Arunn Narasimhan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Arunn Narasimhan has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- B. V. K. Reddy
University of Pittsburgh, Pittsburgh, PA
5 shared publications - Kaushal Kumar Jha
Mahindra & Mahindra Ltd
4 shared publications - Ajith Joseph
Indian Inst Technol Madras, Dept Mech Engn, Chennai 600036, Tamil Nadu, India
2 shared publications K. Sumithra Raju
Heat Transfer and Thermal Power Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, Tamil Nadu 600036, India
2 shared publicationsRamanathan Vishnampet
Heat Transfer and Thermal Power Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai 600 036, India
2 shared publications- Shrinivas Vibhute
Indian Institute of Technology Madras
2 shared publications
Latest Publications
- 19 December 2024
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (1) , e3893
Effects of Congestion in Human Lung Investigated Using Dual‐Scale Porous Medium Models
Chronic obstructive pulmonary disease (COPD) is a primary chronic respiratory disease associated with pulmonary congestion that restricts airflow and thereby affects the exchange of gases between the alveoli and the blood capillaries in the lungs. Dual scale—global and local—porous medium models have been developed and reported in this work, to study the effects of air‐side congestion on the blood‐oxygen content in the alveolar region of the human lung. The human lung is model as a global, equivalent, heterogeneous porous medium comprising three zones with distinct permeabilities related to their progressively complex branching structure. Airflow for each breathing cycle is determined by solving mass and momentum transfer equations across the three porous medium zones. The congestion is introduced by appropriate modification of the porous medium properties of the zones considered. The congestion‐affected air velocity reaching Zone 3 is given as input to a separate “local model” employed at several locations of the alveoli of Zone 3. The local model determines the oxygen content in the blood flow in the capillaries of the alveoli by solving suitable mass, momentum and species transport equations. The transient simulation results performed for a long duration of multiple breathing cycles, demonstrate that a normal, healthy human lung is functional for up to 40% volume congestion or when 50% of the lung is congested to about 23.5%. Increasing congestion beyond this value, quickly—within a few hours—depletes the oxygen exchange in the blood flow of the alveolar region (of Zone 3), leading to hypoxemia. The effects of congestion progression on oxygen exchange dynamics determined through the dual‐scale porous medium modelling approach provide researchers and medical professionals with in silico predictive estimates to generate treatment strategies for chronic respiratory diseases.
- 19 December 2024
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (1) , e3893
Effects of Congestion in Human Lung Investigated Using Dual‐Scale Porous Medium Models
Chronic obstructive pulmonary disease (COPD) is a primary chronic respiratory disease associated with pulmonary congestion that restricts airflow and thereby affects the exchange of gases between the alveoli and the blood capillaries in the lungs. Dual scale—global and local—porous medium models have been developed and reported in this work, to study the effects of air‐side congestion on the blood‐oxygen content in the alveolar region of the human lung. The human lung is model as a global, equivalent, heterogeneous porous medium comprising three zones with distinct permeabilities related to their progressively complex branching structure. Airflow for each breathing cycle is determined by solving mass and momentum transfer equations across the three porous medium zones. The congestion is introduced by appropriate modification of the porous medium properties of the zones considered. The congestion‐affected air velocity reaching Zone 3 is given as input to a separate “local model” employed at several locations of the alveoli of Zone 3. The local model determines the oxygen content in the blood flow in the capillaries of the alveoli by solving suitable mass, momentum and species transport equations. The transient simulation results performed for a long duration of multiple breathing cycles, demonstrate that a normal, healthy human lung is functional for up to 40% volume congestion or when 50% of the lung is congested to about 23.5%. Increasing congestion beyond this value, quickly—within a few hours—depletes the oxygen exchange in the blood flow of the alveolar region (of Zone 3), leading to hypoxemia. The effects of congestion progression on oxygen exchange dynamics determined through the dual‐scale porous medium modelling approach provide researchers and medical professionals with in silico predictive estimates to generate treatment strategies for chronic respiratory diseases.
- 31 August 2024
- Published by Springer Nature
- p. 71-81
Numerical Study of Convection-Assisted Intra-Vitreous Drug Delivery in Human Eye
- 31 August 2024
- Published by Springer Nature
- p. 71-81
Numerical Study of Convection-Assisted Intra-Vitreous Drug Delivery in Human Eye
- 31 August 2024
- Published by Springer Nature
- p. 61-70
Numerical Modeling of the Effects of Congestion in Human Lungs
- 31 August 2024
- Published by Springer Nature
- p. 61-70
Numerical Modeling of the Effects of Congestion in Human Lungs
- 31 July 2024
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 60 (9) , 1523-1536
Dual scale porous medium model of lung congestion caused by tuberculosis
- 31 July 2024
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 60 (9) , 1523-1536
Dual scale porous medium model of lung congestion caused by tuberculosis
- 25 May 2023
- Published by Wiley in Heat Transfer
- Vol. 52 (7) , 4606-4618
Convection‐assisted intra‐vitreous drug delivery in human eye: An experimental investigation
We report an in vitro transient experimental study of the human eye to determine the effects of convection on the transport of drugs from the point of injection to the retinal surface through the fluid in the vitrectomized eye. The human eye is modeled as a glass orb of realistic proportions, and water and silicone oil mimic the vitreous fluid. In a series of experiments, the dye that is used to mimic the drug is injected at two different spots in the vitreous chamber, and its transport through the vitreous fluid mimic to the retinal surface is recorded under conditions of simple diffusion and convection‐assisted diffusion. The drug concentrations at two different spots on the retinal surface at different times are monitored. It is shown that the drug reaches all parts of the retinal surface much faster during convection‐assisted diffusion than during pure diffusion, irrespective of where it is injected in the cavity. In a snapshot, it is seen that the dye concentration reaches at the target central retinal pigmented epithelium spot in just 12 min (0.2 h) with convection‐assisted diffusion as against 12 h in pure diffusion. The steady‐state average drug concentration at the target retinal region is seen to be 56.25 times greater for the convection‐assisted drug transport than for the pure diffusion case. The results show that applying mild heat to the retinal surface by methods such as laser irradiation can induce convection‐based transport of the drug in the vitreous fluid. This method makes the drug available much faster at the target retinal region than drug transport by pure diffusion. The faster transport of the drug within the cavity can expedite the drug's effect and prevent drug loss due to delays.
- 25 May 2023
- Published by Wiley in Heat Transfer
- Vol. 52 (7) , 4606-4618
Convection‐assisted intra‐vitreous drug delivery in human eye: An experimental investigation
We report an in vitro transient experimental study of the human eye to determine the effects of convection on the transport of drugs from the point of injection to the retinal surface through the fluid in the vitrectomized eye. The human eye is modeled as a glass orb of realistic proportions, and water and silicone oil mimic the vitreous fluid. In a series of experiments, the dye that is used to mimic the drug is injected at two different spots in the vitreous chamber, and its transport through the vitreous fluid mimic to the retinal surface is recorded under conditions of simple diffusion and convection‐assisted diffusion. The drug concentrations at two different spots on the retinal surface at different times are monitored. It is shown that the drug reaches all parts of the retinal surface much faster during convection‐assisted diffusion than during pure diffusion, irrespective of where it is injected in the cavity. In a snapshot, it is seen that the dye concentration reaches at the target central retinal pigmented epithelium spot in just 12 min (0.2 h) with convection‐assisted diffusion as against 12 h in pure diffusion. The steady‐state average drug concentration at the target retinal region is seen to be 56.25 times greater for the convection‐assisted drug transport than for the pure diffusion case. The results show that applying mild heat to the retinal surface by methods such as laser irradiation can induce convection‐based transport of the drug in the vitreous fluid. This method makes the drug available much faster at the target retinal region than drug transport by pure diffusion. The faster transport of the drug within the cavity can expedite the drug's effect and prevent drug loss due to delays.
- 1 April 2020
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 151
Enhanced design for microscale distribution of drug heads for transdermal patches
- 1 April 2020
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 151
Enhanced design for microscale distribution of drug heads for transdermal patches
- 24 January 2020
- Published by ASME International in Journal of Fluids Engineering
- Vol. 142 (4)
Hydraulic Model for Accelerated Flows Through Porous Medium in the Form Drag-Dominated Regime
The pressure drop for steady uniform flows through low permeability porous media \textcolor{red}{$\left(K < 10^{-7} m^2\right)$} is predicted using the existing global Hazen-Dupuit-Darcy (HDD) hydraulic model, composed of the viscous and form-drag terms. In this work, experiments are performed to generate pressure drop data for accelerated steady flows through porous media for a wide range of low permeability $\left(10^{-9} < K < 10^{-7} m^2\right)$, low porosity \textcolor{red}{$(\phi < 0.4)$} in the form-drag dominant ($\lambda \gg 1$) flow regime. Using the data, the global spatial acceleration effect that arise due to channel cross-section variation is shown to be unaccounted for in the existing global HDD model resulting in inaccurate prediction of pressure drop, with more than $80~\%$ error in such situations. A modified hydraulic model is developed, introducing geometric parameters in the drag terms in the existing hydraulic model, to account for the acceleration effects. By comparing the results with experimental data, the proposed modified hydraulic model is shown to predict the pressure drop for accelerated flows in porous media in the form-drag dominant regime, with less than $10~\%$ error.- 24 January 2020
- Published by ASME International in Journal of Fluids Engineering
- Vol. 142 (4)
Hydraulic Model for Accelerated Flows Through Porous Medium in the Form Drag-Dominated Regime
The pressure drop for steady uniform flows through low permeability porous media \textcolor{red}{$\left(K < 10^{-7} m^2\right)$} is predicted using the existing global Hazen-Dupuit-Darcy (HDD) hydraulic model, composed of the viscous and form-drag terms. In this work, experiments are performed to generate pressure drop data for accelerated steady flows through porous media for a wide range of low permeability $\left(10^{-9} < K < 10^{-7} m^2\right)$, low porosity \textcolor{red}{$(\phi < 0.4)$} in the form-drag dominant ($\lambda \gg 1$) flow regime. Using the data, the global spatial acceleration effect that arise due to channel cross-section variation is shown to be unaccounted for in the existing global HDD model resulting in inaccurate prediction of pressure drop, with more than $80~\%$ error in such situations. A modified hydraulic model is developed, introducing geometric parameters in the drag terms in the existing hydraulic model, to account for the acceleration effects. By comparing the results with experimental data, the proposed modified hydraulic model is shown to predict the pressure drop for accelerated flows in porous media in the form-drag dominant regime, with less than $10~\%$ error.- 27 June 2018
- Published by Springer Nature
- p. 2381-2415
Heat and Mass Transfer Processes in the Eye
- 27 November 2017
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 34 (4) , e2937
Evaluation of hemodynamic performance of total cavopulmonary connection (TCPC) with porous inserts
Infants born with univentricular heart disease undergo Fontan surgery to establish separate systemic and pulmonary circulations. This surgery results in better blood circulation across a single ventricle that supplies oxygenated blood to the body and passively returns venous blood to the lungs through the total cavopulmonary connection (TCPC). Reducing the pressure drop across the TCPC during Fontan circulation helps in reducing the work load of univentricular heart, and various designs have been proposed for this purpose. The goal of this work is to analyze the effect of placing a porous insert at an appropriate position in the pulmonary artery, on the pressure drop across the TCPC. A 3D computational model of a total TCPC connection provided with a porous insert is developed and solved by finite volume method, under assumptions of steady, laminar, and Newtonian flows. The effects of the porous medium properties—porosity and permeability—across the connection, are analyzed. Compared to the no‐porous medium case, TCPC with the porous medium insert exhibits a maximum reduction of 27% in energy loss for the flow range studied. The porous medium used in TCPC connection lowers the energy dissipation by curtailing the flow recirculation zones across the connection. The influences of the diameter of the blood vessel, total cardiac output, and the thickness, permeability, and position of porous media on energy loss are analyzed. The criteria to select the porous medium properties and position for a given Fontan geometry are also determined.
- 27 November 2017
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 34 (4) , e2937
Evaluation of hemodynamic performance of total cavopulmonary connection (TCPC) with porous inserts
Infants born with univentricular heart disease undergo Fontan surgery to establish separate systemic and pulmonary circulations. This surgery results in better blood circulation across a single ventricle that supplies oxygenated blood to the body and passively returns venous blood to the lungs through the total cavopulmonary connection (TCPC). Reducing the pressure drop across the TCPC during Fontan circulation helps in reducing the work load of univentricular heart, and various designs have been proposed for this purpose. The goal of this work is to analyze the effect of placing a porous insert at an appropriate position in the pulmonary artery, on the pressure drop across the TCPC. A 3D computational model of a total TCPC connection provided with a porous insert is developed and solved by finite volume method, under assumptions of steady, laminar, and Newtonian flows. The effects of the porous medium properties—porosity and permeability—across the connection, are analyzed. Compared to the no‐porous medium case, TCPC with the porous medium insert exhibits a maximum reduction of 27% in energy loss for the flow range studied. The porous medium used in TCPC connection lowers the energy dissipation by curtailing the flow recirculation zones across the connection. The influences of the diameter of the blood vessel, total cardiac output, and the thickness, permeability, and position of porous media on energy loss are analyzed. The criteria to select the porous medium properties and position for a given Fontan geometry are also determined.