Evaluation of hemodynamic performance of total cavopulmonary connection (TCPC) with porous inserts
- 27 November 2017
- journal article
- conference paper
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 34 (4) , e2937
Abstract
Infants born with univentricular heart disease undergo Fontan surgery to establish separate systemic and pulmonary circulations. This surgery results in better blood circulation across a single ventricle that supplies oxygenated blood to the body and passively returns venous blood to the lungs through the total cavopulmonary connection (TCPC). Reducing the pressure drop across the TCPC during Fontan circulation helps in reducing the work load of univentricular heart, and various designs have been proposed for this purpose. The goal of this work is to analyze the effect of placing a porous insert at an appropriate position in the pulmonary artery, on the pressure drop across the TCPC. A 3D computational model of a total TCPC connection provided with a porous insert is developed and solved by finite volume method, under assumptions of steady, laminar, and Newtonian flows. The effects of the porous medium properties—porosity and permeability—across the connection, are analyzed. Compared to the no‐porous medium case, TCPC with the porous medium insert exhibits a maximum reduction of 27% in energy loss for the flow range studied. The porous medium used in TCPC connection lowers the energy dissipation by curtailing the flow recirculation zones across the connection. The influences of the diameter of the blood vessel, total cardiac output, and the thickness, permeability, and position of porous media on energy loss are analyzed. The criteria to select the porous medium properties and position for a given Fontan geometry are also determined.Keywords
This publication has 20 references indexed in Scilit:
- Experimental characterization of powered Fontan hemodynamics in an idealized total cavopulmonary connection modelExperiments in Fluids, 2013
- Four decades of Fontan palliationNature Reviews Cardiology, 2010
- Effect of variable permeability porous medium inter-connectors on the thermo-hydraulics of heat exchanger modelled as porous mediaInternational Journal of Heat and Mass Transfer, 2007
- Introduction of a New Optimized Total Cavopulmonary ConnectionThe Annals of Thoracic Surgery, 2007
- Effects of Exercise and Respiration on Hemodynamic Efficiency in CFD Simulations of the Total Cavopulmonary ConnectionAnnals of Biomedical Engineering, 2006
- Porous Medium Interconnector Effects on the Thermohydraulics of Near-Compact Heat Exchangers Treated as Porous MediaJournal of Heat Transfer, 2006
- Cardiac transplantation after the Fontan or Glenn procedureJACC, 2004
- In vitro flow experiments for determination of optimal geometry of total cavopulmonary connection for surgical repair of children with functional single ventricleJACC, 1996
- A numerical fluid mechanical study of repaired congenital heart defects. Application to the total cavopulmonary connectionJournal of Biomechanics, 1996
- Surgical repair of tricuspid atresiaThorax, 1971