Ye Pu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ye Pu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Christophe Moser
Ecole Polytechnique Federale de Lausanne (Switzerland)
1 shared publication Demetri Psaltis
Department of Electrical Engineering
1 shared publication- Demetri Psaltis
Optics Laboratory (LO), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
1 shared publication Giulia Panusa
Ecole Polytechnique Federale de Lausanne (Switzerland)
1 shared publication- Hui Meng
State University of New York at Buffalo
1 shared publication - Jieping Wang
School of Chemistry and Chemical Engineering Nanjing University of Science and Technology Nanjing 210094 China
1 shared publication
Latest Publications
- 28 September 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10735, 1073504
Photoinitiator-free laser fabrication of ultra-compact, low-loss waveguides in polydimethylsiloxane
Owing to its excellent elasticity, wide spectral range of transparency, and outstanding chemical and thermal stability, polydimethylsiloxane (PDMS) is an elastomer of great technological importance, being widely used in the fabrication of microfluidic and optofluidic devices in particular. Compact, low loss optical waveguides are crucial in such devices for a dense integration of optical functionalities. Compared with photolithographic methods, multiphoton laser direct writing through photopolymerization has shown great promise in the fabrication of three-dimensional (3D) optical waveguides in PDMS without the limit of planar structures. Here we demonstrate a multiphoton laser direct writing process that produces low-loss, ultra-compact waveguides in PDMS. The fabrication employs a self-initiated multiphoton polymerization of phenylacetylene infused in PDMS without additional photoinitiator. The elimination of the photoinitiator results in an excellent refractive index homogeneity and thus a low propagation loss due to scattering, as well as a greater biocompatibility by involving the fewest possible chemicals (monomer only) in the polymerization reaction. Our characterizations show that the waveguides fabricated as such are on average 1.3 µm wide with a refractive index contrast of 0.06 and a propagation loss of 0.03 dB/cm in the spectral band of 650-700 nm. Our technique will enable a broad range of applications spanning from wearable photonics to chip-scale optical interconnects.
- 28 September 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10735, 1073504
Photoinitiator-free laser fabrication of ultra-compact, low-loss waveguides in polydimethylsiloxane
Owing to its excellent elasticity, wide spectral range of transparency, and outstanding chemical and thermal stability, polydimethylsiloxane (PDMS) is an elastomer of great technological importance, being widely used in the fabrication of microfluidic and optofluidic devices in particular. Compact, low loss optical waveguides are crucial in such devices for a dense integration of optical functionalities. Compared with photolithographic methods, multiphoton laser direct writing through photopolymerization has shown great promise in the fabrication of three-dimensional (3D) optical waveguides in PDMS without the limit of planar structures. Here we demonstrate a multiphoton laser direct writing process that produces low-loss, ultra-compact waveguides in PDMS. The fabrication employs a self-initiated multiphoton polymerization of phenylacetylene infused in PDMS without additional photoinitiator. The elimination of the photoinitiator results in an excellent refractive index homogeneity and thus a low propagation loss due to scattering, as well as a greater biocompatibility by involving the fewest possible chemicals (monomer only) in the polymerization reaction. Our characterizations show that the waveguides fabricated as such are on average 1.3 µm wide with a refractive index contrast of 0.06 and a propagation loss of 0.03 dB/cm in the spectral band of 650-700 nm. Our technique will enable a broad range of applications spanning from wearable photonics to chip-scale optical interconnects.
- 29 November 2007
- Published by Optica Publishing Group in Applied Optics
- Vol. 47 (4) , A103-A110
Harmonic holography: a new holographic principle
The process of second harmonic generation (SHG) has a unique property of forming a sharp optical contrast between noncentrosymmetric crystalline materials and other types of material, which is a highly valuable asset for contrast microscopy. The coherent signal obtained through SHG also allows for the recording of holograms at high spatial and temporal resolution, enabling whole-field four-dimensional microscopy for highly dynamic microsystems and nanosystems. Here we describe a new holographic principle, harmonic holography , which records holograms between independently generated second harmonic signals and reference. We experimentally demonstrate this technique with digital holographic recording of second harmonic signals upconverted from an ensemble of second harmonic generating nanocrystal clusters under femtosecond laser excitation. Our results show that harmonic holography is uniquely suited for ultrafast four-dimensional contrast microscopy.- 29 November 2007
- Published by Optica Publishing Group in Applied Optics
- Vol. 47 (4) , A103-A110
Harmonic holography: a new holographic principle
The process of second harmonic generation (SHG) has a unique property of forming a sharp optical contrast between noncentrosymmetric crystalline materials and other types of material, which is a highly valuable asset for contrast microscopy. The coherent signal obtained through SHG also allows for the recording of holograms at high spatial and temporal resolution, enabling whole-field four-dimensional microscopy for highly dynamic microsystems and nanosystems. Here we describe a new holographic principle, harmonic holography , which records holograms between independently generated second harmonic signals and reference. We experimentally demonstrate this technique with digital holographic recording of second harmonic signals upconverted from an ensemble of second harmonic generating nanocrystal clusters under femtosecond laser excitation. Our results show that harmonic holography is uniquely suited for ultrafast four-dimensional contrast microscopy.- 20 December 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (36) , 7697-7708
Four-dimensional dynamic flow measurement by holographic particle image velocimetry
The ultimate goal of holographic particle image velocimetry (HPIV) is to provide space- and time-resolved measurement of complex flows. Recent new understanding of holographic imaging of small particles, pertaining to intrinsic aberration and noise in particular, has enabled us to elucidate fundamental issues in HPIV and implement a new HPIV system. This system is based on our previously reported off-axis HPIV setup, but the design is optimized by incorporating our new insights of holographic particle imaging characteristics. Furthermore, the new system benefits from advanced data processing algorithms and distributed parallel computing technology. Because of its robustness and efficiency, for the first time to our knowledge, the goal of both temporally and spatially resolved flow measurements becomes tangible. We demonstrate its temporal measurement capability by a series of phase-locked dynamic measurements of instantaneous three-dimensional, three-component velocity fields in a highly three-dimensional vortical flow—the flow past a tab.
- 20 December 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (36) , 7697-7708
Four-dimensional dynamic flow measurement by holographic particle image velocimetry
The ultimate goal of holographic particle image velocimetry (HPIV) is to provide space- and time-resolved measurement of complex flows. Recent new understanding of holographic imaging of small particles, pertaining to intrinsic aberration and noise in particular, has enabled us to elucidate fundamental issues in HPIV and implement a new HPIV system. This system is based on our previously reported off-axis HPIV setup, but the design is optimized by incorporating our new insights of holographic particle imaging characteristics. Furthermore, the new system benefits from advanced data processing algorithms and distributed parallel computing technology. Because of its robustness and efficiency, for the first time to our knowledge, the goal of both temporally and spatially resolved flow measurements becomes tangible. We demonstrate its temporal measurement capability by a series of phase-locked dynamic measurements of instantaneous three-dimensional, three-component velocity fields in a highly three-dimensional vortical flow—the flow past a tab.