROF) is a candidate low-impedance coating for neural stimulation and recording electrodes. SIROF on planar substrates has exhibited a high charge-injection capacity and impedance suitable for indwelling cortical microelectrode applications. In the present work, the properties of SIROF electrode coatings deposited onto multi-shank penetrating arrays intended for intracortical and intraneural applications were examined. The charge-injection properties under constant current pulsing were evaluated for a range of pulsewidths and current densities using voltage transients to determine maximum potential excursions in an inorganic model of interstitial fluid at 37degC. The charge-injection capacity of the SIROFs was significantly improved by the use of positive potential biasing in the interpulse period, but even without bias, the SIROFs reversibly inject higher charge than other iridium oxides or platinum. Typical deliverable charge levels of 25 to 160 nC/phase were obtained with 2000 mum2 electrodes depending on pulsewidth and interpulse bias. Similar sized platinum electrodes could inject 3 to 8 nC/phase.


  • Sputtered iridium oxide films for neural stimulation electrodes

    by Stuart F. Cogan, Julia Ehrlich, Timothy D. Plante, Anton Smirnov, Douglas B. Shire, Marcus Gingerich, Joseph F. Rizzo

    Sputtered iridium oxide films (SIROFs) deposited by DC reactive sputtering from an iridium metal target have been characterized in vitro for their potential as neural recording and stimulation electrodes. SIROFs were deposited over gold metallization on flexible multielectrode arrays fabricated on thin (15 μm) polyimide substrates. SIROF thickness and electrode areas of 200–1300 nm and 1960–125,600 μm2, respectively, were investigated. The charge‐injection capacities of the SIROFs were evaluated in an inorganic interstitial fluid model in response to charge‐balanced, cathodal‐first current pulses. Charge injection capacities were measured as a function of cathodal pulse width (0.2–1 ms) and potential bias in the interpulse period (0.0 to 0.7 V vs. Ag|AgCl). Depending on the pulse parameters and electrode area, charge‐injection capacities ranged from 1–9 mC/cm2, comparable with activated iridium oxide films (AIROFs) pulsed under similar conditions. Other parameters relevant to the use of SIROF on nerve electrodes, including the thickness dependence of impedance (0.05–105 Hz) and the current necessary to maintain a bias in the interpulse region were also determined. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009


  • Top Cited Papers

    Neural Stimulation and Recording Electrodes

    by Stuart F. Cogan

    Electrical stimulation of nerve tissue and recording of neural electrical activity are the basis of emerging prostheses and treatments for spinal cord injury, stroke, sensory deficits, and neurological disorders. An understanding of the electrochemical mechanisms underlying the behavior of neural stimulation and recording electrodes is important for the development of chronically implanted devices, particularly those employing large numbers of microelectrodes. For stimulation, materials that support charge injection by capacitive and faradaic mechanisms are available. These include titanium nitride, platinum, and iridium oxide, each with certain advantages and limitations. The use of charge-balanced waveforms and maximum electrochemical potential excursions as criteria for reversible charge injection with these electrode materials are described and critiqued. Techniques for characterizing electrochemical properties relevant to stimulation and recording are described with examples of differences in the in vitro and in vivo response of electrodes.


  • The influence of electrolyte composition on thein vitrocharge-injection limits of activated iridium oxide (AIROF) stimulation electrodes

    by Stuart F Cogan, Philip R Troyk, Julia Ehrlich, Christina M Gasbarro, Timothy D Plante

    The effects of ionic conductivity and buffer concentration of electrolytes used for in vitro measurement of the charge-injection limits of activated iridium oxide (AIROF) neural stimulation electrodes have been investigated. Charge-injection limits of AIROF microelectrodes were measured in saline with a range of phosphate buffer concentrations from [PO(4)(3-)] = 0 to [PO(4)(3-)] = 103 mM and ionic conductivities from 2-28 mS cm(-1). The charge-injection limits were insensitive to the buffer concentration, but varied significantly with ionic conductivity. Using 0.4 ms cathodal current pulses at 50 Hz, the charge-injection limit increased from 0.5 mC cm(-2) to 2.1 mC cm(-2) as the conductivity was increased from 2 mS cm(-1) to 28 mS cm(-1). An explanation is proposed in which the observed dependence on ionic conductivity arises from non-uniform reduction and oxidation within the porous AIROF and from uncorrected iR-drops that result in an overestimation of the redox potential during pulsing. Conversely, slow-sweep-rate cyclic voltammograms (CVs) were sensitive to buffer concentration with the potentials of the primary Ir(3+)/Ir(4+) reduction and oxidation reactions shifting approximately 300 mV as the buffer concentration decreased from [PO(4)(3-)] = 103 mM to [PO(4)(3-)] = 0 mM. The CV response was insensitive to ionic conductivity. A comparison of in vitro AIROF charge-injection limits in commonly employed electrolyte models of extracellular fluid revealed a significant dependence on the electrolyte, with more than a factor of 4 difference under some pulsing conditions, emphasizing the need to select an electrolyte model that closely matches the conductivity and ionic composition of the in vivo environment.


  • Sputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes

    by S.F. Cogan, T.D. Plante, J. Ehrlich

    Iridium oxide films formed by electrochemical activation of iridium metal (AIROF) or by electrochemical deposition (EIROF) are being evaluated as low-impedance charge-injection coatings for neural stimulation and recording. Iridium oxide may also be deposited by reactive sputtering from iridium metal in an oxidizing plasma. The characterization of sputtered iridium oxide films (SIROFs) as coatings for nerve electrodes is reported. SIROFs were characterized by cyclic voltammetry, electrochemical impedance spectroscopy, and potential transient measurements during charge-injection. The surface morphology of the SIROF transitions from smooth to highly nodular with increasing film thickness from 80 nm to 4600 nm. Charge-injection capacities exceed 0.75 mC/cm/sup 2/ with 0.75 ms current pulses in thicker films. The SIROF was deposited on both planar and non-planar substrates and photolithographically patterned by lift-off.


  • In vivo and In vitro Differences in the Charge-injection and Electrochemical Properties of Iridium Oxide Electrodes

    by Stuart F. Cogan

    The electrochemical response of activated iridium oxide (AIROF) electrodes implanted acutely in the subretinal space of the rabbit is compared with in vitro measurements in model electrolytes. Voltage transients during current pulsing, cyclic voltammetry, impedance spectroscopy and open-circuit potential measurements were compared. Subretinal charge injection by constant current pulsing required significantly greater driving voltages due to both higher access resistances (iR) and large electrochemical polarization across the electrode-tissue interface. Differences in the in vivo and in vitro open-circuit potentials were also noted. The data suggest that the buffering capacity in the subretinal space, at least in the acute study, is higher than that in inorganic models of interstitial fluid. Possible origins of these differences in terms of electrode-tissue interactions are discussed


  • In vivo and In vitro Differences in the Charge-injection and Electrochemical Properties of Iridium Oxide Electrodes

    by Stuart F. Cogan

    The electrochemical response of activated iridium oxide (AIROF) electrodes implanted acutely in the subretinal space of the rabbit is compared with in vitro measurements in model electrolytes. Voltage transients during current pulsing, cyclic voltammetry, impedance spectroscopy and open-circuit potential measurements were compared. Subretinal charge injection by constant current pulsing required significantly greater driving voltages due to both higher access resistances (iR) and large electrochemical polarization across the electrode-tissue interface. Differences in the in vivo and in vitro open-circuit potentials were also noted. The data suggest that the buffering capacity in the subretinal space, at least in the acute study, is higher than that in inorganic models of interstitial fluid. Possible origins of these differences in terms of electrode-tissue interactions are discussed