Chao-Lun Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chao-Lun Li has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Bei-Jian Huang
Department of Ultrasound Zhongshan Hospital Fudan University Shanghai China
4 shared publications - Hong Ding
Department of Ultrasound, Huashan Hospital, Fudan University, Shanghai 200040, China
3 shared publications - Wenping Wang
Department of Ultrasound, Zhongshan Hospital, Fudan University, China
3 shared publications Chunchun Huang
School of Communication and Information Engineering, Shanghai University, 200444 Shanghai, China
2 shared publicationsHai-Xia Yuan
2 shared publicationsZheng-Biao Ji
2 shared publications
Latest Publications
- 30 August 2018
- Published by SRUMB - Romanian Society for Ultrasonography in Medicine and Biology in Medical Ultrasonography
- Vol. 20 (3) , 392-395
Contrast enhanced imaging features of liver metastasis from a meningeal solitary fibrous tumor: a case report
A solitary fibrous tumor seldom originates from the meninges, and the accuracy of imaging modalities in the diagnosis of meningeal SFT metastasisis is perlexing. Contrast enhanced imaging modalities, such as contrast enhanced ultrasound and contrast enhanced magnetic resonance imaging are valuable in the differential diagnosis of hepatic neoplasms. This case report demonstrated the contrast enhanced ultrasound and enhanced magnetic resonance imaging features of one case of liver metastasis from a menigeal solitary fibrous tumor.
- 30 August 2018
- Published by SRUMB - Romanian Society for Ultrasonography in Medicine and Biology in Medical Ultrasonography
- Vol. 20 (3) , 392-395
Contrast enhanced imaging features of liver metastasis from a meningeal solitary fibrous tumor: a case report
A solitary fibrous tumor seldom originates from the meninges, and the accuracy of imaging modalities in the diagnosis of meningeal SFT metastasisis is perlexing. Contrast enhanced imaging modalities, such as contrast enhanced ultrasound and contrast enhanced magnetic resonance imaging are valuable in the differential diagnosis of hepatic neoplasms. This case report demonstrated the contrast enhanced ultrasound and enhanced magnetic resonance imaging features of one case of liver metastasis from a menigeal solitary fibrous tumor.
- 1 February 2016
- Vol. 21 (114) , 89-98
Xanthogranulomatous cholecystitis: contrast-enhanced ultrasound features and differential diagnosis from wall-thickening gallbladder carcinoma.
The purpose of this study is to evaluate the value of contrast-enhanced ultrasound (CEUS) in differential diagnosis of Xanthogranulomatous cholecystitis (XGC). Patients of 17 XGCs and 43 wall-thickening gallbladder carcinomas (GBCs) were enrolled in this study. Firstly, we compared the ability of conventional ultrasound (CUS) and CEUS in detecting gallbladder (GB) features. Secondly, XGCs and GBCs features were compared on CEUS. Finally, all valuable indicators were ranked by Odds ratio. Significant differences were found in detecting GB wall thickness, GB stones, and hypoechoic nodules frequencies by CEUS and CUS. The mean GB wall thickness was 8.53 mm on CEUS, whereas the thickness measured 9.47 mm on CUS (p=0.011). GB stones and hypoechoic nodules were detected in 43 cases (71.7%) and 21 cases (30.0%) on CEUS, respectively, compared to 29 cases (48.3%) and 8 cases (13.3%) on CUS (p=0.009, p=0.027), respectively. Secondly, hypoenhancement time was longer in XGC (mean 78.9 s) than in GBC (mean 56.0 s) (p=0.002). Diffuse GB wall thickening, continuous inner wall, and hypoechoic nodules in the GB wall were observed in 12 patients (70.6%), 12 patients (70.6%) and 10 patients (58.8%) with XGC, respectively, compared to detection in 10 patients (23.3%), 4 patients (9.3%) and 11 patients (25.6%) by GBC (p=0.001, p=0.000 and p=0.015), respectively. Thirdly, the continuous inner wall was the most valuable indicator, with ORs of 23.4. The second valuable indicator was hypoenhancement time >80.5 s, with ORs of 11.9. CEUS demonstrated superior detection of GB wall thickness, GB stone and hypoechoic nodules compared to CUS. A continuous inner wall, hypoenhancement times greater than 80.5 s, diffuse thickening, and hypoechoic nodules were valuable indicators in XGCs.
- 1 February 2016
- Vol. 21 (114) , 89-98
Xanthogranulomatous cholecystitis: contrast-enhanced ultrasound features and differential diagnosis from wall-thickening gallbladder carcinoma.
The purpose of this study is to evaluate the value of contrast-enhanced ultrasound (CEUS) in differential diagnosis of Xanthogranulomatous cholecystitis (XGC). Patients of 17 XGCs and 43 wall-thickening gallbladder carcinomas (GBCs) were enrolled in this study. Firstly, we compared the ability of conventional ultrasound (CUS) and CEUS in detecting gallbladder (GB) features. Secondly, XGCs and GBCs features were compared on CEUS. Finally, all valuable indicators were ranked by Odds ratio. Significant differences were found in detecting GB wall thickness, GB stones, and hypoechoic nodules frequencies by CEUS and CUS. The mean GB wall thickness was 8.53 mm on CEUS, whereas the thickness measured 9.47 mm on CUS (p=0.011). GB stones and hypoechoic nodules were detected in 43 cases (71.7%) and 21 cases (30.0%) on CEUS, respectively, compared to 29 cases (48.3%) and 8 cases (13.3%) on CUS (p=0.009, p=0.027), respectively. Secondly, hypoenhancement time was longer in XGC (mean 78.9 s) than in GBC (mean 56.0 s) (p=0.002). Diffuse GB wall thickening, continuous inner wall, and hypoechoic nodules in the GB wall were observed in 12 patients (70.6%), 12 patients (70.6%) and 10 patients (58.8%) with XGC, respectively, compared to detection in 10 patients (23.3%), 4 patients (9.3%) and 11 patients (25.6%) by GBC (p=0.001, p=0.000 and p=0.015), respectively. Thirdly, the continuous inner wall was the most valuable indicator, with ORs of 23.4. The second valuable indicator was hypoenhancement time >80.5 s, with ORs of 11.9. CEUS demonstrated superior detection of GB wall thickness, GB stone and hypoechoic nodules compared to CUS. A continuous inner wall, hypoenhancement times greater than 80.5 s, diffuse thickening, and hypoechoic nodules were valuable indicators in XGCs.
- 1 September 2015
- Published by Elsevier in Ultrasonics
- Vol. 62, 253-262
Quantification of carotid plaque elasticity and intraplaque neovascularization using contrast-enhanced ultrasound and image registration-based elastography
- 1 September 2015
- Published by Elsevier in Ultrasonics
- Vol. 62, 253-262
Quantification of carotid plaque elasticity and intraplaque neovascularization using contrast-enhanced ultrasound and image registration-based elastography
- 1 February 2008
- Vol. 30 (1) , 31-4
[Diagnosis of atypical liver abscesses with real-time contrast-enhanced ultrasound].
To investigate the value of real-time harmonic contrast-enhanced ultrasound (CEUS) in the diagnosis of atypical liver abscesses. We used Technos DU8 system with CEUS technique to examine 32 patients with suspected liver masses. Mechanical index was set at 0.08- 0.11. The contrast agent SonoVue was injected as a bolus (2.4 ml, < 5s) in the antecubital vein. A total of 36 lesions were studied in 32 patients, including 30 patients with single nodule and 2 patients with multiple nodules. All lesions with liver abscess were confirmed by biopsy. The whole-enhanced pattern in all lesions was clearly displayed in the arterial phase after the administration of SonoVue. The mean time of the beginning enhancement was (14.48 +/- 3.62) s, the mean peak enhancement time was (22.92 +/- 4.35) s, and the mean time of hypoechoic appearance of lesion was (80.30 +/- 35.30) s. The lesions with hypoechoic pattern (37.5%, 12/32) and isoechoic pattern (62.5%, 20/32) in the portal phase were detected by CEUS. The characteristic sign with honeycomb pattern on CEUS was shown in 30 (93.8%) liver abscess lesions. CEUS is valuable in the diagnosis of atypical liver abscesses.
- 1 February 2008
- Vol. 30 (1) , 31-4
[Diagnosis of atypical liver abscesses with real-time contrast-enhanced ultrasound].
To investigate the value of real-time harmonic contrast-enhanced ultrasound (CEUS) in the diagnosis of atypical liver abscesses. We used Technos DU8 system with CEUS technique to examine 32 patients with suspected liver masses. Mechanical index was set at 0.08- 0.11. The contrast agent SonoVue was injected as a bolus (2.4 ml, < 5s) in the antecubital vein. A total of 36 lesions were studied in 32 patients, including 30 patients with single nodule and 2 patients with multiple nodules. All lesions with liver abscess were confirmed by biopsy. The whole-enhanced pattern in all lesions was clearly displayed in the arterial phase after the administration of SonoVue. The mean time of the beginning enhancement was (14.48 +/- 3.62) s, the mean peak enhancement time was (22.92 +/- 4.35) s, and the mean time of hypoechoic appearance of lesion was (80.30 +/- 35.30) s. The lesions with hypoechoic pattern (37.5%, 12/32) and isoechoic pattern (62.5%, 20/32) in the portal phase were detected by CEUS. The characteristic sign with honeycomb pattern on CEUS was shown in 30 (93.8%) liver abscess lesions. CEUS is valuable in the diagnosis of atypical liver abscesses.
- 1 March 2005
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 24 (3) , 285-297
Imaging of Focal Liver Lesions
- 1 March 2005
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 24 (3) , 285-297
Imaging of Focal Liver Lesions