Wenping Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wenping Wang has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Hong Ding
Department of Ultrasound, Huashan Hospital, Fudan University, Shanghai 200040, China
5 shared publications Yi Dong
Department of Ultrasound, Zhongshan Hospital, Fudan University, China
5 shared publicationsFeng Mao
Department of Ultrasound, Zhongshan Hospital, Fudan University, China
4 shared publicationsJiaying Cao
4 shared publications- Bei-Jian Huang
Department of Ultrasound Zhongshan Hospital Fudan University Shanghai China
3 shared publications - Chao-Lun Li
Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China.
3 shared publications
Latest Publications
- Open Access
- 1 January 2017
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 43, S162-S163
Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision Making Approach
- 1 January 2017
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 43, S162-S163
Open AccessContrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision Making Approach
- 1 January 2017
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 43, S96
Elastpq in Differentiating Benign and Malignant Focal Liver Lesions
- 1 January 2017
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 43, S96
Elastpq in Differentiating Benign and Malignant Focal Liver Lesions
- 1 February 2016
- Vol. 21 (114) , 89-98
Xanthogranulomatous cholecystitis: contrast-enhanced ultrasound features and differential diagnosis from wall-thickening gallbladder carcinoma.
The purpose of this study is to evaluate the value of contrast-enhanced ultrasound (CEUS) in differential diagnosis of Xanthogranulomatous cholecystitis (XGC). Patients of 17 XGCs and 43 wall-thickening gallbladder carcinomas (GBCs) were enrolled in this study. Firstly, we compared the ability of conventional ultrasound (CUS) and CEUS in detecting gallbladder (GB) features. Secondly, XGCs and GBCs features were compared on CEUS. Finally, all valuable indicators were ranked by Odds ratio. Significant differences were found in detecting GB wall thickness, GB stones, and hypoechoic nodules frequencies by CEUS and CUS. The mean GB wall thickness was 8.53 mm on CEUS, whereas the thickness measured 9.47 mm on CUS (p=0.011). GB stones and hypoechoic nodules were detected in 43 cases (71.7%) and 21 cases (30.0%) on CEUS, respectively, compared to 29 cases (48.3%) and 8 cases (13.3%) on CUS (p=0.009, p=0.027), respectively. Secondly, hypoenhancement time was longer in XGC (mean 78.9 s) than in GBC (mean 56.0 s) (p=0.002). Diffuse GB wall thickening, continuous inner wall, and hypoechoic nodules in the GB wall were observed in 12 patients (70.6%), 12 patients (70.6%) and 10 patients (58.8%) with XGC, respectively, compared to detection in 10 patients (23.3%), 4 patients (9.3%) and 11 patients (25.6%) by GBC (p=0.001, p=0.000 and p=0.015), respectively. Thirdly, the continuous inner wall was the most valuable indicator, with ORs of 23.4. The second valuable indicator was hypoenhancement time >80.5 s, with ORs of 11.9. CEUS demonstrated superior detection of GB wall thickness, GB stone and hypoechoic nodules compared to CUS. A continuous inner wall, hypoenhancement times greater than 80.5 s, diffuse thickening, and hypoechoic nodules were valuable indicators in XGCs.
- 1 February 2016
- Vol. 21 (114) , 89-98
Xanthogranulomatous cholecystitis: contrast-enhanced ultrasound features and differential diagnosis from wall-thickening gallbladder carcinoma.
The purpose of this study is to evaluate the value of contrast-enhanced ultrasound (CEUS) in differential diagnosis of Xanthogranulomatous cholecystitis (XGC). Patients of 17 XGCs and 43 wall-thickening gallbladder carcinomas (GBCs) were enrolled in this study. Firstly, we compared the ability of conventional ultrasound (CUS) and CEUS in detecting gallbladder (GB) features. Secondly, XGCs and GBCs features were compared on CEUS. Finally, all valuable indicators were ranked by Odds ratio. Significant differences were found in detecting GB wall thickness, GB stones, and hypoechoic nodules frequencies by CEUS and CUS. The mean GB wall thickness was 8.53 mm on CEUS, whereas the thickness measured 9.47 mm on CUS (p=0.011). GB stones and hypoechoic nodules were detected in 43 cases (71.7%) and 21 cases (30.0%) on CEUS, respectively, compared to 29 cases (48.3%) and 8 cases (13.3%) on CUS (p=0.009, p=0.027), respectively. Secondly, hypoenhancement time was longer in XGC (mean 78.9 s) than in GBC (mean 56.0 s) (p=0.002). Diffuse GB wall thickening, continuous inner wall, and hypoechoic nodules in the GB wall were observed in 12 patients (70.6%), 12 patients (70.6%) and 10 patients (58.8%) with XGC, respectively, compared to detection in 10 patients (23.3%), 4 patients (9.3%) and 11 patients (25.6%) by GBC (p=0.001, p=0.000 and p=0.015), respectively. Thirdly, the continuous inner wall was the most valuable indicator, with ORs of 23.4. The second valuable indicator was hypoenhancement time >80.5 s, with ORs of 11.9. CEUS demonstrated superior detection of GB wall thickness, GB stone and hypoechoic nodules compared to CUS. A continuous inner wall, hypoenhancement times greater than 80.5 s, diffuse thickening, and hypoechoic nodules were valuable indicators in XGCs.
- 1 October 2014
- Vol. 18 (99) , 179-88
The value of contrast-enhanced ultrasound (CEUS) in detecting minute renal cell carcinoma.
To investigate the value of contrast-enhanced ultrasound (CEUS) in the detection of minute renal cell carcinoma (MRCC) compared to conventional ultrasound (US) and contrast-enhanced computed tomography (CECT). Thirty-eight consecutive patients with 38 histopathologically proven MRCCs (≦15 mm) were enrolled in our study. CEUS and CECT were available in 38 and 24 patients, respectively. The features of CEUS were evaluated and compared to conventional ultrasound (US) and CECT. Ten (26.3%) tumors could not be detected by conventional US, while all tumors were detected by CEUS. The features of tumor border, blood flow, and echogenicity had significant difference between conventional US and CEUS (p=0.000, p=0.003, and p=0.012, respectively). The score of visibility of tumors by CEUS was significant higher than that of conventional US. The sensitivity, specificity, and accuracy of conventional US and CEUS in evaluating tumor necrosis were 42.9%, 50%, and 47.4% vs. 85.7%, 95.8%, and 92.1%, respectively. The enhancement features of MRCC including tumor vascularization, homogeneity, and border had no significant difference between CEUS and CECT (all p>0.05). On CEUS, synchronous-in (89.5%), hypervascular (84.2%), and fast-out (71.1%) were the most commonly observed enhancement characteristics for MRCC. CEUS performs better in detecting MRCC than conventional US, and it has the same capabilities in reflecting the enhanced features of MRCC as CECT.
- 1 October 2014
- Vol. 18 (99) , 179-88
The value of contrast-enhanced ultrasound (CEUS) in detecting minute renal cell carcinoma.
To investigate the value of contrast-enhanced ultrasound (CEUS) in the detection of minute renal cell carcinoma (MRCC) compared to conventional ultrasound (US) and contrast-enhanced computed tomography (CECT). Thirty-eight consecutive patients with 38 histopathologically proven MRCCs (≦15 mm) were enrolled in our study. CEUS and CECT were available in 38 and 24 patients, respectively. The features of CEUS were evaluated and compared to conventional ultrasound (US) and CECT. Ten (26.3%) tumors could not be detected by conventional US, while all tumors were detected by CEUS. The features of tumor border, blood flow, and echogenicity had significant difference between conventional US and CEUS (p=0.000, p=0.003, and p=0.012, respectively). The score of visibility of tumors by CEUS was significant higher than that of conventional US. The sensitivity, specificity, and accuracy of conventional US and CEUS in evaluating tumor necrosis were 42.9%, 50%, and 47.4% vs. 85.7%, 95.8%, and 92.1%, respectively. The enhancement features of MRCC including tumor vascularization, homogeneity, and border had no significant difference between CEUS and CECT (all p>0.05). On CEUS, synchronous-in (89.5%), hypervascular (84.2%), and fast-out (71.1%) were the most commonly observed enhancement characteristics for MRCC. CEUS performs better in detecting MRCC than conventional US, and it has the same capabilities in reflecting the enhanced features of MRCC as CECT.
- 1 May 2013
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 39 (5) , S80
Comprehensive Ultrasound Diagnosis Value of Hepatocellular Adenoma
- 1 May 2013
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 39 (5) , S80
Comprehensive Ultrasound Diagnosis Value of Hepatocellular Adenoma
- 1 May 2012
- Published by Wolters Kluwer Health in Zhonghua gan zang bing za zhi = Zhonghua ganzangbing zazhi = Chinese journal of hepatology
- Vol. 20 (5) , 386-9
[Real-time elastography for quantitative assessment of liver fibrosis in a rat model].
To investigate the feasibility of real-time elastography for quantitative evaluation of liver fibrosis in a rat model. A total of 70 male Wistar rats were included in the group for dimethylnitrosamine (DMN)-induced liver injury, and 10 saline-injected rats were used as normal control. Hepatic injury was induced by a single intraperitoneal injection of DMN at a dose of 50 mg/kg of body weight. Nine or ten rats in the group with DNM injected and one or two rats in the normal control group were randomly selected and sacrificed at each of the following post-injection time: day 5, 7, 10, 14, 21, 24, and 28. And their livers were taken for pathology analysis. All the rats underwent real-time elastography before sacrificed in order to acquire area ratio of low-strain region (% AREA) and liver fibrosis index (LF index) which were compared with the stage of liver fibrosis and grade of necroinflammatory pathologically. By the different data, Spearman correlation analysis, rank-sum test or receiver operating characteristic curve was used. Among 58 successfully modeled rats, there were nine, 13, 14 and 12 rats of S1, S2, S3 and S4 liver fibrosis on pathology, respectively, which were with or without mild necroinflammatory. The other 10 rats were found to be S0 with severe necroinflammatory. Values of LF index and % AREA both increased with liver fibrosis stage (P less than 0.05). There was certain correlation between LF index and liver fibrosis stage (r=0.643, P=0.000), so was % AREA and liver fibrosis stage (r=0.662, P=0.000). As for LF index, Areas under the receiver operating characteristic curve (Az) was 0.943, 0.890, 0.743 and 0.821 for the diagnosis of hepatic fibrosis S1 or higher, S2 or higher, S3 or higher and S4, respectively; as for % AREA, they were 0.948, 0.883, 0.772 and 0.842, respectively. However, we found a significant difference for LF index or % AREA between S0 with and without severe inflammatory activity rats (P=0.005 and P=0.017). Real-time elastography is available for quantitative assessment of liver fibrosis in rats induced by DMN, but severe inflammatory activity can affect its accuracy.
- 1 May 2012
- Published by Wolters Kluwer Health in Zhonghua gan zang bing za zhi = Zhonghua ganzangbing zazhi = Chinese journal of hepatology
- Vol. 20 (5) , 386-9
[Real-time elastography for quantitative assessment of liver fibrosis in a rat model].
To investigate the feasibility of real-time elastography for quantitative evaluation of liver fibrosis in a rat model. A total of 70 male Wistar rats were included in the group for dimethylnitrosamine (DMN)-induced liver injury, and 10 saline-injected rats were used as normal control. Hepatic injury was induced by a single intraperitoneal injection of DMN at a dose of 50 mg/kg of body weight. Nine or ten rats in the group with DNM injected and one or two rats in the normal control group were randomly selected and sacrificed at each of the following post-injection time: day 5, 7, 10, 14, 21, 24, and 28. And their livers were taken for pathology analysis. All the rats underwent real-time elastography before sacrificed in order to acquire area ratio of low-strain region (% AREA) and liver fibrosis index (LF index) which were compared with the stage of liver fibrosis and grade of necroinflammatory pathologically. By the different data, Spearman correlation analysis, rank-sum test or receiver operating characteristic curve was used. Among 58 successfully modeled rats, there were nine, 13, 14 and 12 rats of S1, S2, S3 and S4 liver fibrosis on pathology, respectively, which were with or without mild necroinflammatory. The other 10 rats were found to be S0 with severe necroinflammatory. Values of LF index and % AREA both increased with liver fibrosis stage (P less than 0.05). There was certain correlation between LF index and liver fibrosis stage (r=0.643, P=0.000), so was % AREA and liver fibrosis stage (r=0.662, P=0.000). As for LF index, Areas under the receiver operating characteristic curve (Az) was 0.943, 0.890, 0.743 and 0.821 for the diagnosis of hepatic fibrosis S1 or higher, S2 or higher, S3 or higher and S4, respectively; as for % AREA, they were 0.948, 0.883, 0.772 and 0.842, respectively. However, we found a significant difference for LF index or % AREA between S0 with and without severe inflammatory activity rats (P=0.005 and P=0.017). Real-time elastography is available for quantitative assessment of liver fibrosis in rats induced by DMN, but severe inflammatory activity can affect its accuracy.
- 1 February 2012
- Vol. 125 (4) , 652-6
Quantitative evaluation of acute renal failure in rabbits with contrast-enhanced ultrasound.
Assessment of perfusion in the early period of acute renal failure (ARF) is important, and can not be made by conventional ultrasound. The aim of this study was to prospectively test in a rabbit ARF model whether real-time contrast-enhanced ultrasound (CEUS) can quantitatively evaluate the hemodynamic changes of renal cortex in the early period. The model of ARF was induced in 30 healthy New Zealand white rabbits (2.5 - 3.0 kg), by intramuscular injection of 50% glycerin solution (12 ml/kg). CEUS were performed on right kidneys before, 6 and 24 hours after glycerin injection. CEUS quantitative indexes were measured in renal cortex using QLAB software. Comparisons between different stages were performed using paired t test. The sensitivity of CEUS in diagnosing ARF was compared with blood serum urea nitrogen (BUN), serum creatinine (SCr) level and color Doppler flow imaging (CDFI). Among quantitative indexes, time to peak (TTP) and area under curve (AUC) increased significantly from (5.86 ± 2.57) seconds and (124.4 ± 46.7) dB·s before glycerin injection to (7.66 ± 2.05) seconds and (288.1 ± 64.9) dB·s 6 hours after injection (P < 0.05). Slope rate of ascending curve (A) and descending curve (a) decreased slightly from (3.00 ± 1.22) dB/s and (0.19 ± 0.15) 1/s to (2.80 ± 1.45) dB·s and (0.09 ± 0.02) 1/s (P < 0.05). Twenty-four hours later, only AUC increased significantly from (124.4 ± 46.7) dB·s to (466.2 ± 52.2) dB·s (P < 0.05). Quantitative indexes of CEUS might be useful in predicting the hemodynamic changes of renal cortex in the early six hours of ARF model.
- 1 February 2012
- Vol. 125 (4) , 652-6
Quantitative evaluation of acute renal failure in rabbits with contrast-enhanced ultrasound.
Assessment of perfusion in the early period of acute renal failure (ARF) is important, and can not be made by conventional ultrasound. The aim of this study was to prospectively test in a rabbit ARF model whether real-time contrast-enhanced ultrasound (CEUS) can quantitatively evaluate the hemodynamic changes of renal cortex in the early period. The model of ARF was induced in 30 healthy New Zealand white rabbits (2.5 - 3.0 kg), by intramuscular injection of 50% glycerin solution (12 ml/kg). CEUS were performed on right kidneys before, 6 and 24 hours after glycerin injection. CEUS quantitative indexes were measured in renal cortex using QLAB software. Comparisons between different stages were performed using paired t test. The sensitivity of CEUS in diagnosing ARF was compared with blood serum urea nitrogen (BUN), serum creatinine (SCr) level and color Doppler flow imaging (CDFI). Among quantitative indexes, time to peak (TTP) and area under curve (AUC) increased significantly from (5.86 ± 2.57) seconds and (124.4 ± 46.7) dB·s before glycerin injection to (7.66 ± 2.05) seconds and (288.1 ± 64.9) dB·s 6 hours after injection (P < 0.05). Slope rate of ascending curve (A) and descending curve (a) decreased slightly from (3.00 ± 1.22) dB/s and (0.19 ± 0.15) 1/s to (2.80 ± 1.45) dB·s and (0.09 ± 0.02) 1/s (P < 0.05). Twenty-four hours later, only AUC increased significantly from (124.4 ± 46.7) dB·s to (466.2 ± 52.2) dB·s (P < 0.05). Quantitative indexes of CEUS might be useful in predicting the hemodynamic changes of renal cortex in the early six hours of ARF model.